Free flap perfusion prediction by laser doppler flowmetry based time series analysis

被引:0
|
作者
Kodama H. [1 ]
Ishida K. [1 ]
Hirayama H. [1 ]
Kishi K. [1 ]
Miyawaki T. [1 ]
机构
[1] Department of Plastic and Reconstructive surgery, The Jikei University School of Medicine
关键词
ARMA; free flap; laser doppler flowmetry; LSTM; time series analysis;
D O I
10.11239/jsmbe.Annual59.626
中图分类号
学科分类号
摘要
Flap ischemia and consecutive flap loss is an innate complication in reconstructive free flap surgery. With the development of machine learning, time series analysis based flap failure prediction has become possible. With the laser doppler flowmetry pocket device (PocketLDF®) by JMS it has become possible to measure skin perfusion every second. In this trial skin perfusion in addition to blood pressure, pulse and respiratory rate were measured in 3 patients and flap failure prediction based on the Auto-Regressive Moving Average (ARMA) model and the Long Short Term Memory (LSTM) network was conducted. Accurate perfusion prediction with the ARMA model for stationary processes and with the LSTM network for non-stationary processes was possible. In comparison with real time observation by the attending doctor, the ARMA model was able to predict flap ischemia ahead of time. © 2021, Japan Soc. of Med. Electronics and Biol. Engineering. All rights reserved.
引用
收藏
页码:628 / 630
页数:2
相关论文
共 50 条
  • [41] PREDICTION OF SKIN FLAP NECROSIS - A COMPARATIVE-STUDY BETWEEN LASER DOPPLER FLOWMETRY AND FLUORESCEIN TEST IN A RAT MODEL
    HEDEN, P
    JURELL, G
    ARNANDER, C
    ANNALS OF PLASTIC SURGERY, 1986, 17 (06) : 485 - 488
  • [42] QUANTITATION OF THYROID-HORMONE EFFECT ON SKIN PERFUSION BY LASER DOPPLER FLOWMETRY
    WEISS, M
    MILMAN, B
    ROSEN, B
    ZIMLICHMAN, R
    JOURNAL OF CLINICAL ENDOCRINOLOGY & METABOLISM, 1993, 76 (03): : 680 - 682
  • [43] Modelling laser-Doppler perfusion flowmetry of iontophoresis diffusion, applied to preeclampsia
    de Mul, F. F. M.
    Blaauw, J.
    Aarnoudse, J. G.
    Smit, A. J.
    Rakhorst, G.
    JOURNAL OF VASCULAR RESEARCH, 2006, 43 : 47 - 47
  • [44] THE SIGNIFICANCE OF PROBE DESIGN IN EVALUATION OF COLONIC PERFUSION WITH LASER-DOPPLER FLOWMETRY
    KROHGSORENSEN, K
    LINE, PD
    KVERNEBO, K
    SCANDINAVIAN JOURNAL OF GASTROENTEROLOGY, 1993, 28 (05) : 381 - 386
  • [45] ASSESSMENT OF MYOCARDIAL PERFUSION IN THE EMPTY BEATING PORCINE HEART WITH LASER DOPPLER FLOWMETRY
    AHN, HC
    EKROTH, R
    HEDENMARK, J
    NILSSON, GE
    SVEDJEHOLM, R
    CARDIOVASCULAR RESEARCH, 1988, 22 (10) : 719 - 725
  • [46] Pulsed-laser Doppler flowmetry provides basis for deep perfusion probing
    Kolkman, RGM
    Hondebrink, E
    Bolt, RA
    Steenbergen, W
    de Mul, FFM
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2001, 72 (11): : 4242 - 4244
  • [47] Laser doppler flowmetry and transcutaneous oximetry, complementary methods to evaluate skin perfusion
    Potocnik, Ivana
    Potocnik, Nejka
    ACTA PHYSIOLOGICA, 2023, 239
  • [48] Bispectral analysis in Laser Doppler Flowmetry signal processing
    Alexopoulos, V
    Kollias, S
    PROCEEDINGS OF THE 19TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOL 19, PTS 1-6: MAGNIFICENT MILESTONES AND EMERGING OPPORTUNITIES IN MEDICAL ENGINEERING, 1997, 19 : 1134 - 1137
  • [49] DOES LASER-DOPPLER FLOWMETRY PROVIDE A QUANTITATIVE MEASURE OF HEPATIC PERFUSION
    WHEATLEY, AM
    AMERICAN JOURNAL OF PHYSIOLOGY, 1994, 266 (05): : G960 - G961
  • [50] PREDICTION OF SAMPLING DEPTH AND PHOTON PATHLENGTH IN LASER-DOPPLER FLOWMETRY
    JAKOBSSON, A
    NILSSON, GE