Comparison of the Safety and Efficacy of a 3-Dimensional Heads-up Display vs a Standard Operating Microscope in Retinal Detachment Repair

被引:2
|
作者
Zeng, Rebecca [1 ,2 ]
Feng, Yilin [1 ,2 ]
Begaj, Tedi [1 ]
Baldwin, Grace [1 ,2 ]
Miller, John B. B. [1 ,2 ,3 ]
机构
[1] Harvard Med Sch, Massachusetts Eye & Ear, Dept Ophthalmol, Harvard Retinal Imaging Lab, Boston, MA 02114 USA
[2] Harvard Med Sch, Massachusetts Eye & Ear, Dept Ophthalmol, Retina Serv, Boston, MA 02114 USA
[3] Harvard Med Sch, Massachusetts Eye & Ear Infirm, 243 Charles St, Boston, MA 02114 USA
关键词
3D heads-up display; Ngenuity; retinal detachment; visualization systems; vitreoretinal surgery; pars plana vitrectomy; SURGERY;
D O I
10.1177/24741264221150074
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To evaluate the safety, efficacy, and efficiency of the Ngenuity 3-dimensional (3D) heads-up display (HUD) visualization system for primary rhegmatogenous retinal detachment (RRD) repair at a large academic medical center in the United States. Methods: This retrospective review comprised consecutive patients aged 18 years or older who had primary RRD repair (pars plana vitrectomy [PPV] alone or combined PPV and scleral buckle) performed by the same fellowship-trained vitreoretinal surgeon using the 3D visualization system and a traditional standard operating microscope (SOM) at Massachusetts Eye and Ear from June 2017 to December 2021. The minimum follow-up was 90 days. Results: The 3D HUD group comprised 50 eyes of 47 patients and the SOM group, 138 eyes of 136 patients. There were no between-group differences in single surgery anatomic success rates at 3 months (98% HUD vs 99% SOM; P = 1.00) or at the last follow-up (94% HUD vs 98% SOM; P = .40). The rate of postoperative proliferative vitreoretinopathy was similar between the 2 groups (3 months: 3% HUD vs 5% SOM, P = .94; last follow-up, 2% HUD vs 3% SOM, P = .93). There was no difference in the mean duration of surgery (57.4 +/- 28.9 minutes HUD vs 59.4 +/- 29.9 minutes SOM; P = .68). Conclusions: Anatomic and functional outcomes, in addition to surgical efficiency, of noncomplex primary RRD repair with a 3D HUD system were similar to those of surgery performed with an SOM.
引用
收藏
页码:97 / 102
页数:6
相关论文
共 27 条
  • [1] 3D Heads-Up Display vs. Standard Operating Microscope Vitrectomy for Rhegmatogenous Retinal Detachment
    Asani, Ben
    Siedlecki, Jakob
    Schworm, Benedikt
    Mayer, Wolfgang J.
    Kreutzer, Thomas C.
    Luft, Nikolaus
    Priglinger, Siegfried G.
    FRONTIERS IN MEDICINE, 2020, 7
  • [2] Comparison of a Three-Dimensional Heads-Up Display Surgical Platform with a Standard Operating Microscope for Macular Surgery
    Talcott, Katherine E.
    Adam, Murtaza K.
    Sioufi, Kareem
    Aderman, Christopher M.
    Ali, Ferhina S.
    Mellen, Phoebe L.
    Garg, Sunir J.
    Hsu, Jason
    Ho, Allen C.
    OPHTHALMOLOGY RETINA, 2019, 3 (03): : 244 - 251
  • [3] Use of Color Channel Optimization in 3D Heads-Up Vitrectomy vs Standard Operating Microscope for Macular Surgeries
    Agarwal, Aniruddha
    Ghazi, Nicola
    El Ghrably, Ibraheem
    Iovino, Claudio
    Peiretti, Enrico
    Alcibahy, Yasmine
    Menia, Nitin Kumar
    Chhablani, Jay
    Pichi, Francesco
    Grewal, Dilraj
    JOURNAL OF VITREORETINAL DISEASES, 2024, 8 (05) : 517 - 523
  • [4] Three-Dimensional Heads-Up vs. Standard Operating Microscope for Cataract Surgery: A Systematic Review and Meta-Analysis
    Ripa, Matteo
    Kopsacheilis, Nikolaos
    Kanellopoulou, Kanellina
    Nomikarios, Mikes
    Motta, Lorenzo
    DIAGNOSTICS, 2022, 12 (09)
  • [5] Comparison of Ergonomics in Vitreoretinal Surgery With Heads-up Visualization Versus the Standard Operating Microscope as Measured by a Wearable Device
    Moon, Jade Y.
    Seddon, Ian
    Sokol, Jared T.
    Zeng, Rebecca
    Ludwig, Cassie A.
    Wu, Frances
    Rahimy, Ehsan
    Houston, Steven K.
    Miller, John B.
    OPHTHALMIC SURGERY LASERS & IMAGING RETINA, 2024, 55 (11): : 638 - 645
  • [6] Heads-up 3D vision system for retinal detachment surgery
    Michele Coppola
    Carlo La Spina
    Alessandro Rabiolo
    Giuseppe Querques
    Francesco Bandello
    International Journal of Retina and Vitreous, 3 (1)
  • [7] Comparative Assessment of Ergonomic Experience with Heads-Up Display and Conventional Surgical Microscope in the Operating Room
    Weinstock, Robert J.
    Ainslie-Garcia, Margaret H.
    Ferko, Nicole C.
    Qadeer, Rana A.
    Morris, Leighton P.
    Cheng, Hang
    Ehlers, Justis P.
    CLINICAL OPHTHALMOLOGY, 2021, 15 : 347 - 356
  • [8] Comparison of Descemet membrane endothelial keratoplasty (DMEK) with 3D heads -up display versus standard operating microscope
    Schiefelbein, Johannes
    Kruse, Franziska
    Siedlecki, Jakob
    Priglinger, Siegfried
    Asani, Ben
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2024, 65 (07)
  • [9] Digital 3D "Heads-up" Cataract Surgery: Safety Profile and Comparison with the Conventional Microscope System
    Bedar, Mohammad Seleman
    Kellner, Ulrich
    KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 2022, 239 (08) : 991 - 995
  • [10] Assessing the surgical competency of novice surgeons by using a three-dimensional heads-up display microscope
    Varman, Aadithreya
    Varman, N. V. Arulmozhi
    Balakumar, Dinesh
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2024, 72 (09) : 1329 - 1335