Validation of a Novel Method for Noninvasive Mixed Venous Oxygen Saturation Monitoring in Anesthetized Children

被引:1
|
作者
Svedmyr, Anders [1 ,2 ]
Steiner, Kristoffer [3 ,4 ]
Andersson, Andreas [1 ,2 ]
Sjoberg, Gunnar [3 ,4 ]
Hallback, Magnus [5 ]
Wallin, Mats [1 ]
Lonnqvist, Per-Arne [1 ,2 ]
Karlsson, Jacob [1 ,2 ]
机构
[1] Karolinska Inst, Dept Physiol & Pharmacol FYFA, Sect Anesthesiol & Intens Care, Pearne Lonnqvist Grp,C3,Eriksson I Lars, Stockholm, Sweden
[2] Karolinska Univ Hosp, Dept Pediat Perioperat Med & Intens Care, Stockholm, Sweden
[3] Karolinska Univ Hosp, Dept Pediat Cardiol, Stockholm, Sweden
[4] Karolinska Inst, Dept Womens & Childrens Hlth, Stockholm, Sweden
[5] Maquet Crit Care AB, Solna, Sweden
来源
ANESTHESIA AND ANALGESIA | 2024年 / 139卷 / 04期
关键词
CONTINUOUS CAPNODYNAMIC METHOD; CARDIAC-OUTPUT ASSESSMENT; AGREEMENT;
D O I
10.1213/ANE.0000000000007083
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
BACKGROUND:Mixed venous oxygen saturation (SvO2) is a critical variable in the assessment of oxygen supply and demand but is rarely used in children due to the invasive nature of pulmonary artery catheters. The aim of this prospective, observational study was to investigate the accuracy of noninvasively measured SvO2 acquired by the novel capnodynamic method, based on differential Fick equation (Capno-SvO2), against gold standard CO-oximetry.METHODS:Capno-SvO2 was compared to SvO2 measured by pulmonary artery blood gas CO-oximetry in children undergoing cardiac catheter interventions and subjected to moderate hemodynamic challenges. Bland-Altman analysis was used to describe the agreement of absolute values between CO-oximetry and Capno-SvO2, and a concordance rate was calculated to evaluate the ability of Capno-SvO2 to track change.RESULTS:Twenty-five procedures were included in the study. Capno-SvO2 showed a bias toward CO-oximetry of +3 percentage points; upper and lower limits of agreement were +11 percentage points (95% confidence interval [CI], 9-14) and -5 percentage points (95% CI, -8 to -3), respectively. The concordance rate was 92% (95% CI, 89-96).CONCLUSIONS:In conclusion, this first clinical application of a novel concept for noninvasive SvO2 monitoring without the need for a pulmonary artery catheter indicates that Capno-SvO2 generates absolute values and trending capacity in close agreement with the gold standard reference method.
引用
收藏
页码:781 / 788
页数:8
相关论文
共 50 条
  • [1] Capnodynamics - noninvasive cardiac output and mixed venous oxygen saturation monitoring in children
    Karlsson, Jacob
    Lonnqvist, Per-Arne
    FRONTIERS IN PEDIATRICS, 2023, 11
  • [2] Novel noninvasive estimation of mixed venous oxygen saturation by echocardiography and expired gas analysis
    Onoue, Takeshi
    Iwataki, Mai
    Araki, Masaru
    Akashi, Jun
    Kitano, Tetsuji
    Nabeshima, Yosuke
    Hei, Soshi
    Nagata, Yasufumi
    Hayashi, Atsushi
    Tsuda, Yuki
    Sonoda, Shinjo
    Fujino, Yoshihisa
    Levine, Robert A.
    Otsuji, Yutaka
    AMERICAN JOURNAL OF PHYSIOLOGY-HEART AND CIRCULATORY PHYSIOLOGY, 2020, 319 (05): : H1078 - H1086
  • [3] Noninvasive Cerebral Oximeter as a Surrogate for Mixed Venous Saturation in Children
    Adnan T. Bhutta
    Jesse W. Ford
    James G. Parker
    Parthak Prodhan
    Eudice E. Fontenot
    Paul M. Seib
    Brittany I. Stroope
    Elizabeth A. Frazier
    Michael L. Schmitz
    Jonathan J. Drummond-Webb
    William R. Morrow
    Pediatric Cardiology, 2007, 28 : 34 - 41
  • [4] POSTOPERATIVE MIXED VENOUS OXYGEN-SATURATION MONITORING
    BARON, JF
    BENSOUDA, A
    CORIAT, P
    ACP-APPLIED CARDIOPULMONARY PATHOPHYSIOLOGY, 1988, 2 (04): : 327 - 332
  • [5] Noninvasive cerebral oximeter as a surrogate for mixed venous saturation in children
    Bhutta, Adnan T.
    Ford, Jesse W.
    Parker, James G.
    Prodhan, Parthak
    Fontenot, Eudice E.
    Seib, Paul M.
    Stroope, Brittany I.
    Frazier, Elizabeth A.
    Schmitz, Michael L.
    Drummond-Webb, Jonathan J.
    Morrow, William R.
    PEDIATRIC CARDIOLOGY, 2007, 28 (01) : 34 - 41
  • [6] CONTINUOUS MONITORING OF MIXED VENOUS OXYGEN SATURATION IN MAN
    MARTIN, WE
    CHEUNG, PW
    JOHNSON, CC
    WONG, KC
    ANESTHESIA AND ANALGESIA, 1973, 52 (05): : 784 - 793
  • [7] CONTINUOUS MONITORING OF MIXED VENOUS OXYGEN-SATURATION
    YANG, SC
    DEXTER, JR
    WESTERN JOURNAL OF MEDICINE, 1986, 144 (03): : 346 - 347
  • [8] CONTINUOUS MONITORING OF MIXED VENOUS OXYGEN-SATURATION
    DIVERTIE, MB
    MCMICHAN, JC
    CHEST, 1984, 85 (03) : 423 - 428
  • [9] CONTINUOUS MONITORING OF MIXED VENOUS OXYGEN-SATURATION
    JOURNOIS, D
    SAFRAN, D
    ANNALES FRANCAISES D ANESTHESIE ET DE REANIMATION, 1993, 12 (04): : 393 - 408
  • [10] Continuous monitoring of the central venous oxygen saturation in surgical patients: Comparison to the monitoring of the mixed venous saturation
    Cohendy, R
    Peries, C
    Lefrant, JY
    Doucot, PY
    Saissi, G
    Eledjam, JJ
    ACTA ANAESTHESIOLOGICA SCANDINAVICA, 1996, 40 (08) : 956 - 956