Oxygen Monitor to Study Vascularization of Medical Devices

被引:0
|
作者
Najdahmadi A. [1 ]
Gurlin R. [2 ]
Zhang M. [2 ]
Lakey J.R.T. [2 ,3 ]
Botvinick E. [1 ,2 ,3 ]
机构
[1] Department of Materials Science and Engineering, University of California Irvine, Irvine
[2] Department of Biomedical Engineering, University of California Irvine, Irvine
[3] Department of Surgery, University of California Irvine, Irvine
来源
MRS Advances | 2020年 / 5卷 / 18-19期
关键词
Mammals - Partial pressure - Silicones;
D O I
10.1557/ADV.2020.97
中图分类号
学科分类号
摘要
Prevascularized medical devices can improve cell therapy. Such devices may replace whole organ transplantation with hosting only the necessary therapeutic cells. We have developed a noninvasive optical technology to study the vascularization into such medical devices. In our technique, oxygen partial pressure within a device is monitored by Oxygen Sensitive Tubes (OSTs), comprising oxygen permeable silicone tubing with inner luminal surfaces coated by an oxygen-sensitive porphyrin dye. OSTs were placed within a PDMS device and transplanted into the subcutaneous space of athymic nude mice. An optical probe placed over the skin excites the OSTs with a pulse of light and detects the luminescent lifetime of emitted light, which is uniquely related to oxygen partial pressure. Furthermore, we developed a Dynamic Inhalation Gas Test (DIGT) to determine the oxygen transport rate between the microvasculature and the device. DIGT works by monitoring oxygen partial pressure in a device following a step change in inhaled-gas oxygen content. We report DIGT oxygen dynamics measured intermittently over eight weeks. Our study shows DIGT dynamics are unique to each implant, supporting the important role of the host tissue response in the availability of oxygen over time. © 2020 Materials Research Society.
引用
收藏
页码:991 / 1000
页数:9
相关论文
共 50 条
  • [1] Oxygen Monitor to Study Vascularization of Medical Devices
    Najdahmadi, Avid
    Gurlin, Rachel
    Zhang, Mellonie
    Lakey, Jonathan R. T.
    Botvinick, Elliot
    MRS ADVANCES, 2020, 5 (18-19) : 991 - 1000
  • [2] Oxygen Monitor to Study Vascularization of Medical Devices
    Avid Najdahmadi
    Rachel Gurlin
    Mellonie Zhang
    Jonathan R. T. Lakey
    Elliot Botvinick
    MRS Advances, 2020, 5 : 991 - 1000
  • [3] STUDY ON TRACE OXYGEN MONITOR
    FENG, QS
    LIU, GL
    PAN, SD
    ZHAO, KB
    YU, SG
    ACTA CHIMICA SINICA, 1981, 39 (01) : 55 - 62
  • [4] SUBCONJUNCTIVAL OXYGEN IN CORNEAL VASCULARIZATION
    CHHABRA, HN
    SHARMA, DP
    EYE EAR NOSE AND THROAT MONTHLY, 1971, 50 (01): : 17 - &
  • [5] A noninvasive multimodal technique to monitor brain tumor vascularization
    Saxena, Vishal
    Gonzalez-Gomez, Ignacio
    Laug, Walter E.
    PHYSICS IN MEDICINE AND BIOLOGY, 2007, 52 (17): : 5295 - 5308
  • [6] OXYGEN MONITOR WILL STUDY CO2 IN ATMOSPHERE
    BAUM, R
    CHEMICAL & ENGINEERING NEWS, 1983, 61 (50) : 25 - 26
  • [7] Investigations about oxygen fires in electronic circuits of medical devices
    Kohl, HJ
    Morbach, A
    Degenhart, R
    FLAMMABILITY AND SENSITIVITY OF MATERIALS IN OXYGEN-ENRICHED ATMOSPHERES: NINTH VOLUME, 2000, 1395 : 57 - 69
  • [8] Validation of a novel fibreoptic sensor integrated in oxygen delivery devices as a respiratory rate monitor
    Sinha, R.
    Hernandez, F.
    Norris, A.
    ANAESTHESIA, 2019, 74 : 67 - 67
  • [9] Study on the value of medical devices in Germany
    Neubauer, G
    Lindl, C
    NEW ASPECTS OF HIGH TECHNOLOGY IN MEDICINE, 2000, : 295 - 300
  • [10] Study of Cybercrime and Security in Medical Devices
    Noimanee, S.
    Noimanee, K.
    Krisanachinda, S.
    Senavongse, W.
    2016 9TH BIOMEDICAL ENGINEERING INTERNATIONAL CONFERENCE (BMEICON), 2016,