Human relevance of in vivo and in vitro skin irritation tests for hazard classification of pesticides

被引:0
|
作者
Raabe, Hans A. [1 ]
Costin, Gertrude-Emilia [1 ]
Allen, David G. [2 ]
Lowit, Anna [3 ]
Corvaro, Marco [4 ]
O'Dell, Lindsay [3 ]
Breeden-Alemi, Julie [3 ]
Page, Kathryn [5 ]
Perron, Monique [3 ]
Silva, Tara Flint [3 ]
Westerink, Walter [6 ]
Baker, Elizabeth [7 ]
Sullivan, Kristie [1 ]
机构
[1] Inst In Vitro Sci, Gaithersburg, MD 20878 USA
[2] Inotiv, Durham, NC USA
[3] US EPA, Washington, DC USA
[4] Corteva Agrisci, Rome, Italy
[5] Clorox Co, San Francisco, CA USA
[6] Charles River Labs, Den Bosch, Netherlands
[7] Phys Comm Responsible Med, Washington, DC USA
关键词
skin irritation; skin corrosion; new approach methodologies; reconstructed human epidermis; pesticide; formulation; cytokine release; non-animal; RECONSTRUCTED HUMAN EPIDERMIS; PERCUTANEOUS-ABSORPTION; CORROSIVITY TEST; PATCH TEST; MODEL; VALIDATION; INFLAMMATION; MECHANISMS; IL-1-ALPHA; TOXICITY;
D O I
10.1080/15569527.2024.2387596
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Background: Test methods to inform hazard characterization and labeling of pesticides to protect human health are typically conducted using laboratory animals, and for skin irritation/corrosion the rabbit Draize test is currently required by many regulatory agencies. Although the Draize test is generally regarded to provide protective classifications for human health, new approach methodologies (NAMs) have been developed that offer more human relevant models that circumvent the uncertainty associated with species differences that exist between rabbits and humans. Despite wide applicability and use of these test methods across a broad range of chemicals, they have not been widely adopted for testing pesticides and pesticidal formulations. One of the barriers to adoption of these methods in this sector is low concordance with results from the Draize rabbit test, particularly for chemicals within the mild to moderate irritation spectrum.Methods: This review compares and contrasts the extent to which available models used in skin irritation testing mimic the anatomy and physiology of human skin, and how each aligns with the known key events leading to chemically-induced adverse skin irritation and corrosion. Doing so fully characterizes the human relevance of each method.Results: As alternatives to the rabbit Draize test, several protocols using ex vivo, in chemico, and in vitro skin models are available as internationally harmonized test guidelines. These methods rely on a variety of models of human skin, including excised rodent skin, synthetic biochemical models of barrier function, cell culture systems, and reconstructed human tissue models. We find these models exhibit biological and mechanistic relevance aligned with human skin irritation responses. Further, recent retrospective analyses have shown that the reproducibility of the Draize test is less than 50% for mild and moderate responses, with many of the replicate predictions spanning more than one category (e.g., a moderate response reported in one study followed by a non-irritant response reported in another study).Conclusions: Based on this comparative evaluation, we recommend top-down and bottom-up testing strategies that use the most human relevant in vitro test methods for skin irritation and corrosion classification of pesticides and pesticide formulations. To further discriminate among mild and non-irritant formulations, optimization of a cytokine release protocol and subsequent analyses of reference formulation test results is recommended.
引用
收藏
页码:1 / 21
页数:21
相关论文
共 50 条
  • [31] In vitro skin irritation and corrosion testing serving different regulatory classification schemes
    Kolle, S.
    Mehling, A.
    van Ravenzwaay, B.
    Landsiedel, R.
    NAUNYN-SCHMIEDEBERGS ARCHIVES OF PHARMACOLOGY, 2012, 385 : 47 - 47
  • [32] Applicability of in vitro tests for skin irritation and corrosion to regulatory classification schemes: Substantiating test strategies with data from routine studies
    Kolle, Susanne N.
    Sullivan, Kristie M.
    Mehling, Annette
    van Ravenzwaay, Bennard
    Landsiedel, Robert
    REGULATORY TOXICOLOGY AND PHARMACOLOGY, 2012, 64 (03) : 402 - 414
  • [33] Ex Vivo Human Skin: An Alternative Test System for Skin Irritation and Corrosion Assays
    Eberlin, Samara
    Facchini, Gustavo
    da Silva, Gustavo Henrique
    Eberlin, Samir
    Bragatto, Aline Rodrigues
    Tabarini Alves Pinheiro, Ana Lucia
    Pinheiro, Adriano da Silva
    ATLA-ALTERNATIVES TO LABORATORY ANIMALS, 2021, 49 (04): : 137 - 146
  • [34] Human acute skin irritation and sensitization potentials, in vivo:: GlucoWatch® biographer
    Wilson, DR
    Potts, RO
    Ackerman, NR
    Fermi, S
    DIABETES, 2000, 49 : A129 - A129
  • [35] Follow-up to the ECVAM prevalidation study on in vitro tests for acute skin irritation -: ECVAM Skin Irritation Task Force report 2
    Zuang, V
    Balls, M
    Botham, PA
    Coquette, A
    Corsini, E
    Curren, RD
    Elliott, GR
    Fentem, JH
    Heylings, JR
    Liebsch, M
    Medina, J
    Roguet, R
    van de Sandt, JJM
    Wiemann, C
    Worth, AP
    ATLA-ALTERNATIVES TO LABORATORY ANIMALS, 2002, 30 (01): : 109 - 129
  • [36] Evaluation of a human patch test for the identification and classification of skin irritation potential
    York, M
    Griffiths, HA
    Whittle, E
    Basketter, DA
    CONTACT DERMATITIS, 1996, 34 (03) : 204 - 212
  • [37] In vitro human skin irritation test for evaluation of medical device extracts
    Casas, J. W.
    Lewerenz, G. M.
    Rankin, E. A.
    Willoughby, J. A., Sr.
    Blakeman, L. C.
    McKim, J. M., Jr.
    Coleman, K. P.
    TOXICOLOGY IN VITRO, 2013, 27 (08) : 2175 - 2183
  • [38] A prevalidation study on in vitro tests for acute skin irritation:: results and evaluation by the Management Team
    Fentem, JH
    Briggs, D
    Chesné, C
    Elliott, GR
    Harbell, JW
    Heylings, JR
    Portes, P
    Roguet, R
    van de Sandt, JJM
    Botham, PA
    TOXICOLOGY IN VITRO, 2001, 15 (01) : 57 - 93
  • [39] A prevalidation study on the in vitro skin irritation function test (SIFT) for prediction of acute skin irritation in vivo: results and evaluation of ECVAM Phase III
    Heylings, JR
    Diot, S
    Esdaile, DJ
    Fasano, WJ
    Manning, LA
    Owen, HM
    TOXICOLOGY IN VITRO, 2003, 17 (02) : 123 - 138
  • [40] KeraSkin™-VM: A novel reconstructed human epidermis model for skin irritation tests
    Jung, Kyoung-Mi
    Lee, Su-Hyon
    Jang, Won-Hee
    Jung, Haeng-Sun
    Heo, Yong
    Park, Young-Ho
    Bae, SeungJin
    Lim, Kyung-Min
    Seok, Seung Hyeok
    TOXICOLOGY IN VITRO, 2014, 28 (05) : 742 - 750