Development and Validation of a Mobile Phone Application for Measuring Knee Range of Motion

被引:0
|
作者
Gong, Matthew F. [1 ]
Finger, Logan E. [1 ]
Letter, Christina [2 ]
Amirian, Soheyla [3 ]
Parmanto, Bambang [2 ]
O'Malley, Michael [1 ]
Klatt, Brian A. [1 ]
Tafti, Ahmad P. [2 ]
Plate, Johannes F. [1 ]
机构
[1] Univ Pittsburgh, Med Ctr, Dept Orthopaed Surg, Pittsburgh, PA USA
[2] Univ Pittsburgh, Sch Hlth & Rehabil Sci, Dept Hlth Informat Management, Pittsburgh, PA USA
[3] Pace Univ, Seidenberg Sch Comp Sci & Informat Syst, New York, NY USA
关键词
orthopaedic surgery; adult reconstruction; postoperative rehabilitation; technology; knee arthroplasty; STIFFNESS; JOINTS; HIP;
D O I
10.1055/a-2388-0812
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Knee range of motion (ROM) is an important indicator of knee function. Outside the clinical setting, patients may not be able to accurately assess knee ROM, which may impair recovery following trauma or surgery. This study aims to validate a smartphone mobile application developed to measure knee ROM compared to visual and goniometer ROM measurements. A knee ROM Android mobile application was developed to measure knee ROM. Patients > 18 years old presenting to an orthopaedic clinic with native knee complaints were approached to participate. Knee ROM was measured bilaterally by an arthroplasty-trained surgeon using (1) vision, (2) goniometer, and (3) the mobile application. Measurements were compared in flexion and extension using a one-way analysis of variance with post hoc Tukey test (alpha = 0.05). Eighty-four knee ROM measurements (40 left, 44 right) were obtained in 47 patients. Median Kellgren- Lawrence grade from available radiographs was grade 3. In flexion, mobile application (117.6 + 14.7 degrees) measurements were not significantly different from visual (116.1 + 13.6 degrees) or goniometer (116.2 + 13.6 degrees) measurements. In extension, mobile application (4.8 + 7.3 degrees) measurements were significantly different from visual (1.9+ 4.1 degrees) measurements on post hoc analysis (p < 0.01), while no differences were present compared to goniometer (3.1 +5.8 degrees) measurements. Our study found that a mobile application for evaluating knee ROM was noninferior to goniometer-based measurements performed by an arthroplasty-trained surgeon. Future studies will investigate this application's utility in (1) remote patient care, (2) accelerating recovery during rehabilitation, (3) detecting early postoperative complications including arthrofibrosis, and (4) adding additional functionalities to the application to provide more detail-oriented descriptive analyses of patient knee function.
引用
收藏
页码:22 / 27
页数:6
相关论文
共 50 条
  • [41] Validation of a Spanish Questionnaire on Mobile Phone Abuse
    Olivencia-Carrion, Mara A.
    Ramirez-Ucles, Isabel
    Holgado-Tello, Pablo
    Lopez-Torrecillas, Francisca
    FRONTIERS IN PSYCHOLOGY, 2018, 9
  • [42] Mobile Motion Gaming: Mobile Motion Gaming: Enabling a New Class of Phone-to-Phone Action Games on Commodity Phones
    Zhang, Zengbin
    Chu, David
    Chen, Xiaomeng
    Moscibroda, Thomas
    IEEE TRANSACTIONS ON MOBILE COMPUTING, 2013, 12 (08) : 1487 - 1501
  • [43] VALIDATION OF MOBILE APPLICATION MEASURING VOIDED VOLUME: A PILOT PROSPECTIVE STUDY
    Kim, Hwanik
    Kim, Jin Hyuck
    Ye, Changhee
    Jung, Gyoohwan
    Kim, Jung Kwon
    Lee, Hakmin
    Jeong, Seong Jin
    Lee, Sangchul
    JOURNAL OF UROLOGY, 2022, 207 (05): : E482 - E483
  • [44] Development and Validation of a Motion and Loading System for a Rat Knee Joint In Vivo
    Xiang Ian Gu
    Daniel J. Leong
    Francisco Guzman
    Rashal Mahamud
    Yong Hui Li
    Robert J. Majeska
    Mitchell B. Schaffler
    Hui Bin Sun
    Luis Cardoso
    Annals of Biomedical Engineering, 2010, 38 : 621 - 631
  • [45] Development and Validation of a Motion and Loading System for a Rat Knee Joint In Vivo
    Gu, Xiang Ian
    Leong, Daniel J.
    Guzman, Francisco
    Mahamud, Rashal
    Li, Yong Hui
    Majeska, Robert J.
    Schaffler, Mitchell B.
    Sun, Hui Bin
    Cardoso, Luis
    ANNALS OF BIOMEDICAL ENGINEERING, 2010, 38 (03) : 621 - 631
  • [46] Development of motion detection algorithms based on simultaneous processing using mobile phone sensors
    Zsofia, Sandor
    Kis, Gergely
    INFORMACIOS TARSADALOM, 2016, 16 (01): : 57 - +
  • [47] Development of a mobile application for prenatal care and content validation
    Costa Souza, Francisca Marta de Lima
    dos Santos, Wenysson Delete
    Dante, Janmilli da Costa
    Alves de Sousa, Helena Rangel
    Alencar Moreirai, Olga Alice
    Rosendo da Silva, Richardson Augusta
    ACTA PAULISTA DE ENFERMAGEM, 2022, 35
  • [48] Development of a Mobile Phone addiction craving scale and its Validation in a spanish adult Population
    De-Sola, Jose
    Talledo, Hernan
    Rubio, Gabriel
    Rodriguez de Fonseca, Fernando
    FRONTIERS IN PSYCHIATRY, 2017, 8
  • [49] Development of an Automatic Instrument for Efficient Measuring the Joint's Range of Motion
    Jo, Yeeun
    Kim, Myungjoon
    Kim, Yoon Jae
    Lee, Chiwon
    Park, Eun Hye
    Park, Jun Won
    Lee, Eunbong
    Kim, Sungwan
    INTERNATIONAL JOURNAL OF CONTROL AUTOMATION AND SYSTEMS, 2019, 17 (11) : 2722 - 2733
  • [50] Development of an Automatic Instrument for Efficient Measuring the Joint’s Range of Motion
    Yeeun Jo
    Myungjoon Kim
    Yoon Jae Kim
    Chiwon Lee
    Eun Hye Park
    Jun Won Park
    Eunbong Lee
    Sungwan Kim
    International Journal of Control, Automation and Systems, 2019, 17 : 2722 - 2733