Optical hydrogen peroxide sensor for measurements in flow

被引:0
|
作者
Tjell, Anders Ø. [1 ]
Jud, Barbara [1 ]
Schaller-Ammann, Roland [2 ]
Mayr, Torsten [1 ]
机构
[1] Institute of Analytical Chemistry and Food Chemistry, Graz University of Technology, Stremayrgasse 9/II, Graz,8010, Austria
[2] HEALTH – Institute for Biomedical Research and Technologies, Joanneum Research Forschungsgesellschaft m.b.H, Neue Stiftingtalstraße 2, Graz,8010, Austria
基金
欧盟地平线“2020”;
关键词
Ascorbic acid - Batch reactors - Catalyst activity - Glucose oxidase - Glucose sensors - Hydrogen peroxide - Oxidation - Ruthenium compounds - Silica - Sodium compounds;
D O I
暂无
中图分类号
学科分类号
摘要
An optical hydrogen peroxide (H2O2) sensor is presented. The sensor is based on catalytic degradation of H2O2 and the detection of produced oxygen (O2) with a phosphorescent sensor. A novel aspect of the sensor is removal O2 from the analyte solution in flow. This allows the use of a more sensitive O2 sensor. Thereby, a better resolution at lower H2O2 concentrations is achieved. Sensor spots are integrated in a flow-through cell, and H2O2 is measured in flow between 10 and 80 µL/min. The catalytic activities of previously reported catalyst are tested. RuO2 and silica supported platinum nanoparticles are applied in the sensor with limit of detections of 0.16 and 0.17 µM H2O2, respectively. The sensor can measure reliably between 1 and 200 µM H2O2. The concentration range can be extended to 1000 µM H2O2 by exchanging the O2 sensor. Interfering species (NaONOO, NaOCl, t-BuOOH, and ascorbic acid) are tested and show only minor cross-sensitivities. The sensor is applied at-line in a model batch reactor with glucose oxidase to showcase production of H2O2 from glucose. © 2023 The Authors
引用
收藏
相关论文
共 50 条
  • [41] NICKELOCENE-MEDIATING SENSOR FOR HYDROGEN-PEROXIDE BASED ON BIOELECTROCATALYTIC REDUCTION OF HYDROGEN-PEROXIDE
    LIU, HY
    QIAN, JH
    LIU, YC
    YU, TY
    DENG, JQ
    ANALYTICAL PROCEEDINGS, 1995, 32 (11): : 475 - 477
  • [42] Cross-correlation techniques applied to optical sensor for respiratory flow measurements
    Sigaki, NA
    Werneck, MM
    dos Santos, PAM
    PROCEEDINGS OF THE 22ND ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-4, 2000, 22 : 2790 - 2791
  • [43] Flow cell with hybrid LPG and FBG optical fiber sensor for refractometric measurements
    Baldini, F.
    Brenci, M.
    Chiavaioli, F.
    Falciai, R.
    Trono, C.
    21ST INTERNATIONAL CONFERENCE ON OPTICAL FIBER SENSORS, 2011, 7753
  • [44] OPTICAL FIBER HYDROGEN SENSOR
    BUTLER, MA
    APPLIED PHYSICS LETTERS, 1984, 45 (10) : 1007 - 1009
  • [45] Flow injection analysis of hydrogen peroxide in disinfectants
    Harms, D
    Than, R
    Krebs, B
    Karst, U
    FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1999, 364 (1-2): : 184 - 188
  • [46] Hydrogen peroxide and metabolic coronary flow regulation
    Canty, John M., Jr.
    Iyer, Vijay S.
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2007, 50 (13) : 1279 - 1281
  • [47] Anodic generation of hydrogen peroxide in continuous flow
    Pangotra, Dhananjai
    Csepei, Lenard-Istvan
    Roth, Arne
    Sieber, Volker
    Vieira, Luciana
    GREEN CHEMISTRY, 2022, 24 (20) : 7931 - 7940
  • [48] Electrocatalytic Sensor for Hydrogen Peroxide Based on Immobilized Benzoquinone
    Laroussi, Arwa
    Raouafi, Noureddine
    Mirsky, Vladimir M.
    ELECTROANALYSIS, 2021, 33 (09) : 2062 - 2070
  • [49] Calorimetric Sensor for Use in Hydrogen Peroxide Aqueous Solutions
    Porkovich, A. J.
    Arnold, M. D.
    Kouzmina, G.
    Hingley, B.
    Dowd, A.
    Cortie, M. B.
    SENSOR LETTERS, 2011, 9 (02) : 695 - 697
  • [50] Electrochemical Hydrogen Peroxide Sensor Based on Macroporous Silicon
    Al-Hardan, Naif H.
    Hamid, Muhammad Azmi Abdul
    Shamsudin, Roslinda
    AL-Khalqi, Ensaf Mohammed
    Keng, Lim Kar
    Ahmed, Naser M.
    SENSORS, 2018, 18 (03):