The overall performance of a novel semi-transparent photovoltaic window with passive radiative cooling coating - A comparative study

被引:4
|
作者
Wang, Wanting [1 ]
Yang, Hongxing [2 ]
Xiang, Changying [1 ]
机构
[1] Hong Kong Univ Sci & Technol, Div Integrat Syst & Design, Hong Kong, Peoples R China
[2] Hong Kong Polytech Univ, Div Bldg Environm & Energy Engn, Hong Kong, Peoples R China
关键词
Building integrated photovoltaics; Passive radiative cooling; Semi-transparent PV; Color rendering index; Solar energy; ENERGY; PV; GLAZINGS; BIPV;
D O I
10.1016/j.enbuild.2024.114433
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Semi-transparent photovoltaic (STPV) glazing is a promising building integrated photovoltaic (BIPV) technology for converting traditional windows into on-site energy-producing building components. Besides electricity generation, there is also an urgent demand to enhance the thermal management of STPV glazing. Passive radioactive cooling paint is an emerging nanomaterials technology that shows great potential to reduce the painted surface temperature. Aiming to further promote the PV window's energy efficiency, this study designed and investigated a novel coated semi-transparent photovoltaic (CSTPV) glazing supplemented with highly transparent passive radiative cooling coating. In addition, the STPV/CSTPV's impacts on indoor visual environments were investigated, especially on the rarely studied aspect of interior colour rendering performance. This paper employs a combination of numerical simulation and experimental measurements to comprehensively assess these innovative glass systems in terms of electricity generation, thermal performance, daylighting efficiency, and the impact of color on the indoor environment. The results indicate that the CSTPV windows can significantly reduce the heat gain rate by about 15 % and achieve excellent electricity generation, with an annual output approximately 3 % higher than that of STPV windows. Despite the radiative cooling coating, CSTPV glazing maintains a level of daylight illumination comparable to that of STPV glazing, with glare levels remaining within acceptable limits. Furthermore, the study emphasizes the effects of CSTPV and STPV on the indoor Color Rendering Index (CRI) and Correlated Color Temperature (CCT) performance. All samples measured have CCT values within the range of neutral light, and CRI values exceeding 96, demonstrating satisfactory high-quality indoor lighting conditions. This research shows that CSTPV and STPV glass technologies not only significantly enhance the energy efficiency of buildings but also provide a scientific foundation for sustainable development in architectural design.
引用
收藏
页数:11
相关论文
共 50 条
  • [21] Analysis of thermal and electrical performance of semi-transparent photovoltaic (PV) module
    Park, K. E.
    Kang, G. H.
    Kim, H. I.
    Yu, G. J.
    Kim, J. T.
    ENERGY, 2010, 35 (06) : 2681 - 2687
  • [22] Experimental and numerical study on the annual performance of semi-transparent photovoltaic glazing in different climate zones
    Wu, Zhenghong
    Zhang, Ling
    Wu, Jing
    Liu, Zhongbing
    ENERGY, 2022, 240
  • [23] Comparison of the overall energy performance of semi-transparent photovoltaic windows and common energy-efficient windows in Hong Kong
    Zhang, Weilong
    Lu, Lin
    Peng, Jinqing
    Song, Aotian
    ENERGY AND BUILDINGS, 2016, 128 : 511 - 518
  • [24] Experimental and theoretical study on the performance of semi-transparent photovoltaic glazing facade under shaded conditions
    Wu, Jing
    Zhang, Ling
    Liu, Zhongbing
    Luo, Yongqiang
    Wu, Zhenghong
    Wang, Pengcheng
    ENERGY, 2020, 207 (207)
  • [25] Daylight performance of perimeter office facades utilizing semi-transparent photovoltaic windows: a simulation study
    Kapsis, K.
    Dermardiros, V.
    Athienitis, A. K.
    6TH INTERNATIONAL BUILDING PHYSICS CONFERENCE (IBPC 2015), 2015, 78 : 334 - 339
  • [26] Experimental and simulation study on the thermoelectric performance of semi-transparent crystalline silicon photovoltaic curtain walls
    Yao, Longyu
    Zhang, Wenjie
    Huang, Fengcheng
    Zhao, Rui
    Tang, Kai
    JOURNAL OF BUILDING ENGINEERING, 2024, 90
  • [27] Performance evaluation of a semi-transparent cells filtered concentrated photovoltaic/thermal system
    Ma, Yu
    Han, Xinyue
    Chen, Zhuo
    Zheng, Dengming
    APPLIED THERMAL ENGINEERING, 2025, 266
  • [28] Comparative study of the thermal and power performances of a semi-transparent photovoltaic facade under different ventilation modes
    Peng, Jinqing
    Lu, Lin
    Yang, Hongxing
    Ma, Tao
    APPLIED ENERGY, 2015, 138 : 572 - 583
  • [29] All-day continuous power generation: Integrating radiative cooling with semi-transparent photovoltaic cells filtered concentrated photovoltaic-thermoelectric generator system
    Lai, Peigen
    Han, Xinyue
    Chen, Xu
    Huang, Ju
    SOLAR ENERGY, 2025, 287
  • [30] Developing a method and simulation model for evaluating the overall energy performance of a ventilated semi-transparent photovoltaic double-skin facade
    Peng, Jinqing
    Curcija, Dragan C.
    Lu, Lin
    Selkowitz, Stephen E.
    Yang, Hongxing
    Mitchell, Robin
    PROGRESS IN PHOTOVOLTAICS, 2016, 24 (06): : 781 - 799