Oxygen Monitor to Study Vascularization of Medical Devices

被引:0
|
作者
Najdahmadi A. [1 ]
Gurlin R. [2 ]
Zhang M. [2 ]
Lakey J.R.T. [2 ,3 ]
Botvinick E. [1 ,2 ,3 ]
机构
[1] Department of Materials Science and Engineering, University of California Irvine, Irvine
[2] Department of Biomedical Engineering, University of California Irvine, Irvine
[3] Department of Surgery, University of California Irvine, Irvine
来源
MRS Advances | 2020年 / 5卷 / 18-19期
关键词
Mammals - Partial pressure - Silicones;
D O I
10.1557/ADV.2020.97
中图分类号
学科分类号
摘要
Prevascularized medical devices can improve cell therapy. Such devices may replace whole organ transplantation with hosting only the necessary therapeutic cells. We have developed a noninvasive optical technology to study the vascularization into such medical devices. In our technique, oxygen partial pressure within a device is monitored by Oxygen Sensitive Tubes (OSTs), comprising oxygen permeable silicone tubing with inner luminal surfaces coated by an oxygen-sensitive porphyrin dye. OSTs were placed within a PDMS device and transplanted into the subcutaneous space of athymic nude mice. An optical probe placed over the skin excites the OSTs with a pulse of light and detects the luminescent lifetime of emitted light, which is uniquely related to oxygen partial pressure. Furthermore, we developed a Dynamic Inhalation Gas Test (DIGT) to determine the oxygen transport rate between the microvasculature and the device. DIGT works by monitoring oxygen partial pressure in a device following a step change in inhaled-gas oxygen content. We report DIGT oxygen dynamics measured intermittently over eight weeks. Our study shows DIGT dynamics are unique to each implant, supporting the important role of the host tissue response in the availability of oxygen over time. © 2020 Materials Research Society.
引用
收藏
页码:991 / 1000
页数:9
相关论文
共 50 条
  • [32] Robust Medical Monitor Design
    Weimer, James
    Sokolsky, Oleg
    Lee, Insup
    2015 IEEE INTERNATIONAL CONFERENCE ON HEALTHCARE INFORMATICS (ICHI 2015), 2015, : 445 - 445
  • [33] Uses of Software Interfaces in the Study of Commercial Medical Devices
    Kozikowski, Raymond
    Winslow, Andrew
    Shang, Allan
    ANESTHESIA AND ANALGESIA, 2007, 105 : S105 - S106
  • [34] SMPTE STUDY OF AND RECOMMENDATIONS FOR MEDICAL DIAGNOSTIC DISPLAY DEVICES
    LISK, KG
    SMPTE JOURNAL, 1984, 93 (01): : 124 - 125
  • [35] A STUDY ON RADIATION STERILIZATION OF MEDICAL DEVICES IN THE SOUTH OF CHINA
    WEN, ZT
    LOU, RY
    LI, ML
    LIU, XQ
    LIN, NJ
    ZENG, MS
    RADIATION PHYSICS AND CHEMISTRY, 1993, 42 (4-6): : 641 - 643
  • [37] An Experimental Study Based on Surface Microtexture of Medical Devices
    Chen, Chaoda
    Shao, Xiaoqiang
    Guo, Junrong
    Yu, Zhuoyuan
    Chen, Ziyang
    Lu, Xuan
    Jiang, Zhansi
    COATINGS, 2024, 14 (07)
  • [38] Data sources: Use in the epidemiologic study of medical devices
    Torrence, ME
    EPIDEMIOLOGY, 2002, 13 (03) : S10 - S14
  • [39] TECHNIQUE FOR STUDYING ARTERIAL VASCULARIZATION OF BONE - APPLICATION TO STUDY OF VASCULARIZATION OF HUMERUS
    FISCHER, LP
    CARRET, JP
    GONON, GP
    DEMOURGUES, G
    CLERMONT, A
    INTERNATIONAL ORTHOPAEDICS, 1977, 1 (03) : 171 - 178
  • [40] Medical devices and medical training
    Todd, N. V.
    Gholkar, A.
    ANNALS OF THE ROYAL COLLEGE OF SURGEONS OF ENGLAND, 2008, 90 (08) : 709 - 710