Biomechanical Comparison of Fixation Methods for Posterior Wall Fractures of the Acetabulum: Conventional Reconstruction Plate vs. Spring Plate vs. Variable Angle Locking Compression Plate

被引:0
|
作者
Chung, Hoejeong [1 ]
Sohn, Hoon-Sang [1 ]
Oh, Jong-Keon [2 ]
Lee, Sangho [1 ]
Kim, Doosup [1 ]
机构
[1] Yonsei Univ, Wonju Severance Christian Hosp, Wonju Coll Med, Dept Orthoped Surg, 20 Ilsan Ro, Wonju 26426, South Korea
[2] Korea Univ, Korea Univ Med, Guro Hosp, Dept Orthopaed Surg, 148 Gurodong Ro, Seoul 08308, South Korea
来源
MEDICINA-LITHUANIA | 2024年 / 60卷 / 06期
基金
新加坡国家研究基金会;
关键词
biomechanics; acetabulum; posterior wall fracture; variable angle plate; INTERNAL-FIXATION; HIP;
D O I
10.3390/medicina60060882
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background and Objectives: Acetabular fractures, though infrequent, present considerable challenges in treatment due to their association with high-energy trauma and poor prognoses. Posterior wall fractures, the most common type among them, typically have a more favorable prognosis compared to other types. Anatomical reduction and stable fixation of the posterior wall are crucial for optimal treatment outcomes. This study aimed to biomechanically compare three commonly used fixation methods for posterior wall fractures of the acetabulum-a conventional reconstruction plate, a spring plate, and a 2.7 mm variable angle locking compression plate (VA-LCP). Materials and Methods: The study utilized 6 fresh-frozen cadavers, yielding 12 hemipelvises free from prior trauma or surgery. Three fixation methods were compared using a simple acetabulum posterior wall fracture model. Fixation was performed by an orthopedic specialist, with prebending of plates to minimize errors. Hemipelvises were subjected to quasi-static and cyclic loading tests, measuring fracture gap, stiffness, and displacement under load. Results: It showed no significant differences in fracture gap among the three fixation methods under cyclic loading conditions simulating walking. However, the conventional reconstruction plate exhibited a greater stiffness compared to the spring and variable angle plates. Fatigue analysis revealed no significant differences among the plates, indicating a similar stability throughout cyclic loading. Despite differences in stiffness, all three fixation methods demonstrated adequate stability under loading conditions. Conclusions: While the conventional reconstruction plate demonstrated a superior stiffness, all three fixation methods provided sufficient stability under cyclic loading conditions similar to walking. This suggests that postoperative limitations are unlikely with any of the three methods, provided excessive activities are avoided. Furthermore, the variable angle plate-like the spring plate-offers an appropriate stability for fragment-specific fixation, supporting its use in surgical applications. These findings contribute to understanding the biomechanical performance of different fixation methods for acetabular fractures, facilitating improved surgical outcomes in challenging cases.
引用
收藏
页数:12
相关论文
共 50 条
  • [41] Middle third clavicular fractures fixed with precontoured locking compression plate or reconstruction plate: comparison of outcomes and complications
    Kariya, Ankur D.
    Jain, Pramod A.
    Patond, Kisan
    CURRENT ORTHOPAEDIC PRACTICE, 2019, 30 (03): : 257 - 262
  • [42] In vitro biomechanical comparison of locking compression plate fixation and limited-contact dynamic compression plate fixation of osteotomized equine third metacarpal bones
    Sod, Gary A.
    Mitchell, Colin F.
    Hubert, Jeremy D.
    Martin, George S.
    Gill, Marjorie S.
    VETERINARY SURGERY, 2008, 37 (03) : 283 - 288
  • [43] Osteosynthesis of type III acromial fractures with locking compression plate, lateral clavicular plate, and reconstruction plate: a biomechanical analysis of load to failure and strain distribution
    Kicinski, Maciej
    Puskas, Gabor J.
    Zdravkovic, Vilijam
    Jost, Bernhard
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2018, 27 (11) : 2093 - 2098
  • [44] A biomechanical comparison of conventional versus an anatomic plate and compression bolts for fixation of intra-articular calcaneal fractures
    Wang, Haili
    Yang, Zhaoxu
    Wu, Zhanpo
    Chen, Wei
    Zhang, Qi
    Li, Ming
    Li, Zhiyong
    Zhang, Yingze
    JOURNAL OF HUAZHONG UNIVERSITY OF SCIENCE AND TECHNOLOGY-MEDICAL SCIENCES, 2012, 32 (04) : 571 - 575
  • [45] A biomechanical comparison of conventional versus an anatomic plate and compression bolts for fixation of intra-articular calcaneal fractures
    Haili Wang
    Zhaoxu Yang
    Zhanpo Wu
    Wei Chen
    Qi Zhang
    Ming Li
    Zhiyong Li
    Yingze Zhang
    Journal of Huazhong University of Science and Technology [Medical Sciences], 2012, 32 : 571 - 575
  • [46] Anterior fixation of cervical spine: Bicortical screw-plate vs. monocortical self-locking systems
    Ceddia, A
    Carraturo, S
    Guglielmi, G
    Cammisa, M
    DAngelo, V
    11TH INTERNATIONAL CONGRESS OF NEUROLOGICAL SURGERY, VOLS 1 AND 2, 1997, : 1465 - 1469
  • [47] Biomechanical comparison of dynamic condylar screw and locking compression plate fixation in unstable distal femoral fractures: An in vitro study
    Ashutosh Kumar Singh
    Amit Rastogi
    Vakil Singh
    Indian Journal of Orthopaedics, 2013, 47 : 615 - 620
  • [48] Biomechanical comparison of dynamic condylar screw and locking compression plate fixation in unstable distal femoral fractures: An in vitro study
    Singh, Ashutosh Kumar
    Rastogi, Amit
    Singh, Vakil
    INDIAN JOURNAL OF ORTHOPAEDICS, 2013, 47 (06) : 615 - 620
  • [49] Intramedullary nailing vs. locking plate osteosynthesis in proximal humeral fractures. Long-term outcome
    von Rueden, C.
    Trapp, O.
    Hierholzer, C.
    Prohaska, S.
    Wurm, S.
    Buehren, V.
    UNFALLCHIRURG, 2015, 118 (08): : 686 - 692
  • [50] Biomechanical Comparison of Polyaxial-Type Locking Plates and a Fixed-Angle Locking Plate for Internal Fixation of Distal Femur Fractures
    Otto, Randall J.
    Moed, Berton R.
    Bledsoe, J. Gary
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2009, 23 (09) : 645 - 652