Characterization of Cochlear Implant Artifact and Removal Based on Multi-Channel Wiener Filter in Unilateral Child Patients

被引:0
|
作者
Rossi, Dario [1 ]
Cartocci, Giulia [1 ,2 ]
Inguscio, Bianca M. S. [1 ,2 ]
Capitolino, Giulia [3 ]
Borghini, Gianluca [1 ,2 ]
Di Flumeri, Gianluca [1 ,2 ]
Ronca, Vincenzo [2 ,3 ]
Giorgi, Andrea [4 ]
Vozzi, Alessia [2 ]
Capotorto, Rossella [4 ]
Babiloni, Fabio [2 ,5 ,6 ]
Scorpecci, Alessandro [7 ]
Giannantonio, Sara [7 ]
Marsella, Pasquale [7 ]
Leone, Carlo Antonio [8 ]
Grassia, Rosa [8 ]
Galletti, Francesco [9 ]
Ciodaro, Francesco [9 ]
Galletti, Cosimo [9 ]
Arico, Pietro [2 ,3 ]
机构
[1] Sapienza Univ Rome, Dept Mol Med, Viale Regina Elena 291, I-00161 Rome, Italy
[2] BrainSigns srl, Via Tirso 14, I-00198 Rome, Italy
[3] Sapienza Univ Rome, Dept Comp Control & Management Engn Antonio Rubert, Piazzale Aldo Moro 5, I-00185 Rome, Italy
[4] Sapienza Univ Rome, Dept Anat Histol Forens & Orthoped Sci, Piazzale Aldo Moro 5, I-00185 Rome, Italy
[5] Sapienza Univ Rome, Dept Physiol & Pharmacol Vittorio Erspamer, Piazzale Aldo Moro 5, I-00185 Rome, Italy
[6] Hangzhou Dianzi Univ, Dept Comp Sci, Hangzhou 310018, Peoples R China
[7] Bambino Gesu Pediat Hosp & Res Inst, Audiol & Otosurgery Unit, Piazza Sant Onofrio 4, I-00165 Rome, Italy
[8] Monaldi Hosp, Dept Otolaringol Head Neck Surg, Via Leonardo Bianchi, I-80131 Naples, Italy
[9] Univ Messina, Dept Otorhinolaryngol, Piazza Pugliatti 1, I-98122 Messina, Italy
来源
BIOENGINEERING-BASEL | 2024年 / 11卷 / 08期
关键词
EEG; cochlear implant; cochlear implant artifact; multi-channel Wiener filter (MWF); artifact reduction;
D O I
10.3390/bioengineering11080753
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
Cochlear implants (CI) allow deaf patients to improve language perception and improving their emotional valence assessment. Electroencephalographic (EEG) measures were employed so far to improve CI programming reliability and to evaluate listening effort in auditory tasks, which are particularly useful in conditions when subjective evaluations are scarcely appliable or reliable. Unfortunately, the presence of CI on the scalp introduces an electrical artifact coupled to EEG signals that masks physiological features recorded by electrodes close to the site of implant. Currently, methods for CI artifact removal have been developed for very specific EEG montages or protocols, while others require many scalp electrodes. In this study, we propose a method based on the Multi-channel Wiener filter (MWF) to overcome those shortcomings. Nine children with unilateral CI and nine age-matched normal hearing children (control) participated in the study. EEG data were acquired on a relatively low number of electrodes (n = 16) during resting condition and during an auditory task. The obtained results obtained allowed to characterize CI artifact on the affected electrode and to significantly reduce, if not remove it through MWF filtering. Moreover, the results indicate, by comparing the two sample populations, that the EEG data loss is minimal in CI users after filtering, and that data maintain EEG physiological characteristics.
引用
收藏
页数:16
相关论文
共 50 条
  • [1] A generic EEG artifact removal algorithm based on the multi-channel Wiener filter
    Somers, Ben
    Francart, Tom
    Bertrand, Alexander
    JOURNAL OF NEURAL ENGINEERING, 2018, 15 (03)
  • [2] An Evaluation of EEG Ocular Artifact Removal with a Multi-channel Wiener Filter Based on Probabilistic Generative Model
    Maki, Hayato
    Toda, Tomoki
    Sakti, Sakriani
    Neubig, Graham
    Nakamura, Satoshi
    2015 37TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2015, : 2775 - 2778
  • [3] Multi-channel Iterative Dereverberation based on Codebook Constrained Iterative Multi-channel Wiener Filter
    Ajay, S.
    Sreenivas, T. V.
    11TH ANNUAL CONFERENCE OF THE INTERNATIONAL SPEECH COMMUNICATION ASSOCIATION 2010 (INTERSPEECH 2010), VOLS 1-2, 2010, : 981 - 984
  • [4] The application and computer simulation of multi-channel cochlear implant based on all phase DFT filter
    Tian, Lan
    Hou, Zhengxin
    Pang, Zhimin
    2007 IEEE INTERNATIONAL CONFERENCE ON ACOUSTICS, SPEECH, AND SIGNAL PROCESSING, VOL IV, PTS 1-3, 2007, : 701 - +
  • [5] A multi-mode and multi-channel cochlear implant
    Zhang, C
    Wang, ZH
    Li, DM
    Dong, M
    2004 7TH INTERNATIONAL CONFERENCE ON SIGNAL PROCESSING PROCEEDINGS, VOLS 1-3, 2004, : 2237 - 2240
  • [6] Exploiting Multi-Channel Speech Presence Probability in Parametric Multi-Channel Wiener Filter
    Bagheri, Saeed
    Giacobello, Daniele
    INTERSPEECH 2019, 2019, : 101 - 105
  • [7] Blind wiener filter estimation for multi-channel systems based on partial information
    Ding, Z
    1997 IEEE INTERNATIONAL CONFERENCE ON ACOUSTICS, SPEECH, AND SIGNAL PROCESSING, VOLS I - V: VOL I: PLENARY, EXPERT SUMMARIES, SPECIAL, AUDIO, UNDERWATER ACOUSTICS, VLSI; VOL II: SPEECH PROCESSING; VOL III: SPEECH PROCESSING, DIGITAL SIGNAL PROCESSING; VOL IV: MULTIDIMENSIONAL SIGNAL PROCESSING, NEURAL NETWORKS - VOL V: STATISTICAL SIGNAL AND ARRAY PROCESSING, APPLICATIONS, 1997, : 3609 - 3612
  • [8] IOWA COCHLEAR IMPLANT CLINICAL PROJECT - RESULTS WITH 2 SINGLE-CHANNEL COCHLEAR IMPLANTS AND ONE MULTI-CHANNEL COCHLEAR IMPLANT
    GANTZ, BJ
    TYLER, RS
    PREECE, J
    MCCABE, BF
    LOWDER, MW
    OTTO, SR
    LARYNGOSCOPE, 1985, 95 (04): : 443 - 449
  • [9] Multi-channel SAR ground moving target detection based on multistage Wiener filter
    Tian B.
    Zhu D.-Y.
    Wu D.
    Zhu Z.-D.
    Dianzi Yu Xinxi Xuebao/Journal of Electronics and Information Technology, 2011, 33 (10): : 2420 - 2426
  • [10] DSP Integration of Sound Source Localization and Multi-channel Wiener Filter
    Lee, Byoung-gi
    Kim, Hyun-dong
    Choi, Jong-suk
    Kim, Seyun
    Cho, Nam Ik
    2010 IEEE INTERNATIONAL CONFERENCE ON ROBOTICS AND AUTOMATION (ICRA), 2010, : 4830 - 4835