Compact Active Vibration Isolation and Tilt Stabilization for a Portable High-Precision Atomic Gravimeter

被引:7
|
作者
Oon F.E. [1 ]
Dumke R. [1 ,2 ]
机构
[1] Centre for Quantum Technologies, National University of Singapore, 3 Science Drive 2, Singapore
[2] Division of Physics and Applied Physics, Nanyang Technological University, 21 Nanyang Link, Singapore
基金
新加坡国家研究基金会;
关键词
Adaptive control systems - Atoms - Feedback control - Ground state - Horizontal wells - Laser beams - Stabilization;
D O I
10.1103/PhysRevApplied.18.044037
中图分类号
学科分类号
摘要
In high-precision atomic gravimeters, a rest mass is needed to provide a gravity reference, which is typically the retro-reflecting mirror of the Raman laser beams that address the two hyperfine ground states of the specific free-falling atomic test mass. We construct a compact active feedback control system for the retro-reflecting mirror that provides vibration isolation in the vertical axis as well as two-rotation stabilization in the horizontal plane. The active feedback control provides vertical vibration reduction of up to a factor of 300 in the frequency range of 0.03 to 10 Hz and tilt stabilization of approximately ±1μrad in a noisy laboratory environment. This system enables high-precision gravity measurements on a portable gravimeter with sensitivity reaching 6.4×10-8g/Hz and resolution of 2.8×10-9g after an integration time of 4000 s. © 2022 American Physical Society.
引用
收藏
相关论文
共 50 条
  • [41] HIGH-PRECISION TILT STAGE FOR THE HIGH-VOLTAGE ELECTRON-MICROSCOPE
    TURNER, JN
    BARNARD, DP
    MATUSZEK, G
    SEE, CW
    ULTRAMICROSCOPY, 1988, 26 (04) : 337 - 344
  • [42] A portable laser system for high-precision atom interferometry experiments
    Schmidt, M.
    Prevedelli, M.
    Giorgini, A.
    Tino, G. M.
    Peters, A.
    APPLIED PHYSICS B-LASERS AND OPTICS, 2011, 102 (01): : 11 - 18
  • [43] A portable laser system for high-precision atom interferometry experiments
    M. Schmidt
    M. Prevedelli
    A. Giorgini
    G. M. Tino
    A. Peters
    Applied Physics B, 2011, 102 : 11 - 18
  • [44] An Active Control Method for Vibration Isolation of Precision Equipments
    Yu, Lianqing
    Rao, Cheng
    Du, Lizhen
    2009 ISECS INTERNATIONAL COLLOQUIUM ON COMPUTING, COMMUNICATION, CONTROL, AND MANAGEMENT, VOL III, 2009, : 368 - 371
  • [45] Active structural damping in high-precision equipment
    Vervoordeldonk, M. J.
    van Eijk, J.
    Roozen, N. B.
    PROCEEDINGS OF ISMA2006: INTERNATIONAL CONFERENCE ON NOISE AND VIBRATION ENGINEERING, VOLS 1-8, 2006, : 573 - +
  • [46] Development of Active Vibration Isolation System for Precision Machines
    Li, H. Z.
    Lin, W. J.
    Yang, G. L.
    FOURTH INTERNATIONAL CONFERENCE ON EXPERIMENTAL MECHANICS, 2010, 7522
  • [47] Sensor fusion for active vibration isolation in precision equipment
    Tjepkema, D.
    van Dijk, J.
    Soemers, H. M. J. R.
    JOURNAL OF SOUND AND VIBRATION, 2012, 331 (04) : 735 - 749
  • [48] High-precision interferometric vibration measurement with squeezed light
    Yu, Mengwei
    Gewecke, Pascal
    Schnabel, Roman
    Rembe, Christian
    TM-TECHNISCHES MESSEN, 2023, 90 : 79 - 84
  • [49] High-Precision Positioning of Laser Beams for Vibration Measurements
    Marinescu, Olguta
    Epureanu, Bogdan I.
    JOURNAL OF VIBRATION AND ACOUSTICS-TRANSACTIONS OF THE ASME, 2014, 136 (01):
  • [50] HIGH-PRECISION POSITIONING OF LASER BEAMS FOR VIBRATION MEASUREMENTS
    Marinescu, Olguta
    Epureanu, Bogdan I.
    PROCEEDINGS OF THE ASME TURBO EXPO: TURBINE TECHNICAL CONFERENCE AND EXPOSITION, 2013, VOL 4, 2013,