Oxygen Monitor to Study Vascularization of Medical Devices

被引:0
|
作者
Najdahmadi A. [1 ]
Gurlin R. [2 ]
Zhang M. [2 ]
Lakey J.R.T. [2 ,3 ]
Botvinick E. [1 ,2 ,3 ]
机构
[1] Department of Materials Science and Engineering, University of California Irvine, Irvine
[2] Department of Biomedical Engineering, University of California Irvine, Irvine
[3] Department of Surgery, University of California Irvine, Irvine
来源
MRS Advances | 2020年 / 5卷 / 18-19期
关键词
Mammals - Partial pressure - Silicones;
D O I
10.1557/ADV.2020.97
中图分类号
学科分类号
摘要
Prevascularized medical devices can improve cell therapy. Such devices may replace whole organ transplantation with hosting only the necessary therapeutic cells. We have developed a noninvasive optical technology to study the vascularization into such medical devices. In our technique, oxygen partial pressure within a device is monitored by Oxygen Sensitive Tubes (OSTs), comprising oxygen permeable silicone tubing with inner luminal surfaces coated by an oxygen-sensitive porphyrin dye. OSTs were placed within a PDMS device and transplanted into the subcutaneous space of athymic nude mice. An optical probe placed over the skin excites the OSTs with a pulse of light and detects the luminescent lifetime of emitted light, which is uniquely related to oxygen partial pressure. Furthermore, we developed a Dynamic Inhalation Gas Test (DIGT) to determine the oxygen transport rate between the microvasculature and the device. DIGT works by monitoring oxygen partial pressure in a device following a step change in inhaled-gas oxygen content. We report DIGT oxygen dynamics measured intermittently over eight weeks. Our study shows DIGT dynamics are unique to each implant, supporting the important role of the host tissue response in the availability of oxygen over time. © 2020 Materials Research Society.
引用
收藏
页码:991 / 1000
页数:9
相关论文
共 50 条
  • [41] VASCULARIZATION OF THE CARPUS, A SYSTEMATIC STUDY
    KUHLMANN, JN
    GUERINSURVILLE, H
    BOABIGHI, A
    SURGICAL AND RADIOLOGIC ANATOMY, 1988, 10 (01) : 21 - 28
  • [42] A SYSTEMATIC STUDY OF THE VASCULARIZATION OF THE PANCREAS
    DONATINI, B
    SURGICAL AND RADIOLOGIC ANATOMY, 1990, 12 (03) : 173 - 180
  • [43] Medical devices as medical problems: The regulation of devices for clinical use
    Brown, J.H.U.
    1600, (11):
  • [44] MEDICAL DEVICES AS MEDICAL PROBLEMS - REGULATION OF DEVICES FOR CLINICAL USE
    BROWN, JHU
    BIOMEDICAL ENGINEERING, 1976, 11 (10) : 337 - 339
  • [45] STUDY ON VASCULARIZATION OF THE MUSCULUS SUPRASPINATUS
    LING, SC
    CHEN, CF
    WAN, RX
    SURGICAL AND RADIOLOGIC ANATOMY, 1990, 12 (03) : 2 - 4
  • [46] Exploration of oxygen-mediated disinfection of medical devices reveals a high sensitivity of Pseudomonas aeruginosa to elevated oxygen levels
    Cavallo, Francis M.
    Kommers, Richard
    Friedrich, Alexander W.
    Glasner, Corinna
    van Dijl, Jan Maarten
    SCIENTIFIC REPORTS, 2022, 12 (01)
  • [47] New study on the correlation between carbon dioxide concentration in the environment and radon monitor devices
    Shahrokhi, A.
    Burghele, B. D.
    Fabian, F.
    Kovacs, T.
    JOURNAL OF ENVIRONMENTAL RADIOACTIVITY, 2015, 150 : 57 - 61
  • [48] Exploration of oxygen-mediated disinfection of medical devices reveals a high sensitivity of Pseudomonas aeruginosa to elevated oxygen levels
    Francis M. Cavallo
    Richard Kommers
    Alexander W. Friedrich
    Corinna Glasner
    Jan Maarten van Dijl
    Scientific Reports, 12
  • [49] Numerical study of nitrogen desorption by rapid oxygen purge for a medical oxygen concentrator
    Chai, Siew Wah
    Kothare, Mayuresh V.
    Sircar, Shivaji
    ADSORPTION-JOURNAL OF THE INTERNATIONAL ADSORPTION SOCIETY, 2012, 18 (02): : 87 - 102
  • [50] Numerical study of nitrogen desorption by rapid oxygen purge for a medical oxygen concentrator
    Siew Wah Chai
    Mayuresh V. Kothare
    Shivaji Sircar
    Adsorption, 2012, 18 : 87 - 102