Radiation dose analysis in interventional neuroradiology of unruptured aneurysm cases

被引:0
|
作者
Kawauchi, Satoru [1 ,2 ,3 ]
Chida, Koichi [2 ]
Moritake, Takashi [4 ]
Hamada, Yusuke [1 ]
Tsuruta, Wataro [5 ]
机构
[1] Toranomon Gen Hosp, Dept Radiol, 2-2-2 Toranomon,Minato ku, Tokyo 1058470, Japan
[2] Tohoku Univ, Grad Sch Med, Course Radiol Technol, Hlth Sci, 2-1 Seiryo,Aoba ku, Sendai, Miyagi 9808575, Japan
[3] Okinaka Mem Inst Med Res, 2-2-2 Toranomon,Minato ku, Tokyo 1058470, Japan
[4] Natl Inst Radiol Sci, Natl Inst Quantum Sci & Technol, Dept Radiat Regulatory Sci Res, 4-9-1 Anagawa,Inage ku, Chiba 2638555, Japan
[5] Toranomon Gen Hosp, Dept Endovasc Neurosurg, 2-2-2 Toranomon,Minato ku, Tokyo 1058470, Japan
基金
日本学术振兴会;
关键词
peak skin dose; lens dose; neurointerventional radiology; unruptured aneurysm; radiophotoluminescent glass dosimeter; BEAM COMPUTED-TOMOGRAPHY; PIPELINE EMBOLIZATION DEVICE; STENT-ASSISTED COILING; X-RAY; FLOW DIVERSION; PATIENT; TIME; FLUOROSCOPY; PERFORMANCE; REDUCTION;
D O I
10.1088/1361-6498/ad76b3
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
This study aimed to evaluate the radiation doses (peak skin dose (PSD) and bilateral lens dose) for each interventional neuroradiology procedure. A direct measurement system consisting of small radiophotoluminescence glass dosimeter chips and a dosimetry cap made of thin stretchable polyester was used for radiation dosimetry. The mean PSDs for each procedure were 1565 +/- 590 mGy (simple technique coil embolization (STCE) cases), 1851 +/- 825 mGy (balloon-assisted coil embolization (BACE) cases), 2583 +/- 967 mGy (stent-assisted coil embolization (SACE) cases), 1690 +/- 597 mGy (simple flow-diverter stenting (FDS) cases), and 2214 +/- 726 mGy (FDS + coiling cases). The mean PSD was higher in SACE cases than in STCE, BACE, and simple FDS cases. Moreover, the PSD exceeded 2000 mGy and 3000 mGy in 46 (67.6%) and 19 (27.9%) SACE cases, respectively. The left lens doses for each procedure were 126 +/- 111 mGy (STCE cases), 163 +/- 152 mGy (BACE cases), 184 +/- 148 mGy (SACE cases), 144 +/- 60 mGy (simple FDS cases), and 242 +/- 178 mGy (FDS + coiling cases). The left lens dose in SACE cases was higher than that in STCE cases and exceeded 500 mGy in 3 (4.4%) patients. In FDS + coiling cases, the mean PSD and left lens dose were 2214 +/- 726 mGy and 242 +/- 178 mGy, respectively. The left lens dose was higher than that in the STCE and BACE cases, with two (15.4%) patients receiving doses >500 mGy in FDS + coiling cases. The detailed data obtained in this study are expected to contribute to the promotion of radiation dose optimization.
引用
收藏
页数:10
相关论文
共 50 条
  • [41] Rare Cases of Bronchial Aneurysm and Comparison of Interventional Embolization in the Treatment of True Bronchial Aneurysm and Pseudobronchial Aneurysm
    Lin, Jia-Li
    Ji, Yuan-Yuan
    Zhang, Ming-Zhe
    Tang, Yi
    Wang, Ruo-Li
    Ruan, Dan-Dan
    Zhou, Yan-Feng
    Wu, Shao-Jie
    Cai, Sen-Lin
    Zhang, Jian-Hui
    Meng, Xiao-Rong
    Luo, Jie-Wei
    Fang, Zhu-Ting
    [J]. FRONTIERS IN CARDIOVASCULAR MEDICINE, 2022, 9
  • [42] MONITORING AND REDUCTION OF PATIENT AND STAFF RADIATION EXPOSURE DURING INTERVENTIONAL AND THERAPEUTIC NEURORADIOLOGY PROCEDURES
    KUAN, HM
    MANZIONE, JV
    FERRETTI, JA
    [J]. RADIOLOGY, 1995, 197 : 359 - 359
  • [43] Radiation dose in cerebral angiography and flat detector CT applications in neuroradiology
    Struffert, T.
    Lang, S.
    Scholz, R.
    Hauer, M.
    Doerfler, A.
    [J]. RADIOLOGE, 2015, 55 (08): : 654 - 661
  • [44] Radiation Dose From Cone-Beam CT in Neuroradiology Applications
    Berris, Theocharis
    Gupta, Rajiv
    Rehani, Madan M.
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2013, 200 (04) : 755 - 761
  • [45] Patient dose during interventional neuroradiology procedures: Results from a multi-center study
    Kien, N.
    Rehel, J. -L.
    Etard, C.
    Aubert, B.
    [J]. JOURNAL DE RADIOLOGIE, 2011, 92 (12): : 1101 - 1112
  • [46] Hemodynamic Characteristic Analysis of Aneurysm Wall Enhancement in Unruptured Middle Cerebral Artery Aneurysm
    Zhong, Weiying
    Du, Yiming
    Kuang, Hong
    Liu, Ming
    Xue, Feng
    Bai, Xue
    Wang, Donghai
    Su, Wandong
    Wang, Yunyan
    [J]. FRONTIERS IN NEUROLOGY, 2022, 13
  • [47] RADIATION-DOSE TO CRITICAL ORGANS OF STAFF AND PATIENTS DURING NEURORADIOLOGY
    HEATON, B
    MILLARD, S
    [J]. BRITISH JOURNAL OF RADIOLOGY, 1979, 52 (623): : 888 - 892
  • [48] A study of the relationship between peak skin dose and cumulative air kerma in interventional neuroradiology and cardiology
    Neil, S.
    Padgham, C.
    Martin, C. J.
    [J]. JOURNAL OF RADIOLOGICAL PROTECTION, 2010, 30 (04) : 659 - 672
  • [49] Directly Measuring Peak Skin Dose During Fluoroscopically-Guided Neuroradiology Interventional Surgeries
    Quails, N.
    Laurent, D.
    Corliss, B.
    Hoh, B.
    Polifka, A.
    Fox, W.
    Rill, L.
    Arreola, M.
    [J]. MEDICAL PHYSICS, 2020, 47 (06) : E528 - E528
  • [50] Treatment of Unruptured Cerebral Artery Aneurysm: A Meta-Analysis
    Turkistani, Fatema
    Bin Sawad, Aseel
    [J]. INTERNATIONAL JOURNAL OF LIFE SCIENCE AND PHARMA RESEARCH, 2021, 11 (05): : 61 - 80