Applicability of in vitro tests for skin irritation and corrosion to regulatory classification schemes: Substantiating test strategies with data from routine studies

被引:8
|
作者
Kolle, Susanne N. [1 ]
Sullivan, Kristie M. [2 ]
Mehling, Annette [3 ]
van Ravenzwaay, Bennard [1 ]
Landsiedel, Robert [1 ]
机构
[1] BASF SE, D-67056 Ludwigshafen, Germany
[2] Phys Comm Responsible Med, Washington, DC 20016 USA
[3] BASF Personal Care & Nutr GmbH, D-40589 Dusseldorf, Germany
关键词
Skin irritation; Skin corrosion; Routine testing; In vitro; RhE; EpiDerm; OECD TG 431; OECD TG 439; Predictivity; BOVINE CORNEAL OPACITY; PERMEABILITY TEST; HUMAN EPIDERMIS; PATCH TEST; VALIDATION; VALIDITY; ASSAYS;
D O I
10.1016/j.yrtph.2012.08.015
中图分类号
DF [法律]; D9 [法律]; R [医药、卫生];
学科分类号
0301 ; 10 ;
摘要
Skin corrosion or irritation refers to the production of irreversible or reversible damage to the skin following the application of a test substance, respectively. Traditionally, hazard assessments are conducted using the in vivo Draize skin test, but recently in vitro tests using reconstructed human epidermis (RhE) models have gained regulatory acceptance. In this study, skin corrosion (SCT) and irritation tests (SIT) using a RhE model were implemented to reduce the number of in vivo tests required by regulatory bodies. One hundred and thirty-four materials were tested from a wide range of substance classes included 46 agrochemical formulations. Results were assessed according to UN GHS, EU-CLP, ANVISA and US EPA classification schemes. There was high correlation between the two in vitro tests. Assessment of the SCT sensitivity was not possible due to the limited number of corrosives in the data set; SCT specificity and accuracy were 89% for all classification systems. Accuracy (63-76%) and sensitivity (53-67%) were low in the SIT. Specificity and concordance for agrochemical formulations alone in both the SCT and SIT were comparable to the values for the complete data set (SCT: 91% vs. 89% specificity, 91% vs. 89% accuracy and SIT: 64-88% vs. 70-85% specificity, 56-75% vs. 63-76% accuracy). (C) 2012 Elsevier Inc. All rights reserved.
引用
收藏
页码:402 / 414
页数:13
相关论文
共 10 条
  • [1] Applicability of in vitro tests for skin irritation and corrosion to regulatory classification schemes: Substantiating test strategies with data from routine studies (vol 65, pg 366, 2103)
    Kolle, Susanne N.
    Sullivan, Kristie M.
    Mehling, Annette
    van Ravenzwaay, Bennard
    Landsiedel, Robert
    REGULATORY TOXICOLOGY AND PHARMACOLOGY, 2013, 65 (03) : 366 - 378
  • [2] In vitro skin irritation and corrosion testing serving different regulatory classification schemes
    Kolle, S.
    Mehling, A.
    van Ravenzwaay, B.
    Landsiedel, R.
    NAUNYN-SCHMIEDEBERGS ARCHIVES OF PHARMACOLOGY, 2012, 385 : 47 - 47
  • [3] Limited applicability of in vitro skin corrosion and irritation tests for agrochemical formulations
    Kolle, Susanne N.
    van Ravenzwaay, Ben
    Landsiedel, Robert
    TOXICOLOGY LETTERS, 2017, 280 : S274 - S274
  • [4] Limited applicability of in vitro skin corrosion and irritation tests for agrochemical formulations
    Kolle, S.
    Remmele, M.
    van Ravenzwaay, B.
    Landsiedel, R.
    NAUNYN-SCHMIEDEBERGS ARCHIVES OF PHARMACOLOGY, 2018, 391 : S81 - S81
  • [5] Introduction of SAR considerations and specific in vitro tests into skin and eye irritation/corrosion testing strategies
    Gerner, I
    Zinke, S
    ALTEX-ALTERNATIVEN ZU TIEREXPERIMENTEN, 1999, 16 (03): : 175 - 175
  • [6] Regulatory assessment of in vitro skin corrosion and irritation data within the European framework: Workshop recommendations
    Eskes, Cnantra
    Detappe, Veronique
    Koeter, Herman
    Kreysa, Joachim
    Liebsch, Manfred
    Zuang, Valerie
    Arncoff, Patric
    Barroso, Joao
    Cotovio, Jose
    Guest, Robert
    Hermann, Martina
    Hoffmann, Sebastian
    Masson, Philippe
    Alepee, Nathalie
    Arce, Luis Alfonso
    Brueschweiler, Beat
    Catone, Tiziana
    Cihak, Rostislav
    Clouzeau, Jack
    D'Abrosca, Federica
    Delveaux, Cedric
    Derouette, Jean Paul
    Engelking, Oliver
    Facchini, Davide
    Froehlicher, Mirjam
    Hofmann, Markus
    Hopf, Nancy
    Molinari, Jennifer
    Oberli, Aurelia
    Ott, Matthieu
    Peter, Ronald
    Sa-Rocha, Vanessa M.
    Schenk, Dominique
    Tomicic, Catherine
    Vanparys, Philippe
    Verdon, Bernadette
    Wallenhorst, Thomas
    Winkler, Gian Christian
    Depallens, Olivier
    REGULATORY TOXICOLOGY AND PHARMACOLOGY, 2012, 62 (02) : 393 - 403
  • [7] Skin irritation: prevalence, variability, and regulatory classification of existing in vivo data from industrial chemicals
    Hoffmann, S
    Cole, T
    Hartung, T
    REGULATORY TOXICOLOGY AND PHARMACOLOGY, 2005, 41 (03) : 159 - 166
  • [8] From skin corrosion to skin irritation:: Epidermal Skin Test 1000 (EST-1000) -: A reliable tool for hazard identification in vitro
    Hoffmann, Jens J.
    Heisler, Eckhard
    Losse, Jan
    Thomas, Diemo
    Fuchs, Horst W.
    TOXICOLOGY LETTERS, 2006, 164 : S222 - S223
  • [9] Comparative assessment of 24-hr primary skin irritation test and human patch test data with in vitro skin irritation tests according to OECD Test Guideline 439 (for quasi-drugs in Japan)
    Sugiyama, Mariko
    Akita, Masaharu
    Alepee, Nathalie
    Fujishiro, Miyuki
    Hagino, Shigenobu
    Handa, Yuki
    Ikeda, Hidefumi
    Imai, Noriyasu
    Jitsukawa, Setsuko
    Katoh, Masakazu
    Kurihara, Koji
    Kyotani, Daiki
    Nomura, Shigeyuki
    Okamoto, Yuko
    Okumura, Hidenobu
    Omori, Takashi
    Sugibayashi, Kenji
    Todo, Hiroaki
    Toyoda, Akemi
    Ohno, Yasuo
    JOURNAL OF TOXICOLOGICAL SCIENCES, 2018, 43 (10-12): : 751 - 768
  • [10] The EpiOcular™ Eye Irritation Test is the Method of Choice for the In Vitro Eye Irritation Testing of Agrochemical Formulations: Correlation Analysis of EpiOcular Eye Irritation Test and BCOP Test Data According to the UN GHS, US EPA and Brazil ANVISA Classification Schemes
    Kolle, Susanne N.
    Moreno, Maria Cecilia Rey
    Mayer, Winfried
    van Cott, Andrew
    van Ravenzwaay, Bennard
    Landsiedel, Robert
    ATLA-ALTERNATIVES TO LABORATORY ANIMALS, 2015, 43 (03): : 181 - 198