Comprehensive performance analysis of cascade refrigeration system with two-stage compression for industrial refrigeration

被引:0
|
作者
Sun, Zhili [1 ]
Wang, Yi'An [1 ]
机构
[1] Tianjin University of Commerce, Tianjin,300134, China
关键词
Electric power utilization - Energy efficiency - Refrigerants - Refrigeration - Temperature - Thermoanalysis;
D O I
暂无
中图分类号
学科分类号
摘要
The cascade refrigeration system with two-stage compression (CRST) with R1150/R717 as the refrigerant group was studied to replace the three-stage cascade refrigeration system (TCRS) with R1150/R41/R717 as the refrigerant group, aiming to improve the operational efficiency of the industrial refrigeration system in the temperature range of -120°C to -80°C. This paper selected typical cities in five major climatic zones in China to analyze the coefficient of performance (COP), annual total power consumption, and seasonal energy efficiency ratio (SEER) of CRST and TCRS under different climatic conditions based on compressor discharge temperature, compressor input power, COP, and thermodynamic perfectibility. According to the results, the compressor input power of CRST is 1.45-1.61 kW lower than that of TCRS. CRST improved by 7.0%-11.7% in terms of COP and thermodynamic perfectibility. The seasonal performance analysis compared the CRST and TCRS operating in five different climate zones; the SEER of CRST increased by 26.3%-29.2%. CRST has a significant energy-saving effect, with an annual total power consumption of 8.6%-10.2% lower than that of TCRS. Finally, in the evaporation temperature range of -120°C to -80°C, the technical scheme of using CRST to replace TCRS in different climate zones is entirely feasible. © 2022 The Authors.
引用
收藏
相关论文
共 50 条
  • [21] Investigation on a two-stage ejection refrigeration system
    He, Yijian
    Chen, Zuozhou
    Tang, Liming
    Chen, Guangming
    APPLIED THERMAL ENGINEERING, 2015, 86 : 49 - 59
  • [22] Investigation on a two-stage ejection refrigeration system
    He, Yijian
    Chen, Zuozhou
    Tang, Liming
    Chen, Guangming
    11TH IIR GUSTAV LORENTZEN CONFERENCE ON NATURAL REFRIGERANTS (2014): NATURAL REFRIGERANTS AND ENVIRONMENTAL PROTECTION, 2014, : 799 - 806
  • [23] Hybrid Modelling of a Two-Stage Refrigeration System
    Liew, Joshua Y. L.
    Foo, Dominic C. Y.
    Putra, Zulfan Adi
    PROCESS INTEGRATION AND OPTIMIZATION FOR SUSTAINABILITY, 2024, 8 (02) : 309 - 328
  • [24] Optimization of a two-stage combined refrigeration system
    Chen, JC
    Wu, C
    ENERGY CONVERSION AND MANAGEMENT, 1996, 37 (03) : 353 - 358
  • [25] Theoretical performance comparison for two-stage auto-cascade refrigeration system using hydrocarbon refrigerants
    He, Yongning
    Wu, Huihong
    Liu, Yingying
    Wang, Tao
    Wu, Xuehong
    Cheng, Chuanxiao
    Jin, Tingxiang
    INTERNATIONAL JOURNAL OF REFRIGERATION, 2022, 142 : 27 - 36
  • [26] THERMODYNAMICAL STUDY AND TAGUCHI OPTIMIZATION OF A TWO-STAGE VAPOR COMPRESSION REFRIGERATION SYSTEM
    Kaya, Alaattin Metin
    THERMAL SCIENCE, 2022, 26 (05): : 3951 - 3963
  • [27] Second-law analysis of two-stage vapour compression refrigeration plants
    Torrella, E.
    Llopis, R.
    Cabello, R.
    Sanchez, D.
    Larumbe, J. A.
    INTERNATIONAL JOURNAL OF EXERGY, 2010, 7 (06) : 641 - 653
  • [28] Performance analysis of two-stage compression transcritical CO2 refrigeration system with 8290 mechanical subcooling unit
    Liu, Shengchun
    Lu, Fenping
    Dai, Baomin
    Nian, Victor
    Li, Hailong
    Qi, Haifeng
    Li, Jiayu
    ENERGY, 2019, 189
  • [29] Exergy analysis of vapour compression-absorption two-stage refrigeration cycle
    Ozturk, Ilhan Tekin
    Cimsit, Canan
    INTERNATIONAL JOURNAL OF EXERGY, 2021, 35 (02) : 210 - 221
  • [30] Performance analysis of a dual-ejector enhanced two-stage auto-cascade refrigeration cycle for ultra-low temperature refrigeration
    Shi, Rongxuan
    Bai, Tao
    Wan, Jiahao
    APPLIED THERMAL ENGINEERING, 2024, 240