Validation of a Novel Method for Noninvasive Mixed Venous Oxygen Saturation Monitoring in Anesthetized Children

被引:1
|
作者
Svedmyr, Anders [1 ,2 ]
Steiner, Kristoffer [3 ,4 ]
Andersson, Andreas [1 ,2 ]
Sjoberg, Gunnar [3 ,4 ]
Hallback, Magnus [5 ]
Wallin, Mats [1 ]
Lonnqvist, Per-Arne [1 ,2 ]
Karlsson, Jacob [1 ,2 ]
机构
[1] Karolinska Inst, Dept Physiol & Pharmacol FYFA, Sect Anesthesiol & Intens Care, Pearne Lonnqvist Grp,C3,Eriksson I Lars, Stockholm, Sweden
[2] Karolinska Univ Hosp, Dept Pediat Perioperat Med & Intens Care, Stockholm, Sweden
[3] Karolinska Univ Hosp, Dept Pediat Cardiol, Stockholm, Sweden
[4] Karolinska Inst, Dept Womens & Childrens Hlth, Stockholm, Sweden
[5] Maquet Crit Care AB, Solna, Sweden
来源
ANESTHESIA AND ANALGESIA | 2024年 / 139卷 / 04期
关键词
CONTINUOUS CAPNODYNAMIC METHOD; CARDIAC-OUTPUT ASSESSMENT; AGREEMENT;
D O I
10.1213/ANE.0000000000007083
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
BACKGROUND:Mixed venous oxygen saturation (SvO2) is a critical variable in the assessment of oxygen supply and demand but is rarely used in children due to the invasive nature of pulmonary artery catheters. The aim of this prospective, observational study was to investigate the accuracy of noninvasively measured SvO2 acquired by the novel capnodynamic method, based on differential Fick equation (Capno-SvO2), against gold standard CO-oximetry.METHODS:Capno-SvO2 was compared to SvO2 measured by pulmonary artery blood gas CO-oximetry in children undergoing cardiac catheter interventions and subjected to moderate hemodynamic challenges. Bland-Altman analysis was used to describe the agreement of absolute values between CO-oximetry and Capno-SvO2, and a concordance rate was calculated to evaluate the ability of Capno-SvO2 to track change.RESULTS:Twenty-five procedures were included in the study. Capno-SvO2 showed a bias toward CO-oximetry of +3 percentage points; upper and lower limits of agreement were +11 percentage points (95% confidence interval [CI], 9-14) and -5 percentage points (95% CI, -8 to -3), respectively. The concordance rate was 92% (95% CI, 89-96).CONCLUSIONS:In conclusion, this first clinical application of a novel concept for noninvasive SvO2 monitoring without the need for a pulmonary artery catheter indicates that Capno-SvO2 generates absolute values and trending capacity in close agreement with the gold standard reference method.
引用
收藏
页码:781 / 788
页数:8
相关论文
共 50 条
  • [21] Oxygen delivery and venous oxygen saturation monitoring
    Singh, S
    HOSPITAL MEDICINE, 2003, 64 (02): : 125 - 125
  • [22] MIXED VENOUS OXYGEN-SATURATION
    PIANTADOSI, S
    BRADLEY, EL
    ANNALS OF EMERGENCY MEDICINE, 1981, 10 (10) : 548 - 548
  • [23] MIXED VENOUS OXYGEN-SATURATION
    HANNEMANN, L
    REINHART, K
    ACTA MEDICA AUSTRIACA, 1993, 20 (04) : 107 - 111
  • [24] MIXED VENOUS OXYGEN-SATURATION
    REINHART, K
    SCHAFER, M
    RUDOLPH, T
    SPECHT, M
    ACP-APPLIED CARDIOPULMONARY PATHOPHYSIOLOGY, 1988, 2 (04): : 315 - 325
  • [25] Monitoring cerebral oxygen saturation using near infrared spectroscopy during cardiopulmonary bypass: Comparing with monitoring mixed venous oxygen saturation
    Teng Yichao
    Ding Haishu
    Huang Lan
    Gong Qingcheng
    2007 IEEE/ICME INTERNATIONAL CONFERENCE ON COMPLEX MEDICAL ENGINEERING, VOLS 1-4, 2007, : 1008 - +
  • [26] NONINVASIVE METHODS OF MEASURING OXYGEN SATURATION IN VENOUS BLOOD
    Yesman, S. S.
    Mamilov, S. A.
    Asimov, M. M.
    Gisbreht, A. I.
    JOURNAL OF APPLIED SPECTROSCOPY, 2011, 78 (03) : 406 - 413
  • [27] Noninvasive methods of measuring oxygen saturation in venous blood
    S. S. Yesman
    S. A. Mamilov
    M. M. Asimov
    A. I. Gisbreht
    Journal of Applied Spectroscopy, 2011, 78 : 406 - 413
  • [28] CONTINUOUS MONITORING OF MIXED VENOUS OXYGEN-SATURATION DURING CORONARY ANGIOPLASTY
    CARRIE, D
    BOUDJEMAA, B
    DERBEL, F
    FERRIERES, J
    DELAY, M
    BERNADET, P
    ARCHIVES DES MALADIES DU COEUR ET DES VAISSEAUX, 1993, 86 (10): : 1439 - 1444
  • [29] THE PHYSIOLOGICAL-BASIS FOR CONTINUOUS MIXED VENOUS OXYGEN-SATURATION MONITORING
    WHITE, KM
    WINSLOW, EH
    CLARK, AP
    TYLER, DO
    HEART & LUNG, 1990, 19 (05): : 548 - 551
  • [30] CONTINUOUS MONITORING OF MIXED VENOUS OXYGEN-SATURATION AS AN INDICATOR OF PHARMACOLOGIC INTERVENTION
    HASSAN, E
    GREEN, JA
    NARA, AR
    JARVIS, RC
    KASMER, RJ
    POSPISIL, R
    CHEST, 1989, 95 (02) : 406 - 409