Comprehensive performance analysis of cascade refrigeration system with two-stage compression for industrial refrigeration

被引:0
|
作者
Sun, Zhili [1 ]
Wang, Yi'An [1 ]
机构
[1] Tianjin University of Commerce, Tianjin,300134, China
关键词
Electric power utilization - Energy efficiency - Refrigerants - Refrigeration - Temperature - Thermoanalysis;
D O I
暂无
中图分类号
学科分类号
摘要
The cascade refrigeration system with two-stage compression (CRST) with R1150/R717 as the refrigerant group was studied to replace the three-stage cascade refrigeration system (TCRS) with R1150/R41/R717 as the refrigerant group, aiming to improve the operational efficiency of the industrial refrigeration system in the temperature range of -120°C to -80°C. This paper selected typical cities in five major climatic zones in China to analyze the coefficient of performance (COP), annual total power consumption, and seasonal energy efficiency ratio (SEER) of CRST and TCRS under different climatic conditions based on compressor discharge temperature, compressor input power, COP, and thermodynamic perfectibility. According to the results, the compressor input power of CRST is 1.45-1.61 kW lower than that of TCRS. CRST improved by 7.0%-11.7% in terms of COP and thermodynamic perfectibility. The seasonal performance analysis compared the CRST and TCRS operating in five different climate zones; the SEER of CRST increased by 26.3%-29.2%. CRST has a significant energy-saving effect, with an annual total power consumption of 8.6%-10.2% lower than that of TCRS. Finally, in the evaporation temperature range of -120°C to -80°C, the technical scheme of using CRST to replace TCRS in different climate zones is entirely feasible. © 2022 The Authors.
引用
收藏
相关论文
共 50 条
  • [31] Application of Integral Two-Stage Compressors in Industrial Refrigeration.
    Cosijn, E.A.
    Klima, Kalte, Heizung, 1987, 15 (7-8): : 337 - 342
  • [32] Exergy-method analysis of a two-stage vapour-compression refrigeration-plants performance
    Nikolaidis, C
    Probert, D
    APPLIED ENERGY, 1998, 60 (04) : 241 - 256
  • [33] Energy, exergy, economic and environmental analyses of a cascade absorption-compression refrigeration system using two-stage compression with complete intercooling
    Zhang, Hanyue
    Pan, Xi
    Chen, Jianye
    Xie, Junlong
    APPLIED THERMAL ENGINEERING, 2023, 225
  • [34] R744-R717 Cascade Refrigeration System: Performance Evaluation compared with a HFC Two-Stage System
    Messineo, Antonio
    2011 2ND INTERNATIONAL CONFERENCE ON ADVANCES IN ENERGY ENGINEERING (ICAEE), 2012, 14 : 56 - 65
  • [35] Experimental study on two-stage adsorption refrigeration system
    Hamamoto, Y
    Akisawa, A
    Haga, N
    Kashiwagi, T
    PROCEEDINGS OF THE INTERNATIONAL SORPTION HEAT PUMP CONFERENCE, 2002, : 550 - 555
  • [36] Optimization of Intermediate Pressure of the Two-stage Refrigeration System
    Hoang, M. T.
    Vo, C. C.
    Nguyen, T. V.
    Vu, H. K.
    PROCEEDINGS OF 2018 4TH INTERNATIONAL CONFERENCE ON GREEN TECHNOLOGY AND SUSTAINABLE DEVELOPMENT (GTSD), 2018, : 370 - 373
  • [37] Performance analysis of a two-stage ejector in an ejector refrigeration system using computational fluid dynamics
    Suvarnakuta, N.
    Pianthong, K.
    Sriveerakul, T.
    Seehanam, W.
    ENGINEERING APPLICATIONS OF COMPUTATIONAL FLUID MECHANICS, 2020, 14 (01) : 669 - 682
  • [38] Performance Analysis of an Ejector Enhanced Two-Stage Auto-Cascade Refrigeration Cycle for Low Temperature Freezer
    BAI Tao
    LU Yu
    YAN Gang
    YU Jianlin
    Journal of Thermal Science, 2021, 30 (06) : 2015 - 2026
  • [39] Performance Analysis of an Ejector Enhanced Two-Stage Auto-Cascade Refrigeration Cycle for Low Temperature Freezer
    Tao Bai
    Yu Lu
    Gang Yan
    Jianlin Yu
    Journal of Thermal Science, 2021, 30 : 2015 - 2026
  • [40] Performance Analysis of an Ejector Enhanced Two-Stage Auto-Cascade Refrigeration Cycle for Low Temperature Freezer
    Bai, Tao
    Lu, Yu
    Yan, Gang
    Yu, Jianlin
    JOURNAL OF THERMAL SCIENCE, 2021, 30 (06) : 2015 - 2026