Use of Color Channel Optimization in 3D Heads-Up Vitrectomy vs Standard Operating Microscope for Macular Surgeries

被引:0
|
作者
Agarwal, Aniruddha [1 ,2 ,3 ]
Ghazi, Nicola [1 ,2 ]
El Ghrably, Ibraheem [1 ,2 ]
Iovino, Claudio [4 ]
Peiretti, Enrico [5 ]
Alcibahy, Yasmine [1 ,6 ]
Menia, Nitin Kumar [7 ]
Chhablani, Jay [8 ]
Pichi, Francesco [1 ,2 ]
Grewal, Dilraj [9 ]
机构
[1] Cleveland Clin Abu Dhabi, Eye Inst, 59 Hamouda Bin Ali Al Dhaheri St, Abu Dhabi, U Arab Emirates
[2] Cleveland Clin, Lerner Coll Med, Cleveland, OH USA
[3] Maastricht Univ, Med Ctr, Dept Ophthalmol, Maastricht, Netherlands
[4] Univ Campania Luigi Vanvitelli, Eye Clin, Multidisciplinary Dept Med Surg & Dent Sci, Naples, Italy
[5] Univ Cagliari, Dept Surg Sci, Eye Clin, Cagliari, Italy
[6] Med Univ Bahrain, Royal Coll Surg Ireland, Adliya, Bahrain
[7] All India Inst Med Sci, Dept Ophthalmol, Jammu, India
[8] Univ Pittsburgh, Med Ctr, Eye Ctr, Pittsburgh, PA USA
[9] Duke Univ, Sch Med, Duke Eye Ctr, Durham, NC USA
关键词
color channels; 3D heads-up vitrectomy; standard operating microscope; internal limiting membrane; external limiting membrane; VISUAL IMPAIRMENT;
D O I
10.1177/24741264241263457
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To compare the efficacy and safety of color channel optimization with 3-dimensional (3D) heads-up vitrectomy (3D HUD group) vs standard operating microscope vitrectomy (control group) for macular surgery. Methods: This retrospective multicenter comparative study comprised patients having 25-gauge pars plana vitrectomy for macular hole, epiretinal membrane (ERM), or vitreomacular traction. The minimum follow-up was 6 months. Surgeons completed a subjective questionnaire after each case. The main outcome measures were safety related (dye reinjection rate, macular ERM or internal limiting membrane [ILM] peeling time, endoillumination intensity). Other outcome measures included total surgical time, surgical outcomes, and subjective surgeon-related parameters. Results: The study included 74 eyes (36 in 3D HUD group; 38 in control group). There were no statistical differences in baseline parameters between groups. Significantly more eyes in the control group than in the 3D HUD group required dye reinjection (23.7% vs 5.6%; P = .03). Less time was required for ERM and ILM peeling in the 3D HUD group (both P < .01); however, the total surgical time was the same between groups. Eyes in the 3D HUD group required lower endoillumination (P < .001). There were no between-group differences in the rates of complications. Surgeons said depth perception was better in the control group (P < .001), with no differences in comfort or visibility. Conclusions: 3D heads-up-based color channel optimization for macular surgeries is safe and effective. Although it may have safety advantages, it did not affect the visual or anatomic outcomes or total surgical time and did not improve surgeon comfort or visibility.
引用
收藏
页码:517 / 523
页数:7
相关论文
共 44 条
  • [1] 3D Heads-Up Display vs. Standard Operating Microscope Vitrectomy for Rhegmatogenous Retinal Detachment
    Asani, Ben
    Siedlecki, Jakob
    Schworm, Benedikt
    Mayer, Wolfgang J.
    Kreutzer, Thomas C.
    Luft, Nikolaus
    Priglinger, Siegfried G.
    FRONTIERS IN MEDICINE, 2020, 7
  • [2] Comparing clinical outcomes of macular hole surgeries performed by trainee surgeons using a 3D heads-up display viewing system versus a standard operating microscope
    Subhakar Reddy
    Kushanth Mallikarjun
    Ashik Mohamed
    Prithvi Mruthyunjaya
    Vivek Pravin Dave
    Rajeev Reddy Pappuru
    Jay Chhablani
    Raja Narayanan
    International Ophthalmology, 2021, 41 : 2649 - 2655
  • [3] Comparing clinical outcomes of macular hole surgeries performed by trainee surgeons using a 3D heads-up display viewing system versus a standard operating microscope
    Reddy, Subhakar
    Mallikarjun, Kushanth
    Mohamed, Ashik
    Mruthyunjaya, Prithvi
    Dave, Vivek Pravin
    Pappuru, Rajeev Reddy
    Chhablani, Jay
    Narayanan, Raja
    INTERNATIONAL OPHTHALMOLOGY, 2021, 41 (08) : 2649 - 2655
  • [4] Comparison of clinical outcomes between "heads-up" 3D viewing system and conventional microscope in macular hole surgeries: A pilot study
    Kumar, Atul
    Hasan, Nasiq
    Kakkar, Prateek
    Mutha, Vineet
    Karthikeya, R.
    Sundar, Dheepak
    Ravani, Raghav
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2018, 66 (12) : 1816 - 1819
  • [5] Comparison of a Three-Dimensional Heads-Up Display Surgical Platform with a Standard Operating Microscope for Macular Surgery
    Talcott, Katherine E.
    Adam, Murtaza K.
    Sioufi, Kareem
    Aderman, Christopher M.
    Ali, Ferhina S.
    Mellen, Phoebe L.
    Garg, Sunir J.
    Hsu, Jason
    Ho, Allen C.
    OPHTHALMOLOGY RETINA, 2019, 3 (03): : 244 - 251
  • [6] COST SAVINGS ASSOCIATED WITH USE OF 3D HEADS-UP DISPLAY (3D-HUD) IN MACULAR HOLE SURGERIES: AN ACADEMIC HOSPITAL PERSPECTIVE
    Siegfried, C.
    Duca, O.
    Mark, N.
    Pan, L. C.
    Hsiao, C. C.
    VALUE IN HEALTH, 2024, 27 (06) : S81 - S81
  • [7] Commentary: 3D heads-up surgeries: Backing our backs, and necks!
    Joshi, Shrinivas
    Vibhute, Giriraj
    Ayachit, Guruprasad
    Ayachit, Apoorva
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2022, 70 (03) : 851 - 851
  • [8] Comparison of the Safety and Efficacy of a 3-Dimensional Heads-up Display vs a Standard Operating Microscope in Retinal Detachment Repair
    Zeng, Rebecca
    Feng, Yilin
    Begaj, Tedi
    Baldwin, Grace
    Miller, John B. B.
    JOURNAL OF VITREORETINAL DISEASES, 2023, 7 (02) : 97 - 102
  • [9] Evaluation of 3D heads-up vitrectomy: outcomes of psychometric skills testing and surgeon satisfaction
    Mario R. Romano
    Gilda Cennamo
    Chiara Comune
    Michela Cennamo
    Mariantonia Ferrara
    Luca Rombetto
    Giovanni Cennamo
    Eye, 2018, 32 : 1093 - 1098
  • [10] Evaluation of 3D heads-up vitrectomy: outcomes of psychometric skills testing and surgeon satisfaction
    Romano, Mario R.
    Cennamo, Gilda
    Comune, Chiara
    Cennamo, Michela
    Ferrara, Mariantonia
    Rombetto, Luca
    Cennamo, Giovanni
    EYE, 2018, 32 (06) : 1093 - 1098