Characterization of Cochlear Implant Artifact and Removal Based on Multi-Channel Wiener Filter in Unilateral Child Patients

被引:0
|
作者
Rossi, Dario [1 ]
Cartocci, Giulia [1 ,2 ]
Inguscio, Bianca M. S. [1 ,2 ]
Capitolino, Giulia [3 ]
Borghini, Gianluca [1 ,2 ]
Di Flumeri, Gianluca [1 ,2 ]
Ronca, Vincenzo [2 ,3 ]
Giorgi, Andrea [4 ]
Vozzi, Alessia [2 ]
Capotorto, Rossella [4 ]
Babiloni, Fabio [2 ,5 ,6 ]
Scorpecci, Alessandro [7 ]
Giannantonio, Sara [7 ]
Marsella, Pasquale [7 ]
Leone, Carlo Antonio [8 ]
Grassia, Rosa [8 ]
Galletti, Francesco [9 ]
Ciodaro, Francesco [9 ]
Galletti, Cosimo [9 ]
Arico, Pietro [2 ,3 ]
机构
[1] Sapienza Univ Rome, Dept Mol Med, Viale Regina Elena 291, I-00161 Rome, Italy
[2] BrainSigns srl, Via Tirso 14, I-00198 Rome, Italy
[3] Sapienza Univ Rome, Dept Comp Control & Management Engn Antonio Rubert, Piazzale Aldo Moro 5, I-00185 Rome, Italy
[4] Sapienza Univ Rome, Dept Anat Histol Forens & Orthoped Sci, Piazzale Aldo Moro 5, I-00185 Rome, Italy
[5] Sapienza Univ Rome, Dept Physiol & Pharmacol Vittorio Erspamer, Piazzale Aldo Moro 5, I-00185 Rome, Italy
[6] Hangzhou Dianzi Univ, Dept Comp Sci, Hangzhou 310018, Peoples R China
[7] Bambino Gesu Pediat Hosp & Res Inst, Audiol & Otosurgery Unit, Piazza Sant Onofrio 4, I-00165 Rome, Italy
[8] Monaldi Hosp, Dept Otolaringol Head Neck Surg, Via Leonardo Bianchi, I-80131 Naples, Italy
[9] Univ Messina, Dept Otorhinolaryngol, Piazza Pugliatti 1, I-98122 Messina, Italy
来源
BIOENGINEERING-BASEL | 2024年 / 11卷 / 08期
关键词
EEG; cochlear implant; cochlear implant artifact; multi-channel Wiener filter (MWF); artifact reduction;
D O I
10.3390/bioengineering11080753
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
Cochlear implants (CI) allow deaf patients to improve language perception and improving their emotional valence assessment. Electroencephalographic (EEG) measures were employed so far to improve CI programming reliability and to evaluate listening effort in auditory tasks, which are particularly useful in conditions when subjective evaluations are scarcely appliable or reliable. Unfortunately, the presence of CI on the scalp introduces an electrical artifact coupled to EEG signals that masks physiological features recorded by electrodes close to the site of implant. Currently, methods for CI artifact removal have been developed for very specific EEG montages or protocols, while others require many scalp electrodes. In this study, we propose a method based on the Multi-channel Wiener filter (MWF) to overcome those shortcomings. Nine children with unilateral CI and nine age-matched normal hearing children (control) participated in the study. EEG data were acquired on a relatively low number of electrodes (n = 16) during resting condition and during an auditory task. The obtained results obtained allowed to characterize CI artifact on the affected electrode and to significantly reduce, if not remove it through MWF filtering. Moreover, the results indicate, by comparing the two sample populations, that the EEG data loss is minimal in CI users after filtering, and that data maintain EEG physiological characteristics.
引用
收藏
页数:16
相关论文
共 50 条
  • [21] Multi-channel thin film piezoelectric acoustic transducer for cochlear implant applications
    Yuksel, Muhammed Berat
    Ilik, Bedirhan
    Koyuncuoglu, Aziz
    Kulah, Haluk
    2019 IEEE SENSORS, 2019,
  • [22] Principal subspace modification for multi-channel Wiener filter in multi-microphone noise reduction
    Kim, Gibak
    Cho, Nam Ik
    2008 IEEE INTERNATIONAL CONFERENCE ON ACOUSTICS, SPEECH AND SIGNAL PROCESSING, VOLS 1-12, 2008, : 4909 - +
  • [23] Mixed noise removal filter for multi-channel images based on halfspace deepest location
    Baljozovic, Djordje
    Kovacevic, Branko
    Baljozovic, Aleksandra
    IET IMAGE PROCESSING, 2013, 7 (04) : 310 - 323
  • [24] Effectiveness of multi-channel unilateral cochlear implants for profoundly deaf children: a systematic review
    Bond, M.
    Elston, J.
    Mealing, S.
    Anderson, R.
    Weiner, G.
    Taylor, R. S.
    Liu, Z.
    Stein, K.
    CLINICAL OTOLARYNGOLOGY, 2009, 34 (03) : 199 - 211
  • [25] A FLEXIBLE SPEECH DISTORTIONWEIGHTED MULTI-CHANNEL WIENER FILTER FOR NOISE REDUCTION IN HEARING AIDS
    Ngo, Kim
    Moonen, Marc
    Jensen, Soren Holdt
    Wouters, Jan
    2011 IEEE INTERNATIONAL CONFERENCE ON ACOUSTICS, SPEECH, AND SIGNAL PROCESSING, 2011, : 2528 - 2531
  • [26] Multi-channel Wiener Filter for Speech Dereverberation in Hearing Aids - Sensitivity to DoA Errors
    Kuklasinski, Adam
    Doclo, Simon
    Jensen, Soren H.
    Jensen, Jesper
    60TH AES INTERNATIONAL CONFERENCE ON DREAMS (DEREVERBERATION AND REVERBERATION OF AUDIO, MUSIC, AND SPEECH), 2016,
  • [27] Speech distortion weighted multi-channel Wiener filter and its application to speech recognition
    Kim, Gibak
    IEICE ELECTRONICS EXPRESS, 2015, 12 (06): : 1 - 7
  • [28] A new face recognition method for blurred images using multi-channel Wiener filter
    Wang, Ching-Te
    Chen, Tung-Shou
    Liao, Chiu-Hsiung
    Chang, Feng-Yung
    IMECS 2006: INTERNATIONAL MULTICONFERENCE OF ENGINEERS AND COMPUTER SCIENTISTS, 2006, : 519 - +
  • [29] EEG SIGNAL ENHANCEMENT USING MULTI-CHANNEL WIENER FILTER WITH A SPATIAL CORRELATION PRIOR
    Maki, Hayato
    Toda, Tomoki
    Sakti, Sakriani
    Neubig, Graham
    Nakamura, Satoshi
    2015 IEEE INTERNATIONAL CONFERENCE ON ACOUSTICS, SPEECH, AND SIGNAL PROCESSING (ICASSP), 2015, : 2639 - 2643
  • [30] Wiener filter applied with a multi-channel method for EBT2 film dosimetry
    Chang, Liyun