A low noise and low power device composed of electrode and CD ASIC for neural and other vital signals recording

被引:0
|
作者
Sun, Jianhui [1 ,2 ,3 ,4 ]
Wang, Zibin [1 ]
Wang, Tongxi [5 ]
Liu, Guozhu [6 ]
Tian, Jiangwei [7 ]
机构
[1] School of Physics and Electronics, Shandong Normal University, Jinan,250014, China
[2] State Key Laboratory of Transducer Technology, Institute of Electronics, Chinese Academy of Sciences, Beijing,100190, China
[3] Shandong Key Laboratory of Medical Physics and Image Processing, School of Physics and Electronics, Shandong Normal University, Jinan,250014, China
[4] Center of Light Manipulations and Applications & Shandong Provincial Key Laboratory of Optics and Photonic Device, School of Physics and Electronics, Shandong Normal University, Jinan,250014, China
[5] Interuniversity Microelectronics Centre, Leuven, Belgium
[6] School of Electronic Science and Engineering, Southeast University, Nanjing,210096, China
[7] State Key Laboratory of Natural Medicines, Jiangsu Key Laboratory of TCM Evaluation and Translation Research, School of Traditional Chinese Pharmacy, China Pharmaceutical University, Nanjing,211198, China
关键词
Nanoparticles - Electroencephalography - Signal to noise ratio - Graphene - Polypyrroles - Analog to digital conversion - Energy utilization - Application specific integrated circuits - Biomedical signal processing - Electrocardiography;
D O I
暂无
中图分类号
学科分类号
摘要
In this paper, to effectively record the electroencephalogram (EEG) and other body-vital signals of the healthy volunteer, a low-noise and low-power device was developed. The proposed device consisted of a novel convenient, reliable and sensitive electrode realized by an Ag/AgCl dry-contact electrode coated with nano-composites and a novel post-electrode chopper digitizer (CD). The CD consisted of a low noise and low power chopping pre-amplifier with gain and band-width (BW) adjustable abilities and an intermediate speed and low power successive approximation register-analog digital converter (SAR-ADC). First, using the front-end electrode, the neural signal was received from the brain scalp; second, using the CD, the amplified analog voltage outputting from the chopping pre-amplifier was converted into digital sequences using the SAR-ADC. Testing results showed that the contact resistance between the electrode and the brain scalp was optimized to about 300.00 kΩ, as the electrode was coated with polypyrrole-graphene nano-particles. And, the linear relevancy between the electrode and the traditional wet-contact electrode was more than 93%. Finally, the CD was manufactured with CMOS technology (SmicRF180NM 1Poly6M) under a supply voltage of 1.0 V. Testing results of the CD showed that: (1) the CD achieved an inputting-referred noise of 0.40 μV root-mean-square (RMS) in 0.18–200 Hz, the energy consumption was 3.40 μW for one chopping pre-amplifier, 200 μW for SAR-ADC, etc.; (2) the SAR-ADC achieved an effective number of bits (ENOB) of 9.96-bits under conversion rate reaching 1.00 MSps, the signal noise ratio (SNR) was 60.97 dB, etc. The designed device could satisfy recording for EEG signals in μV level, also, the device could be used for detecting electrocardiography (EKG) signals in mV level. So, the low noise and low power device worked well for recording micro neural signals, and suitable for constructing reliable portable or wearable pervasive bio-devices used for multiple body-vital signals too. © 2021 Elsevier B.V.
引用
收藏
相关论文
共 50 条
  • [1] A low noise and low power device composed of electrode and CD ASIC for neural and other vital signals recording
    Sun, Jianhui
    Wang, Zibin
    Wang, Tongxi
    Liu, Guozhu
    Tian, Jiangwei
    SENSORS AND ACTUATORS A-PHYSICAL, 2021, 324
  • [2] Low-power low noise amplifier with tunable band for neural signal recording
    Kmon, P.
    Grybos, P.
    MIXDES 2008: PROCEEDINGS OF THE 15TH INTERNATIONAL CONFERENCE ON MIXED DESIGN OF INTEGRATED CIRCUITS AND SYSTEMS, 2008, : 255 - 260
  • [3] A Low-Power Low-Noise Bioamplifier for Multielectrode Neural Recording Systems
    Quadir, Md Shahed Enamul
    Haider, Mohammad Rafiqul
    Massoud, Yehia
    2012 IEEE INTERNATIONAL SYMPOSIUM ON CIRCUITS AND SYSTEMS (ISCAS 2012), 2012, : 2557 - 2560
  • [4] Design of low noise and low power Chopper Stabilized Amplifier for Neural Recording Applications
    Zhou, Lv-chen
    Li, Zun-Chao
    Li, Jia
    Xiong, Qi
    2018 14TH IEEE INTERNATIONAL CONFERENCE ON SOLID-STATE AND INTEGRATED CIRCUIT TECHNOLOGY (ICSICT), 2018, : 1442 - 1444
  • [5] A low-power low-noise CMOS amplifier for neural recording applications
    Harrison, RR
    Charles, C
    IEEE JOURNAL OF SOLID-STATE CIRCUITS, 2003, 38 (06) : 958 - 965
  • [6] Low-Power Low-Noise Versatile Amplifier for Neural Signal Recording
    Kmon, Piotr
    ICSES 2008 INTERNATIONAL CONFERENCE ON SIGNALS AND ELECTRONIC SYSTEMS, CONFERENCE PROCEEDINGS, 2008, : 141 - 146
  • [7] A low-power, low-noise CMOS amplifier for neural recording applications
    Harrison, RR
    2002 IEEE INTERNATIONAL SYMPOSIUM ON CIRCUITS AND SYSTEMS, VOL V, PROCEEDINGS, 2002, : 197 - 200
  • [8] A low noise, low power, high dynamic range amplifier-filter circuit for recording neural signals using multielectrode arrays
    Rydygier, Przemyslaw
    Fiutowski, Tomasz
    Dabrowski, Wladyslaw
    PRZEGLAD ELEKTROTECHNICZNY, 2010, 86 (11A): : 64 - 68
  • [9] A 700mV Low Power Low Noise Implantable Neural Recording System Design
    An, Guanglei
    Hutchens, Chriswell
    Rennaker, Robert L., II
    2014 36TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2014, : 6557 - 6560
  • [10] A Low-Power, Low-Noise Neural Recording Amplifier for Implantable Biomedical Devices
    Kim, Hyung Seok
    Cha, Hyouk-Kyu
    2016 INTERNATIONAL SOC DESIGN CONFERENCE (ISOCC), 2016, : 275 - 276