Use of Color Channel Optimization in 3D Heads-Up Vitrectomy vs Standard Operating Microscope for Macular Surgeries

被引:0
|
作者
Agarwal, Aniruddha [1 ,2 ,3 ]
Ghazi, Nicola [1 ,2 ]
El Ghrably, Ibraheem [1 ,2 ]
Iovino, Claudio [4 ]
Peiretti, Enrico [5 ]
Alcibahy, Yasmine [1 ,6 ]
Menia, Nitin Kumar [7 ]
Chhablani, Jay [8 ]
Pichi, Francesco [1 ,2 ]
Grewal, Dilraj [9 ]
机构
[1] Cleveland Clin Abu Dhabi, Eye Inst, 59 Hamouda Bin Ali Al Dhaheri St, Abu Dhabi, U Arab Emirates
[2] Cleveland Clin, Lerner Coll Med, Cleveland, OH USA
[3] Maastricht Univ, Med Ctr, Dept Ophthalmol, Maastricht, Netherlands
[4] Univ Campania Luigi Vanvitelli, Eye Clin, Multidisciplinary Dept Med Surg & Dent Sci, Naples, Italy
[5] Univ Cagliari, Dept Surg Sci, Eye Clin, Cagliari, Italy
[6] Med Univ Bahrain, Royal Coll Surg Ireland, Adliya, Bahrain
[7] All India Inst Med Sci, Dept Ophthalmol, Jammu, India
[8] Univ Pittsburgh, Med Ctr, Eye Ctr, Pittsburgh, PA USA
[9] Duke Univ, Sch Med, Duke Eye Ctr, Durham, NC USA
关键词
color channels; 3D heads-up vitrectomy; standard operating microscope; internal limiting membrane; external limiting membrane; VISUAL IMPAIRMENT;
D O I
10.1177/24741264241263457
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To compare the efficacy and safety of color channel optimization with 3-dimensional (3D) heads-up vitrectomy (3D HUD group) vs standard operating microscope vitrectomy (control group) for macular surgery. Methods: This retrospective multicenter comparative study comprised patients having 25-gauge pars plana vitrectomy for macular hole, epiretinal membrane (ERM), or vitreomacular traction. The minimum follow-up was 6 months. Surgeons completed a subjective questionnaire after each case. The main outcome measures were safety related (dye reinjection rate, macular ERM or internal limiting membrane [ILM] peeling time, endoillumination intensity). Other outcome measures included total surgical time, surgical outcomes, and subjective surgeon-related parameters. Results: The study included 74 eyes (36 in 3D HUD group; 38 in control group). There were no statistical differences in baseline parameters between groups. Significantly more eyes in the control group than in the 3D HUD group required dye reinjection (23.7% vs 5.6%; P = .03). Less time was required for ERM and ILM peeling in the 3D HUD group (both P < .01); however, the total surgical time was the same between groups. Eyes in the 3D HUD group required lower endoillumination (P < .001). There were no between-group differences in the rates of complications. Surgeons said depth perception was better in the control group (P < .001), with no differences in comfort or visibility. Conclusions: 3D heads-up-based color channel optimization for macular surgeries is safe and effective. Although it may have safety advantages, it did not affect the visual or anatomic outcomes or total surgical time and did not improve surgeon comfort or visibility.
引用
收藏
页码:517 / 523
页数:7
相关论文
共 44 条
  • [21] Excision of a median nerve schwannoma using the 3D microscope: a heads-up ergonomic approach to microsurgical tasks in hand surgery
    Sonia Ubong
    Theodora Papavasiliou
    Lauren Uppal
    European Journal of Plastic Surgery, 2022, 45 : 827 - 829
  • [22] Excision of a median nerve schwannoma using the 3D microscope: a heads-up ergonomic approach to microsurgical tasks in hand surgery
    Ubong, Sonia
    Papavasiliou, Theodora
    Uppal, Lauren
    EUROPEAN JOURNAL OF PLASTIC SURGERY, 2022, 45 (05) : 827 - 829
  • [23] Lights-out Surgery for Strabismus Using a Heads-Up 3D Vision System
    Hamasaki, Ichiro
    Shibata, Kiyo
    Shimizu, Takehiro
    Kono, Reika
    Morizane, Yuki
    Shiraga, Fumio
    ACTA MEDICA OKAYAMA, 2019, 73 (03) : 229 - 233
  • [24] 3D Heads-up vitreo-retinal surgery with intraoperative OCT and intraocular endoscopy
    Kitaoka, Takashi
    Hara, Yuki
    Matsumoto, Makiko
    Tsuiki, Eiko
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2017, 58 (08)
  • [25] Use of the heads-up NGENUITY 3D Visualization System for vitreoretinal surgery: a retrospective evaluation of outcomes in a French tertiary center
    Kantor, Pierre
    Matonti, Frederic
    Varenne, Fanny
    Sentis, Vanessa
    Pagot-Mathis, Veronique
    Fournie, Pierre
    Soler, Vincent
    SCIENTIFIC REPORTS, 2021, 11 (01)
  • [26] Use of the heads-up NGENUITY 3D Visualization System for vitreoretinal surgery: a retrospective evaluation of outcomes in a French tertiary center
    Pierre Kantor
    Frédéric Matonti
    Fanny Varenne
    Vanessa Sentis
    Véronique Pagot-Mathis
    Pierre Fournié
    Vincent Soler
    Scientific Reports, 11
  • [27] Image sharpening algorithms improve clarity of surgical field during 3D heads-up surgery
    Kosuke Nakajima
    Makoto Inoue
    Aya Takahashi
    Yuji Yoshikawa
    Masaharu Mizuno
    Takashi Koto
    Tomoka Ishida
    Tetsuro Oshika
    International Journal of Retina and Vitreous, 9
  • [28] Image sharpening algorithms improve clarity of surgical field during 3D heads-up surgery
    Nakajima, Kosuke
    Inoue, Makoto
    Takahashi, Aya
    Yoshikawa, Yuji
    Mizuno, Masaharu
    Koto, Takashi
    Ishida, Tomoka
    Oshika, Tetsuro
    INTERNATIONAL JOURNAL OF RETINA AND VITREOUS, 2023, 9 (01)
  • [29] Heads-up 3D eye surgery: Safety outcomes and technological review after 2 years of day-to-day use
    Del Turco, Claudia
    D'Amico Ricci, Giuseppe
    Dal Vecchio, Marco
    Bogetto, Caterina
    Panico, Edoardo
    Giobbio, Dora Cecilia
    Romano, Mario R.
    Panico, Claudio
    La Spina, Carlo
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2022, 32 (02) : 1129 - 1135
  • [30] EVALUATION OF THE RETINAL HAZARD WITH 3D DIGITALLY ASSISTED VISUALIZATION SYSTEM AND CONVENTIONAL MICROSCOPE IN MACULAR SURGERIES
    Horigome, Yuka
    Iwashita, Yume
    Hirono, Kazushi
    Inoue, Tatsuya
    Konno, Ami
    Kadonosono, Kazuaki
    Yanagi, Yasuo
    RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2022, 42 (12): : 2301 - 2306