Compact Active Vibration Isolation and Tilt Stabilization for a Portable High-Precision Atomic Gravimeter

被引:7
|
作者
Oon F.E. [1 ]
Dumke R. [1 ,2 ]
机构
[1] Centre for Quantum Technologies, National University of Singapore, 3 Science Drive 2, Singapore
[2] Division of Physics and Applied Physics, Nanyang Technological University, 21 Nanyang Link, Singapore
基金
新加坡国家研究基金会;
关键词
Adaptive control systems - Atoms - Feedback control - Ground state - Horizontal wells - Laser beams - Stabilization;
D O I
10.1103/PhysRevApplied.18.044037
中图分类号
学科分类号
摘要
In high-precision atomic gravimeters, a rest mass is needed to provide a gravity reference, which is typically the retro-reflecting mirror of the Raman laser beams that address the two hyperfine ground states of the specific free-falling atomic test mass. We construct a compact active feedback control system for the retro-reflecting mirror that provides vibration isolation in the vertical axis as well as two-rotation stabilization in the horizontal plane. The active feedback control provides vertical vibration reduction of up to a factor of 300 in the frequency range of 0.03 to 10 Hz and tilt stabilization of approximately ±1μrad in a noisy laboratory environment. This system enables high-precision gravity measurements on a portable gravimeter with sensitivity reaching 6.4×10-8g/Hz and resolution of 2.8×10-9g after an integration time of 4000 s. © 2022 American Physical Society.
引用
收藏
相关论文
共 50 条
  • [21] Environmental Microvibration Analysis Method for Vibration Isolation Research in High-Precision Laboratories
    Cheng, Yang
    Lu, Kangyi
    Huang, Qiuju
    Ding, Feng
    Song, Chunyu
    BUILDINGS, 2024, 14 (05)
  • [22] A Method for Diagnosing the Performance of the Dropping Mechanism in the High-Precision Absolute Gravimeter
    Chen, Yicong
    Wen, Yi
    Wu, Kang
    Wang, Lijun
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2023, 72
  • [23] Measurement of ground borne vibrations for foundation design and vibration isolation of a high-precision instrument
    Ulgen, D.
    Ertugrul, O. L.
    Ozkan, M. Y.
    MEASUREMENT, 2016, 93 : 385 - 396
  • [24] Compact trimming design of a high-precision reference
    任国栋
    赵世芳
    蒲忠胜
    魏智强
    Journal of Semiconductors, 2014, 35 (04) : 138 - 141
  • [25] High-precision compact-thermal models
    Sabry, MN
    IEEE TRANSACTIONS ON COMPONENTS AND PACKAGING TECHNOLOGIES, 2005, 28 (04): : 623 - 629
  • [26] COMPACT HIGH-PRECISION GUARDED VOLT BOX
    SCHARLE, CR
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 1971, IM20 (04) : 257 - &
  • [27] Compact trimming design of a high-precision reference
    任国栋
    赵世芳
    蒲忠胜
    魏智强
    Journal of Semiconductors, 2014, (04) : 138 - 141
  • [28] Compact trimming design of a high-precision reference
    Ren Guodong
    Zhao Shifang
    Pu Zhongshen
    Wei Zhiqiang
    JOURNAL OF SEMICONDUCTORS, 2014, 35 (04)
  • [29] Investigation on Micro-Vibration Test and Image Stabilization of a High-Precision Space Optical Payload
    Li, Zhenchuang
    Guo, Junli
    Qin, Tao
    Wang, Jin
    Peng, Jinjin
    Wu, Yun
    Jing, Zijian
    Zhang, Hongming
    Hou, Jinge
    Qi, Bo
    APPLIED SCIENCES-BASEL, 2025, 15 (03):
  • [30] Design and tests of the high-precision temperature control and measurement system in the digital gravimeter
    Qin Pei
    Liang LianZhong
    Tao ZhaoMing
    Huang Tao
    Liu Yu
    CHINESE JOURNAL OF GEOPHYSICS-CHINESE EDITION, 2019, 62 (10): : 3665 - 3674