Radiation dose analysis in interventional neuroradiology of unruptured aneurysm cases

被引:0
|
作者
Kawauchi, Satoru [1 ,2 ,3 ]
Chida, Koichi [2 ]
Moritake, Takashi [4 ]
Hamada, Yusuke [1 ]
Tsuruta, Wataro [5 ]
机构
[1] Toranomon Gen Hosp, Dept Radiol, 2-2-2 Toranomon,Minato ku, Tokyo 1058470, Japan
[2] Tohoku Univ, Grad Sch Med, Course Radiol Technol, Hlth Sci, 2-1 Seiryo,Aoba ku, Sendai, Miyagi 9808575, Japan
[3] Okinaka Mem Inst Med Res, 2-2-2 Toranomon,Minato ku, Tokyo 1058470, Japan
[4] Natl Inst Radiol Sci, Natl Inst Quantum Sci & Technol, Dept Radiat Regulatory Sci Res, 4-9-1 Anagawa,Inage ku, Chiba 2638555, Japan
[5] Toranomon Gen Hosp, Dept Endovasc Neurosurg, 2-2-2 Toranomon,Minato ku, Tokyo 1058470, Japan
基金
日本学术振兴会;
关键词
peak skin dose; lens dose; neurointerventional radiology; unruptured aneurysm; radiophotoluminescent glass dosimeter; BEAM COMPUTED-TOMOGRAPHY; PIPELINE EMBOLIZATION DEVICE; STENT-ASSISTED COILING; X-RAY; FLOW DIVERSION; PATIENT; TIME; FLUOROSCOPY; PERFORMANCE; REDUCTION;
D O I
10.1088/1361-6498/ad76b3
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
This study aimed to evaluate the radiation doses (peak skin dose (PSD) and bilateral lens dose) for each interventional neuroradiology procedure. A direct measurement system consisting of small radiophotoluminescence glass dosimeter chips and a dosimetry cap made of thin stretchable polyester was used for radiation dosimetry. The mean PSDs for each procedure were 1565 +/- 590 mGy (simple technique coil embolization (STCE) cases), 1851 +/- 825 mGy (balloon-assisted coil embolization (BACE) cases), 2583 +/- 967 mGy (stent-assisted coil embolization (SACE) cases), 1690 +/- 597 mGy (simple flow-diverter stenting (FDS) cases), and 2214 +/- 726 mGy (FDS + coiling cases). The mean PSD was higher in SACE cases than in STCE, BACE, and simple FDS cases. Moreover, the PSD exceeded 2000 mGy and 3000 mGy in 46 (67.6%) and 19 (27.9%) SACE cases, respectively. The left lens doses for each procedure were 126 +/- 111 mGy (STCE cases), 163 +/- 152 mGy (BACE cases), 184 +/- 148 mGy (SACE cases), 144 +/- 60 mGy (simple FDS cases), and 242 +/- 178 mGy (FDS + coiling cases). The left lens dose in SACE cases was higher than that in STCE cases and exceeded 500 mGy in 3 (4.4%) patients. In FDS + coiling cases, the mean PSD and left lens dose were 2214 +/- 726 mGy and 242 +/- 178 mGy, respectively. The left lens dose was higher than that in the STCE and BACE cases, with two (15.4%) patients receiving doses >500 mGy in FDS + coiling cases. The detailed data obtained in this study are expected to contribute to the promotion of radiation dose optimization.
引用
收藏
页数:10
相关论文
共 50 条
  • [21] Analysis of Malpractice Claims Involving Diagnostic and Interventional Neuroradiology
    Deckey, David G.
    Eltorai, Adam E. M.
    Findal, Gaurav
    Daniels, Alan H.
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF RADIOLOGY, 2019, 16 (05) : 764 - 769
  • [22] SURGICAL PROGNOSIS OF UNRUPTURED INTRACRANIAL SURGICAL ANEURYSM 50 CASES
    JOMIN, M
    LESOIN, F
    LOZES, G
    FAVAZ, A
    VILLETTE, L
    AUTRICQUE, A
    [J]. PRESSE MEDICALE, 1987, 16 (08): : 375 - 377
  • [23] Update on radiation safety and dose reduction in pediatric neuroradiology
    Mahadevappa Mahesh
    [J]. Pediatric Radiology, 2015, 45 : 370 - 374
  • [24] Update on radiation safety and dose reduction in pediatric neuroradiology
    Mahesh, Mahadevappa
    [J]. PEDIATRIC RADIOLOGY, 2015, 45 : 370 - 374
  • [25] A method for a real time estimation of entrance skin dose distribution in interventional neuroradiology
    Rampado, O
    Ropolo, R
    [J]. MEDICAL PHYSICS, 2004, 31 (08) : 2356 - 2361
  • [26] Surgeon eye lens dose monitoring in interventional neuroradiology, cardiovascular and radiology procedures
    Busoni, S.
    Bruzzi, M.
    Giomi, S.
    Poggiali, C.
    Quattrocchi, M.
    Betti, M.
    D'Urso, D.
    Fedeli, L.
    Mazzoni, L. N.
    Paolucci, M.
    Rossi, F.
    Taddeucci, A.
    Bettarini, S.
    Tortoli, P.
    Belli, G.
    Bernardi, L.
    Gasperi, C.
    Campanella, F.
    [J]. PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2022, 104 : 123 - 128
  • [27] Radiation dose in interventional fluoroscopic procedures
    Geise, RA
    O'Dea, TJ
    [J]. APPLIED RADIATION AND ISOTOPES, 1999, 50 (01) : 173 - 184
  • [28] Incidence and neurological outcomes of aneurysm rupture during interventional neuroradiology procedures in a hybrid operating suite
    Yamakawa, Kentaro
    Kiyama, Shuya
    Murayama, Yuichi
    Uezono, Shoichi
    [J]. JOURNAL OF ANESTHESIA, 2012, 26 (04) : 592 - 594
  • [29] Incidence and neurological outcomes of aneurysm rupture during interventional neuroradiology procedures in a hybrid operating suite
    Kentaro Yamakawa
    Shuya Kiyama
    Yuichi Murayama
    Shoichi Uezono
    [J]. Journal of Anesthesia, 2012, 26 : 592 - 594
  • [30] Radiation dose-reduction strategies for neuroradiology CT protocols
    Smith, A. B.
    Dillon, W. P.
    Gould, R.
    Wintermark, M.
    [J]. AMERICAN JOURNAL OF NEURORADIOLOGY, 2007, 28 (09) : 1628 - 1632