An anthropomorphic 3D printed inhomogeneity thorax phantom slab for SBRT commissioning and quality assurance

被引:1
|
作者
How, Stephen [1 ]
Banjade, Dilli [1 ]
Crowe, Scott [2 ]
Dillon, Greg [1 ]
Skimmings, Andrew [3 ]
机构
[1] Cent West Canc Care Ctr, 1503 Forest Rd, Orange, NSW 2800, Australia
[2] Royal Brisbane & Womens Hosp, Butterfield St, Herston, Qld 4029, Australia
[3] North West Canc Ctr, Dean St, North Tamworth, NSW 2340, Australia
关键词
3D printing; Inhomogeneity; Phantom; SBRT; Commissioning; Quality assurance;
D O I
10.1007/s13246-023-01233-8
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Anthropomorphic phantoms with tissue equivalency are required in radiotherapy for quality assurance of imaging and dosimetric processes used in radiotherapy treatments. Commercial phantoms are expensive and provide limited approximation to patient geometry and tissue equivalency. In this study, a 5 cm thick anthropomorphic thoracic slab phantom was designed and 3D printed using models exported from a CT dataset to demonstrate the feasibility of manufacturing anthropomorphic 3D printed phantoms onsite in a clinical radiotherapy department. The 3D printed phantom was manufactured with polylactic acid with an in-fill density of 80% to simulate tissue density and 26% to simulate lung density. A common radio-opacifier, barium sulfate (BaSO4), was added 6% w/w to an epoxy resin mixture to simulate similar HU numbers for bone equivalency. A half-cylindrical shape was cropped away from the spine region to allow insertion of the bone equivalent mixture. Two Gafchromic (TM) EBT3 film strips were inserted into the 3D printed phantom to measure the delivery of two stereotactic radiotherapy plans targeting lung and bone lesions respectively. Results were analysed within SNC Patient with a low dose threshold of 10% and a gamma criterion of 3%/2 mm and 5%/1 mm. The resulting gamma pass rate across both criterions for lung and bone were >= 95% and approximately 85% respectively. Results shows that a cost-effective anthropomorphic 3D printed phantom with realistic heterogeneity simulation can be fabricated in departments with access a suitable 3D printer, which can be used for performing commissioning and quality assurance for stereotactic type radiotherapy to lesions in the presence of heterogeneity.
引用
收藏
页码:575 / 583
页数:9
相关论文
共 50 条
  • [1] An anthropomorphic 3D printed inhomogeneity thorax phantom slab for SBRT commissioning and quality assurance
    Stephen How
    Dilli Banjade
    Scott Crowe
    Greg Dillon
    Andrew Skimmings
    Physical and Engineering Sciences in Medicine, 2023, 46 : 575 - 583
  • [2] Robotic 3D Printed Quality Assurance Phantom for Commissioning Lung Calypso
    Capaldi, D.
    Zhang, H.
    Skinner, L.
    Dubrowski, P.
    Bush, K.
    Xing, L.
    Fahimian, B.
    Yu, A.
    MEDICAL PHYSICS, 2020, 47 (06) : E846 - E846
  • [3] 3D printed inhomogeneity phantom for radiotherapy commissioning and QA measurements
    Banjade, D.
    How, S.
    RADIOTHERAPY AND ONCOLOGY, 2023, 182 : S1514 - S1514
  • [4] Development of a 3D printed phantom for commissioning and quality assurance of multiple brain targets stereotactic radiosurgery
    Mukwada, Godfrey
    Hirst, Andrew
    Rowshanfarzad, Pejman
    Ebert, Martin A.
    PHYSICAL AND ENGINEERING SCIENCES IN MEDICINE, 2024, 47 (02) : 455 - 463
  • [5] Using 3D Printing to Manufacture An Anthropomorphic Thorax Phantom
    Hazelaar, C.
    Dahele, M.
    van Eijnatten, M.
    Wolff, J.
    Forouzanfar, T.
    Slotman, B.
    Verbakel, W.
    MEDICAL PHYSICS, 2017, 44 (06) : 3113 - 3113
  • [6] A Novel 3D Printed Patient-Specific Phantom for Spine SBRT Quality Assurance: Comparison of 3D Printing Techniques
    Lee, S.
    Kim, M.
    Lee, M.
    Suh, T.
    MEDICAL PHYSICS, 2016, 43 (06) : 3631 - 3631
  • [7] Dynamic anthropomorphic thorax phantom for quality assurance of motion management in radiotherapy
    Abdollahi, Sara
    Mowlavi, Ali Asghar
    Yazdi, Mohammad Hadi Hadizadeh
    Ceberg, Sofie
    Aznar, Marianne Camille
    Tabrizi, Fatemeh Varshoee
    Salek, Roham
    Guckenberger, Matthias
    Tanadini-Lang, Stephanie
    PHYSICS & IMAGING IN RADIATION ONCOLOGY, 2024, 30
  • [8] Patient specific 3D printed phantom for IMRT quality assurance
    Ehler, Eric D.
    Barney, Brett M.
    Higgins, Patrick D.
    Dusenbery, Kathryn E.
    PHYSICS IN MEDICINE AND BIOLOGY, 2014, 59 (19): : 5763 - 5773
  • [9] Development of a 3D printed anthropomorphic lung phantom for image quality assessment in CT
    Hernandez-Giron, Irene
    den Harder, Johan Michiel
    Streekstra, Geert J.
    Geleijns, Jacob
    Veldkamp, Wouter J. H.
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2019, 57 : 47 - 57
  • [10] A 3D Printed Phantom for the Use of Daily Quality Assurance Alignment Tests
    Woods, K.
    Ayan, A.
    Woollard, J.
    Gardner, N.
    Gupta, N.
    MEDICAL PHYSICS, 2016, 43 (06) : 3418 - 3418