Radiation dose analysis in interventional neuroradiology of unruptured aneurysm cases

被引:0
|
作者
Kawauchi, Satoru [1 ,2 ,3 ]
Chida, Koichi [2 ]
Moritake, Takashi [4 ]
Hamada, Yusuke [1 ]
Tsuruta, Wataro [5 ]
机构
[1] Toranomon Gen Hosp, Dept Radiol, 2-2-2 Toranomon,Minato ku, Tokyo 1058470, Japan
[2] Tohoku Univ, Grad Sch Med, Course Radiol Technol, Hlth Sci, 2-1 Seiryo,Aoba ku, Sendai, Miyagi 9808575, Japan
[3] Okinaka Mem Inst Med Res, 2-2-2 Toranomon,Minato ku, Tokyo 1058470, Japan
[4] Natl Inst Radiol Sci, Natl Inst Quantum Sci & Technol, Dept Radiat Regulatory Sci Res, 4-9-1 Anagawa,Inage ku, Chiba 2638555, Japan
[5] Toranomon Gen Hosp, Dept Endovasc Neurosurg, 2-2-2 Toranomon,Minato ku, Tokyo 1058470, Japan
基金
日本学术振兴会;
关键词
peak skin dose; lens dose; neurointerventional radiology; unruptured aneurysm; radiophotoluminescent glass dosimeter; BEAM COMPUTED-TOMOGRAPHY; PIPELINE EMBOLIZATION DEVICE; STENT-ASSISTED COILING; X-RAY; FLOW DIVERSION; PATIENT; TIME; FLUOROSCOPY; PERFORMANCE; REDUCTION;
D O I
10.1088/1361-6498/ad76b3
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
This study aimed to evaluate the radiation doses (peak skin dose (PSD) and bilateral lens dose) for each interventional neuroradiology procedure. A direct measurement system consisting of small radiophotoluminescence glass dosimeter chips and a dosimetry cap made of thin stretchable polyester was used for radiation dosimetry. The mean PSDs for each procedure were 1565 +/- 590 mGy (simple technique coil embolization (STCE) cases), 1851 +/- 825 mGy (balloon-assisted coil embolization (BACE) cases), 2583 +/- 967 mGy (stent-assisted coil embolization (SACE) cases), 1690 +/- 597 mGy (simple flow-diverter stenting (FDS) cases), and 2214 +/- 726 mGy (FDS + coiling cases). The mean PSD was higher in SACE cases than in STCE, BACE, and simple FDS cases. Moreover, the PSD exceeded 2000 mGy and 3000 mGy in 46 (67.6%) and 19 (27.9%) SACE cases, respectively. The left lens doses for each procedure were 126 +/- 111 mGy (STCE cases), 163 +/- 152 mGy (BACE cases), 184 +/- 148 mGy (SACE cases), 144 +/- 60 mGy (simple FDS cases), and 242 +/- 178 mGy (FDS + coiling cases). The left lens dose in SACE cases was higher than that in STCE cases and exceeded 500 mGy in 3 (4.4%) patients. In FDS + coiling cases, the mean PSD and left lens dose were 2214 +/- 726 mGy and 242 +/- 178 mGy, respectively. The left lens dose was higher than that in the STCE and BACE cases, with two (15.4%) patients receiving doses >500 mGy in FDS + coiling cases. The detailed data obtained in this study are expected to contribute to the promotion of radiation dose optimization.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] Radiation Dose Measurement with Newly Developed Head Phantom for Interventional Neuroradiology
    Abe, T.
    Uchiyama, Y.
    Tanaka, N.
    Hayabuchi, N.
    [J]. NEURORADIOLOGY JOURNAL, 2011, 24 (05): : 813 - 815
  • [2] Effective Dose and Thyroid Dose in Interventional Neuroradiology
    Magill, D.
    [J]. MEDICAL PHYSICS, 2011, 38 (06)
  • [3] ANEURYSM OF THE VEIN OF GALEN SUCCESSFULLY TREATED BY INTERVENTIONAL NEURORADIOLOGY
    QURTOM, HA
    QURTOM, MA
    BALASUNDARAM, P
    ELSALEH, EA
    KENDALL, B
    [J]. ANNALS OF SAUDI MEDICINE, 1992, 12 (02) : 206 - 208
  • [4] Radiation dose and cancer risk among pediatric patients undergoing interventional neuroradiology procedures
    Thierry-Chef, Isabelle
    Simon, Steven L.
    Miller, Donald L.
    [J]. PEDIATRIC RADIOLOGY, 2006, 36 (Suppl 2) : 159 - 162
  • [5] Radiation dose and cancer risk among pediatric patients undergoing interventional neuroradiology procedures
    Isabelle Thierry-Chef
    Steven L. Simon
    Donald L. Miller
    [J]. Pediatric Radiology, 2006, 36 : 159 - 162
  • [6] Scalp dose in interventional neuroradiology: an assessment of MOSFET dosimetry
    Guersen, J.
    Mechin, G.
    Chassin, V.
    Gabrillargues, J.
    Jean, B.
    Chabert, E.
    Pereira, B.
    Boyer, L.
    Magnier, F.
    Cassagnes, L.
    [J]. RADIOPROTECTION, 2018, 53 (02) : 133 - 138
  • [7] Interventional Neuroradiology Cases With Intraprocedural Clots: Initial Experience
    Gloss, David S.
    Alkire, Brian W.
    [J]. JOURNAL OF CLINICAL NEUROPHYSIOLOGY, 2014, 31 (03) : 229 - 231
  • [8] Brain Radiation Doses to Patients in an Interventional Neuroradiology Laboratory
    Sanchez, R. M.
    Vano, E.
    Fernandez, J. M.
    Moreu, M.
    Lopez-Ibor, L.
    [J]. AMERICAN JOURNAL OF NEURORADIOLOGY, 2014, 35 (07) : 1276 - 1280
  • [9] Absorbed dose and deterministic effects to patients from interventional neuroradiology
    Mooney, RB
    McKinstry, CS
    Kamel, HAM
    [J]. BRITISH JOURNAL OF RADIOLOGY, 2000, 73 (871): : 745 - 751
  • [10] Association of radiation-induced epilation and interventional neuroradiology procedures
    Carrick, Deborah
    do Nascimento, Vinicius Carraro
    [J]. JOURNAL OF MEDICAL IMAGING AND RADIATION ONCOLOGY, 2024,