Development and Validation of a Mobile Phone Application for Measuring Knee Range of Motion

被引:0
|
作者
Gong, Matthew F. [1 ]
Finger, Logan E. [1 ]
Letter, Christina [2 ]
Amirian, Soheyla [3 ]
Parmanto, Bambang [2 ]
O'Malley, Michael [1 ]
Klatt, Brian A. [1 ]
Tafti, Ahmad P. [2 ]
Plate, Johannes F. [1 ]
机构
[1] Univ Pittsburgh, Med Ctr, Dept Orthopaed Surg, Pittsburgh, PA USA
[2] Univ Pittsburgh, Sch Hlth & Rehabil Sci, Dept Hlth Informat Management, Pittsburgh, PA USA
[3] Pace Univ, Seidenberg Sch Comp Sci & Informat Syst, New York, NY USA
关键词
orthopaedic surgery; adult reconstruction; postoperative rehabilitation; technology; knee arthroplasty; STIFFNESS; JOINTS; HIP;
D O I
10.1055/a-2388-0812
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Knee range of motion (ROM) is an important indicator of knee function. Outside the clinical setting, patients may not be able to accurately assess knee ROM, which may impair recovery following trauma or surgery. This study aims to validate a smartphone mobile application developed to measure knee ROM compared to visual and goniometer ROM measurements. A knee ROM Android mobile application was developed to measure knee ROM. Patients > 18 years old presenting to an orthopaedic clinic with native knee complaints were approached to participate. Knee ROM was measured bilaterally by an arthroplasty-trained surgeon using (1) vision, (2) goniometer, and (3) the mobile application. Measurements were compared in flexion and extension using a one-way analysis of variance with post hoc Tukey test (alpha = 0.05). Eighty-four knee ROM measurements (40 left, 44 right) were obtained in 47 patients. Median Kellgren- Lawrence grade from available radiographs was grade 3. In flexion, mobile application (117.6 + 14.7 degrees) measurements were not significantly different from visual (116.1 + 13.6 degrees) or goniometer (116.2 + 13.6 degrees) measurements. In extension, mobile application (4.8 + 7.3 degrees) measurements were significantly different from visual (1.9+ 4.1 degrees) measurements on post hoc analysis (p < 0.01), while no differences were present compared to goniometer (3.1 +5.8 degrees) measurements. Our study found that a mobile application for evaluating knee ROM was noninferior to goniometer-based measurements performed by an arthroplasty-trained surgeon. Future studies will investigate this application's utility in (1) remote patient care, (2) accelerating recovery during rehabilitation, (3) detecting early postoperative complications including arthrofibrosis, and (4) adding additional functionalities to the application to provide more detail-oriented descriptive analyses of patient knee function.
引用
收藏
页码:22 / 27
页数:6
相关论文
共 50 条
  • [11] Research and development of application of mobile barcode to mobile sightseeing guide on mobile phone
    Cheh, Ming Chin
    Weng, Tingsheng
    WSEAS Transactions on Information Science and Applications, 2010, 7 (01): : 16 - 25
  • [12] Knee Osteoarthritis Patients Can Provide Useful Estimates of Passive Knee Range of Motion: Development and Validation of the Copenhagen Knee ROM Scale
    Morup-Petersen, Anne
    Holm, Paetur M.
    Holm, Christina E.
    Klausen, Tobias W.
    Skou, Soren T.
    Krogsgaard, Michael R.
    Laursen, Mogens B.
    Odgaard, Anders
    JOURNAL OF ARTHROPLASTY, 2018, 33 (09): : 2875 - +
  • [13] Reliability and Validity of a Digital Goniometer for Measuring Knee Joint Range of Motion
    Lind, Veronika
    Svensson, Melanie
    Harringe, Marita L.
    MEASUREMENT IN PHYSICAL EDUCATION AND EXERCISE SCIENCE, 2022, 26 (03) : 191 - 198
  • [14] Development of a Mobile Phone App for Measuring Striking Response Time in Combat Sports: Cross-Sectional Validation Study
    Coswig, Victor
    Ana, Jader Sant'
    Coelho, Maicon Nascimento
    Pereira Moro, Antonio Renato
    Diefenthaeler, Fernando
    JMIR MHEALTH AND UHEALTH, 2019, 7 (11):
  • [15] Measuring mobile learning readiness: scale development and validation
    Lin, Hsin-Hui
    Lin, Shinjeng
    Yeh, Ching-Hsuan
    Wang, Yi-Shun
    INTERNET RESEARCH, 2016, 26 (01) : 265 - 287
  • [16] Measuring Integrity on Mobile Phone Systems
    Muthukumaran, Divya
    Sawani, Anuj
    Jung, Brian M.
    Jaeger, Trent
    Schiffman, Joshua
    SACMAT'08: PROCEEDINGS OF THE 13TH ACM SYMPOSIUM ON ACCESS CONTROL MODELS AND TECHNOLOGIES, 2008, : 155 - 164
  • [17] Evaluating Network Readiness for mHealth Interventions Using the Beacon Mobile Phone App: Application Development and Validation Study
    Scherr, Thomas Foster
    Moore, Carson Paige
    Thuma, Philip
    Wright, David Wilson
    JMIR MHEALTH AND UHEALTH, 2020, 8 (07):
  • [18] Application development with J2ME for mobile phone
    Faculty of Electronic Engineering and Computer Engineering, Universiti Teknikal Malaysia Melaka, Malaysia
    不详
    Int. Conf. Adv. Commun. Technol. ICACT, (1420-1423):
  • [19] MEASURING RANGE OF MOTION
    SCHENKER, AW
    KNAPP, ME
    POSTGRADUATE MEDICINE, 1968, 43 (06) : 60 - &
  • [20] MEASURING RANGE OF MOTION
    KNAPP, ME
    POSTGRADUATE MEDICINE, 1967, 42 (04) : A123 - &