Validation of a Novel Method for Noninvasive Mixed Venous Oxygen Saturation Monitoring in Anesthetized Children

被引:1
|
作者
Svedmyr, Anders [1 ,2 ]
Steiner, Kristoffer [3 ,4 ]
Andersson, Andreas [1 ,2 ]
Sjoberg, Gunnar [3 ,4 ]
Hallback, Magnus [5 ]
Wallin, Mats [1 ]
Lonnqvist, Per-Arne [1 ,2 ]
Karlsson, Jacob [1 ,2 ]
机构
[1] Karolinska Inst, Dept Physiol & Pharmacol FYFA, Sect Anesthesiol & Intens Care, Pearne Lonnqvist Grp,C3,Eriksson I Lars, Stockholm, Sweden
[2] Karolinska Univ Hosp, Dept Pediat Perioperat Med & Intens Care, Stockholm, Sweden
[3] Karolinska Univ Hosp, Dept Pediat Cardiol, Stockholm, Sweden
[4] Karolinska Inst, Dept Womens & Childrens Hlth, Stockholm, Sweden
[5] Maquet Crit Care AB, Solna, Sweden
来源
ANESTHESIA AND ANALGESIA | 2024年 / 139卷 / 04期
关键词
CONTINUOUS CAPNODYNAMIC METHOD; CARDIAC-OUTPUT ASSESSMENT; AGREEMENT;
D O I
10.1213/ANE.0000000000007083
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
BACKGROUND:Mixed venous oxygen saturation (SvO2) is a critical variable in the assessment of oxygen supply and demand but is rarely used in children due to the invasive nature of pulmonary artery catheters. The aim of this prospective, observational study was to investigate the accuracy of noninvasively measured SvO2 acquired by the novel capnodynamic method, based on differential Fick equation (Capno-SvO2), against gold standard CO-oximetry.METHODS:Capno-SvO2 was compared to SvO2 measured by pulmonary artery blood gas CO-oximetry in children undergoing cardiac catheter interventions and subjected to moderate hemodynamic challenges. Bland-Altman analysis was used to describe the agreement of absolute values between CO-oximetry and Capno-SvO2, and a concordance rate was calculated to evaluate the ability of Capno-SvO2 to track change.RESULTS:Twenty-five procedures were included in the study. Capno-SvO2 showed a bias toward CO-oximetry of +3 percentage points; upper and lower limits of agreement were +11 percentage points (95% confidence interval [CI], 9-14) and -5 percentage points (95% CI, -8 to -3), respectively. The concordance rate was 92% (95% CI, 89-96).CONCLUSIONS:In conclusion, this first clinical application of a novel concept for noninvasive SvO2 monitoring without the need for a pulmonary artery catheter indicates that Capno-SvO2 generates absolute values and trending capacity in close agreement with the gold standard reference method.
引用
收藏
页码:781 / 788
页数:8
相关论文
共 50 条
  • [31] CONTINUOUS MONITORING OF MIXED VENOUS OXYGEN-SATURATION IN CLINICAL-PRACTICE
    MCMICHAN, JC
    MOUNT SINAI JOURNAL OF MEDICINE, 1984, 51 (05): : 569 - 572
  • [32] OXIMETRIC METHOD FOR DETERMINATION OF THE OXYGEN SATURATION OF MIXED VENOUS BLOOD IN MAN
    KNUTSON, J
    TAYLOR, BE
    WOOD, EH
    FEDERATION PROCEEDINGS, 1949, 8 (01) : 87 - 87
  • [33] ONLINE MONITORING OF MIXED VENOUS OXYGEN-SATURATION AFTER CARDIOTHORACIC SURGERY
    KRAUSS, XH
    VERDOUW, PD
    HUGENHOLTZ, PG
    NAUTA, J
    THORAX, 1975, 30 (06) : 636 - 643
  • [34] CONTINUOUS MONITORING OF MIXED VENOUS OXYGEN-SATURATION IN CRITICALLY ILL PATIENTS
    BAELE, PL
    MCMICHAN, JC
    MARSH, HM
    SILL, JC
    SOUTHORN, PA
    ANESTHESIA AND ANALGESIA, 1982, 61 (06): : 513 - 517
  • [35] Comparison of central venous oxygen saturation and mixed venous oxygen saturation during liver transplantation
    El Masry, A.
    Mukhtar, A. M.
    El Sherbeny, A. M.
    Fathy, M.
    El-Meteini, M.
    ANAESTHESIA, 2009, 64 (04) : 378 - 382
  • [36] CONTINUOUS MONITORING OF MIXED VENOUS-BLOOD OXYGEN-SATURATION - REPLY
    BOUTROS, A
    CRITICAL CARE MEDICINE, 1987, 15 (01) : 87 - 87
  • [37] MIXED VENOUS OXYGEN-SATURATION MONITORING DURING LIVER-TRANSPLANTATION
    STEIB, A
    GOHARD, R
    BELLER, JP
    FREYS, G
    LLEU, JC
    OTTENI, JC
    EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 1993, 10 (04) : 267 - 271
  • [38] Mixed venous oxygen saturation cannot be estimated by central venous oxygen saturation in septic shock
    Marjut Varpula
    Sari Karlsson
    Esko Ruokonen
    Ville Pettilä
    Intensive Care Medicine, 2006, 32 : 1336 - 1343
  • [39] Monitoring of venous oxygen saturation using a novel vibratory oximetry sensor
    Shaltis, P
    Asada, H
    SECOND JOINT EMBS-BMES CONFERENCE 2002, VOLS 1-3, CONFERENCE PROCEEDINGS: BIOENGINEERING - INTEGRATIVE METHODOLOGIES, NEW TECHNOLOGIES, 2002, : 1722 - 1723
  • [40] CONTINUOUS MONITORING OF MIXED VENOUS OXYGEN-SATURATION IN CARDIAC-SURGERY
    JAMIESON, WRE
    TURNBULL, KW
    LARRIEU, AJ
    DODDS, WA
    ALLISON, JC
    TYERS, GFO