Free flap perfusion prediction by laser doppler flowmetry based time series analysis

被引:0
|
作者
Kodama H. [1 ]
Ishida K. [1 ]
Hirayama H. [1 ]
Kishi K. [1 ]
Miyawaki T. [1 ]
机构
[1] Department of Plastic and Reconstructive surgery, The Jikei University School of Medicine
关键词
ARMA; free flap; laser doppler flowmetry; LSTM; time series analysis;
D O I
10.11239/jsmbe.Annual59.626
中图分类号
学科分类号
摘要
Flap ischemia and consecutive flap loss is an innate complication in reconstructive free flap surgery. With the development of machine learning, time series analysis based flap failure prediction has become possible. With the laser doppler flowmetry pocket device (PocketLDF®) by JMS it has become possible to measure skin perfusion every second. In this trial skin perfusion in addition to blood pressure, pulse and respiratory rate were measured in 3 patients and flap failure prediction based on the Auto-Regressive Moving Average (ARMA) model and the Long Short Term Memory (LSTM) network was conducted. Accurate perfusion prediction with the ARMA model for stationary processes and with the LSTM network for non-stationary processes was possible. In comparison with real time observation by the attending doctor, the ARMA model was able to predict flap ischemia ahead of time. © 2021, Japan Soc. of Med. Electronics and Biol. Engineering. All rights reserved.
引用
收藏
页码:628 / 630
页数:2
相关论文
共 50 条
  • [21] Pulsed laser-Doppler flowmetry for monitoring deep perfusion
    Kolkman, RGM
    Hondebrink, E
    Bolt, RA
    Steenbergen, W
    de Mul, FFM
    HYBRID AND NOVEL IMAGING AND NEW OPTICAL INSTRUMENTATION FOR BIOMEDICAL APPLICATIONS, 2001, 4434 : 204 - 207
  • [22] Measurement of blood perfusion in the dental pulp with laser Doppler flowmetry
    Firestone, AR
    Wheatley, AM
    Thüer, UW
    INTERNATIONAL JOURNAL OF MICROCIRCULATION-CLINICAL AND EXPERIMENTAL, 1997, 17 (06): : 298 - 304
  • [23] LASER DOPPLER FLOWMETRY AND LASER PHOTOMETRY FOR MONITORING FREE FLAPS
    SVENSSON, H
    PETTERSSON, H
    SVEDMAN, P
    SCANDINAVIAN JOURNAL OF PLASTIC AND RECONSTRUCTIVE SURGERY AND HAND SURGERY, 1985, 19 (03): : 245 - 249
  • [24] Automatic full field analysis of perfusion images gained by scanning laser Doppler flowmetry
    Michelson, G
    Welzenbach, J
    Pal, I
    Harazny, J
    BRITISH JOURNAL OF OPHTHALMOLOGY, 1998, 82 (11) : 1294 - 1300
  • [25] Physiological studies using laser Doppler flowmetry to compare blood flow to the zones of the free TRAM flap
    Hallock, GG
    ANNALS OF PLASTIC SURGERY, 2001, 47 (03) : 229 - 233
  • [26] The future of free flap monitoring by laser continuous doppler flowmetry: A prospective assessment in consecutive 71 patients
    Kodama, Hiroki
    Ishida, Katsuhiro
    Hirayama, Haruyuki
    Orgun, Doruk
    Kawashima, Kazuho
    Nikkhah, Dariush
    May, James
    Kyriacou, Panicos A.
    Miyawaki, Takeshi
    JPRAS OPEN, 2025, 43 : 140 - 152
  • [27] Free flap monitoring using simultaneous non-invasive laser Doppler flowmetry and tissue spectrophotometry
    Hölzle, F
    Loeffelbein, DJ
    Nolte, D
    Wolff, KD
    JOURNAL OF CRANIO-MAXILLOFACIAL SURGERY, 2006, 34 (01) : 25 - 33
  • [28] ZONES OF THE LOWER TRANSVERSE RECTUS-ABDOMINIS MUSCULOCUTANEOUS FLAP BASED ON LASER DOPPLER FLOWMETRY
    HALLOCK, GG
    ANNALS OF PLASTIC SURGERY, 1992, 29 (02) : 117 - 121
  • [29] HUMAN BRONCHIAL PERFUSION EVALUATED WITH ENDOSCOPIC LASER-DOPPLER FLOWMETRY
    SUNDSET, A
    HANSEN, G
    HAANAES, OC
    LINE, PD
    KVERNEBO, K
    INTERNATIONAL JOURNAL OF MICROCIRCULATION-CLINICAL AND EXPERIMENTAL, 1993, 13 (03): : 233 - 245
  • [30] LASER-DOPPLER FLOWMETRY - A NONINVASIVE METHOD FOR MICROVASCULAR PERFUSION MEASUREMENTS
    OBERG, PA