Development and validation of 3D printed anthropomorphic head phantom with eccentric holes for medical LINAC quality assurance testing in stereotactic radiosurgery

被引:0
|
作者
Nabhan, A. K. Shahi [1 ]
Saxena, Kritik [1 ]
Puzhakkal, Niyas [2 ]
Mathew, Jose [1 ]
Lawrence, K. Deepak [1 ]
机构
[1] Natl Inst Technol, Dept Mech Engn, Calicut, India
[2] MVR Canc Ctr & Res Inst, Dept Radiat Oncol, Calicut, India
关键词
Stereotactic radiosurgery; Linear accelerator; Anthropomorphic phantom; 3D printing; Treatment planning system; Patient specific quality assurance; WATER EQUIVALENCE; DOSIMETER;
D O I
10.1016/j.medengphy.2024.104217
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Stereotactic Radiosurgery (SRS) for brain tumors using Medical Linear Accelerator (LINAC) demands high precision and accuracy. A specific Quality Assurance (QA) is essential for every patient undergoing SRS to protect nearby non-cancerous cells by ensuring that the X-ray beams are targeted according to tumor position. In this work, a water-filled generic anthropomorphic head phantom consisting of two removable parts with eccentric holes was developed using Additive Manufacturing (AM) process for performing QA in SRS. In the patient specific QA, the planned radiation dose using Treatment Planning System (TPS) was compared with the dose measured in the phantom. Also, the energy consistency of radiation beams was tested at 200 MU for different energy beams at the central and eccentric holes of the phantom using an ionization chamber. Experimentally examined results show that planned doses in TPS are reaching the target within a 5% deviation. The ratio of the dose delivered in the eccentric hole to the dose delivered to the central hole shows variations of less than 2% for the energy consistency test. The designed, low-cost water-filled anthropomorphic phantom is observed to improve positioning verification and accurate dosimetry of patient-specific QA in SRS treatment.
引用
收藏
页数:11
相关论文
共 46 条
  • [1] Development of a 3D printed phantom for commissioning and quality assurance of multiple brain targets stereotactic radiosurgery
    Mukwada, Godfrey
    Hirst, Andrew
    Rowshanfarzad, Pejman
    Ebert, Martin A.
    PHYSICAL AND ENGINEERING SCIENCES IN MEDICINE, 2024, 47 (02) : 455 - 463
  • [2] Design, Development, and Evaluation of a Modified, Anthropomorphic, Head, Quality Assurance Phantom for Use in Stereotactic Radiosurgery
    Faught, A.
    Kry, S.
    Luo, D.
    Molineu, A.
    Bellezza, D.
    Gerber, R.
    Davidson, S.
    Bosch, W.
    Galvin, J.
    Drzymala, R.
    Timmerman, R.
    Sheehan, J.
    Gillin, M.
    Ibbott, G.
    Followill, D.
    MEDICAL PHYSICS, 2012, 39 (06) : 3746 - 3747
  • [3] Design, Development, and Evaluation of a Modified, Anthropomorphic, Head and Neck, Quality Assurance Phantom for Use in Stereotactic Radiosurgery
    Faught, A.
    Kry, S.
    Luo, D.
    Molineu, A.
    Galvin, J.
    Drzymala, R.
    Timmerman, R.
    Sheehan, J.
    Gillin, M.
    Ibbott, G.
    Followill, D.
    MEDICAL PHYSICS, 2011, 38 (06)
  • [4] Characterization of a novel 3D printed patient specific phantom for quality assurance in cranial stereotactic radiosurgery applications
    Makris, D. N.
    Pappas, E. P.
    Zoros, E.
    Papanikolaou, N.
    Saenz, D. L.
    Kalaitzakis, G.
    Zourari, K.
    Efstathopoulos, E.
    Maris, T. G.
    Pappas, E.
    PHYSICS IN MEDICINE AND BIOLOGY, 2019, 64 (10):
  • [5] Use of a micro-ionization chamber and an anthropomorphic head phantom in a quality assurance program for stereotactic radiosurgery
    Duggan, DM
    Coffey, CW
    MEDICAL PHYSICS, 1996, 23 (04) : 513 - 516
  • [6] An anthropomorphic 3D printed inhomogeneity thorax phantom slab for SBRT commissioning and quality assurance
    Stephen How
    Dilli Banjade
    Scott Crowe
    Greg Dillon
    Andrew Skimmings
    Physical and Engineering Sciences in Medicine, 2023, 46 : 575 - 583
  • [7] An anthropomorphic 3D printed inhomogeneity thorax phantom slab for SBRT commissioning and quality assurance
    How, Stephen
    Banjade, Dilli
    Crowe, Scott
    Dillon, Greg
    Skimmings, Andrew
    PHYSICAL AND ENGINEERING SCIENCES IN MEDICINE, 2023, 46 (02) : 575 - 583
  • [8] Development of a modified head and neck quality assurance phantom for use in stereotactic radiosurgery trials
    Faught, Austin M.
    Kry, Stephen F.
    Luo, Dershan
    Molineu, Andrea
    Bellezza, David
    Gerber, Russell L.
    Davidson, Scott E.
    Bosch, Walter
    Drzymala, Robert E.
    Galvin, Jim
    Timmerman, Robert
    Sheehan, Jason
    Gillin, Michael T.
    Ibbott, Geoffrey S.
    Followill, David S.
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2013, 14 (04): : 206 - 215
  • [9] Development of a 3D printed anthropomorphic lung phantom for image quality assessment in CT
    Hernandez-Giron, Irene
    den Harder, Johan Michiel
    Streekstra, Geert J.
    Geleijns, Jacob
    Veldkamp, Wouter J. H.
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2019, 57 : 47 - 57
  • [10] Development of Novel Heterogeneous Anthropomorphic Head and Neck Phantom Using 3D Printer for IMRT Patient Specific Quality Assurance
    Kadoya, N.
    Abe, K.
    Nemoto, H.
    Sato, K.
    Ieko, Y.
    Ito, K.
    Takayama, Y.
    Chiba, T.
    Dobashi, S.
    Takeda, K.
    Jingu, K.
    MEDICAL PHYSICS, 2018, 45 (06) : E595 - E595