Characterization of Cochlear Implant Artifact and Removal Based on Multi-Channel Wiener Filter in Unilateral Child Patients

被引:0
|
作者
Rossi, Dario [1 ]
Cartocci, Giulia [1 ,2 ]
Inguscio, Bianca M. S. [1 ,2 ]
Capitolino, Giulia [3 ]
Borghini, Gianluca [1 ,2 ]
Di Flumeri, Gianluca [1 ,2 ]
Ronca, Vincenzo [2 ,3 ]
Giorgi, Andrea [4 ]
Vozzi, Alessia [2 ]
Capotorto, Rossella [4 ]
Babiloni, Fabio [2 ,5 ,6 ]
Scorpecci, Alessandro [7 ]
Giannantonio, Sara [7 ]
Marsella, Pasquale [7 ]
Leone, Carlo Antonio [8 ]
Grassia, Rosa [8 ]
Galletti, Francesco [9 ]
Ciodaro, Francesco [9 ]
Galletti, Cosimo [9 ]
Arico, Pietro [2 ,3 ]
机构
[1] Sapienza Univ Rome, Dept Mol Med, Viale Regina Elena 291, I-00161 Rome, Italy
[2] BrainSigns srl, Via Tirso 14, I-00198 Rome, Italy
[3] Sapienza Univ Rome, Dept Comp Control & Management Engn Antonio Rubert, Piazzale Aldo Moro 5, I-00185 Rome, Italy
[4] Sapienza Univ Rome, Dept Anat Histol Forens & Orthoped Sci, Piazzale Aldo Moro 5, I-00185 Rome, Italy
[5] Sapienza Univ Rome, Dept Physiol & Pharmacol Vittorio Erspamer, Piazzale Aldo Moro 5, I-00185 Rome, Italy
[6] Hangzhou Dianzi Univ, Dept Comp Sci, Hangzhou 310018, Peoples R China
[7] Bambino Gesu Pediat Hosp & Res Inst, Audiol & Otosurgery Unit, Piazza Sant Onofrio 4, I-00165 Rome, Italy
[8] Monaldi Hosp, Dept Otolaringol Head Neck Surg, Via Leonardo Bianchi, I-80131 Naples, Italy
[9] Univ Messina, Dept Otorhinolaryngol, Piazza Pugliatti 1, I-98122 Messina, Italy
来源
BIOENGINEERING-BASEL | 2024年 / 11卷 / 08期
关键词
EEG; cochlear implant; cochlear implant artifact; multi-channel Wiener filter (MWF); artifact reduction;
D O I
10.3390/bioengineering11080753
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
Cochlear implants (CI) allow deaf patients to improve language perception and improving their emotional valence assessment. Electroencephalographic (EEG) measures were employed so far to improve CI programming reliability and to evaluate listening effort in auditory tasks, which are particularly useful in conditions when subjective evaluations are scarcely appliable or reliable. Unfortunately, the presence of CI on the scalp introduces an electrical artifact coupled to EEG signals that masks physiological features recorded by electrodes close to the site of implant. Currently, methods for CI artifact removal have been developed for very specific EEG montages or protocols, while others require many scalp electrodes. In this study, we propose a method based on the Multi-channel Wiener filter (MWF) to overcome those shortcomings. Nine children with unilateral CI and nine age-matched normal hearing children (control) participated in the study. EEG data were acquired on a relatively low number of electrodes (n = 16) during resting condition and during an auditory task. The obtained results obtained allowed to characterize CI artifact on the affected electrode and to significantly reduce, if not remove it through MWF filtering. Moreover, the results indicate, by comparing the two sample populations, that the EEG data loss is minimal in CI users after filtering, and that data maintain EEG physiological characteristics.
引用
收藏
页数:16
相关论文
共 50 条
  • [41] INCORPORATING RELATIVE TRANSFER FUNCTION PRESERVATION INTO THE BINAURAL MULTI-CHANNEL WIENER FILTER FOR HEARING AIDS
    Marquardt, Daniel
    Hadad, Elior
    Gannot, Sharon
    Doclo, Simon
    2016 IEEE INTERNATIONAL CONFERENCE ON ACOUSTICS, SPEECH AND SIGNAL PROCESSING PROCEEDINGS, 2016, : 6500 - 6504
  • [42] Improved speech enhancement of multi-channel Wiener filter using adjustment of principal subspace vector
    Kim, Gibak
    JOURNAL OF THE ACOUSTICAL SOCIETY OF KOREA, 2020, 39 (05): : 490 - 496
  • [43] Multi-channel Convolutional Neural Networks for Automatic Detection of Speech Deficits in Cochlear Implant Users
    Arias-Vergara, Tomas
    Vasquez-Correa, Juan Camilo
    Gollwitzer, Sandra
    Orozco-Arroyave, Juan Rafael
    Schuster, Maria
    Noeth, Elmar
    PROGRESS IN PATTERN RECOGNITION, IMAGE ANALYSIS, COMPUTER VISION, AND APPLICATIONS (CIARP 2019), 2019, 11896 : 679 - 687
  • [45] EFFICIENT COMPUTATION OF MICROPHONE UTILITY IN A WIRELESS ACOUSTIC SENSOR NETWORK WITH MULTI-CHANNEL WIENER FILTER BASED NOISE REDUCTION
    Szurley, Joseph
    Bertrand, Alexander
    Moonen, Marc
    2012 IEEE INTERNATIONAL CONFERENCE ON ACOUSTICS, SPEECH AND SIGNAL PROCESSING (ICASSP), 2012, : 2657 - 2660
  • [46] The multi-channel cochlear implant: Multi-disciplinary development of electrical stimulation of the cochlea and the resulting clinical benefit
    Clark, Graeme M.
    HEARING RESEARCH, 2015, 322 : 4 - 13
  • [47] SNOAR: a new regression approach for the removal of ocular artifact from multi-channel electroencephalogram signals
    Ruchi Juyal
    Hariharan Muthusamy
    Niraj Kumar
    Medical & Biological Engineering & Computing, 2022, 60 : 3567 - 3583
  • [48] SNOAR: a new regression approach for the removal of ocular artifact from multi-channel electroencephalogram signals
    Juyal, Ruchi
    Muthusamy, Hariharan
    Kumar, Niraj
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2022, 60 (12) : 3567 - 3583
  • [49] A comparison between overlap-save and weighted overlap-add filter banks for multi-channel Wiener filter based noise reduction
    Ruiz, Santiago
    Dietzen, Thomas
    van Waterschoot, Toon
    Moonen, Marc
    29TH EUROPEAN SIGNAL PROCESSING CONFERENCE (EUSIPCO 2021), 2021, : 336 - 340
  • [50] Study on Multi-Channel Receiver based on Polyphase Filter Bank
    Iwabuchi, Masashi
    Sakaguchi, Kei
    Araki, Kiyomichi
    ICSPCS: 2ND INTERNATIONAL CONFERENCE ON SIGNAL PROCESSING AND COMMUNICATION SYSTEMS, PROCEEDINGS, 2008, : 255 - 261