Analysis of near-infrared autofluorescence imaging for detection of inadvertently resected parathyroid glands after endoscopic thyroidectomy

被引:0
|
作者
Kuo, Ting-Chun [1 ]
Chen, Kuen-Yuan [1 ]
Lai, Chieh-Wen [2 ]
Lin, Ming-Tsan [1 ]
Chang, Chin-Hao [3 ,4 ]
Wu, Ming-Hsun [1 ]
机构
[1] Natl Taiwan Univ Hosp, Dept Surg, 7 Chung Shan S Rd, Taipei 10002, Taiwan
[2] Tzu Chi Univ, Sch Med, Hualien, Taiwan
[3] Natl Taiwan Univ Hosp, Dept Med Res, Taipei, Taiwan
[4] Natl Taiwan Univ, Taipei, Taiwan
来源
EJSO | 2024年 / 50卷 / 11期
关键词
Near-infrared autofluorescence (NIRAF); Autofluorescence (AF); Parathyroid gland (PTG); Inadvertently resected parathyroid glands; Endoscopic thyroidectomy; IDENTIFICATION; FLUORESCENCE;
D O I
10.1016/j.ejso.2024.108648
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background: Preserving parathyroid function during thyroidectomy is crucial, but remains challenging. Real-time near-infrared autofluorescence (NIRAF) aids surgeons in intraoperative parathyroid gland (PTG) identification. However, its role in detecting PTGs unintentionally removed during surgery is unclear. Study design: This prospective study included adult patients undergoing endoscopic thyroidectomy. Surgeons identified and documented PTGs visually. Excised specimens underwent visual inspection and NIRAF imaging (PDE-Neo II). All fluorescent tissues were dissected and pathologically evaluated (reference standard). One scanned image per lobe was chosen to quantify autofluorescence (AF) intensity. Results: Overall, 95 patients underwent endoscopic thyroidectomies, with NIRAF imaging applied to 152 excised lobes. Of these, 19 lobes displayed a total of 23 spots with increased intensity. 175 specimens were sent for pathological evaluation, and 7 were confirmed to be parathyroid tissue. NIRAF demonstrated 100.0 % sensitivity and 90.5 % specificity for predicting parathyroid tissue, with 30.4 % positive predictive value, 100.0 % negative predictive value of and 90.9 % accuracy. Quantitatively normalized, the AF signal intensity was significantly higher in NIRAF-positive tissues than negative (4.3 vs 1.2 times, p < 0.0001). Additionally, the AF signal intensity in regions pathologically confirmed of parathyroid tissue was higher than non-parathyroid tissue (9.1 vs 2.1 times, p < 0.0001). Conclusion: This study suggests that NIRAF has high sensitivity and specificity for detecting inadvertently resected PTGs after endoscopic thyroidectomy, contributing to preservation efforts. However, NIRAF-positive tissues still require additional confirmation through multiple methods, emphasizing other examinations to verify that they are indeed parathyroid tissues. Further research is warranted to refine NIRAF imaging parameters.
引用
收藏
页数:7
相关论文
共 50 条
  • [31] Investigation of near-infrared autofluorescence imaging for the detection of breast cancer
    Demos, SG
    Bold, R
    White, RD
    Ramsamooj, R
    IEEE JOURNAL OF SELECTED TOPICS IN QUANTUM ELECTRONICS, 2005, 11 (04) : 791 - 798
  • [32] Can near-infrared autofluorescence imaging be used for intraoperative confirmation of parathyroid tissue?
    Berber, Eren
    Akbulut, Serkan
    JOURNAL OF SURGICAL ONCOLOGY, 2021, 124 (07) : 1008 - 1013
  • [33] Label-free Intraoperative Parathyroid Localization With Near-Infrared Autofluorescence Imaging
    McWade, Melanie A.
    Paras, Constantine
    White, Lisa M.
    Phay, John E.
    Solorzano, Carmen C.
    Broome, James T.
    Mahadevan-Jansen, Anita
    JOURNAL OF CLINICAL ENDOCRINOLOGY & METABOLISM, 2014, 99 (12): : 4574 - 4580
  • [34] Near-infrared fluorescent imaging techniques for the detection and preservation of parathyroid glands during endocrine surgery
    Demarchi, Marco Stefano
    Karenovics, Wolfram
    Bedat, Benoit
    Triponez, Frederic
    INNOVATIVE SURGICAL SCIENCES, 2022, 7 (3-4): : 87 - 98
  • [35] Intraoperative near-infrared autofluorescence imaging for hypocalcemia risk reduction after total thyroidectomy: Evidence from a meta-analysis
    Weng, Yu-jing
    Jiang, Jiang
    Min, Lei
    Ai, Qing
    Chen, De-biao
    Chen, Wei-chun
    Huang, Zhi-heng
    HEAD AND NECK-JOURNAL FOR THE SCIENCES AND SPECIALTIES OF THE HEAD AND NECK, 2021, 43 (08): : 2523 - 2533
  • [36] Near-Infrared Autofluorescence Signature: A New Parameter for Intraoperative Assessment of Parathyroid Glands in Primary Hyperparathyroidism
    Akgun, Ege
    Ibrahimli, Arturan
    Berber, Eren
    JOURNAL OF THE AMERICAN COLLEGE OF SURGEONS, 2025, 240 (01) : 84 - 93
  • [37] Use of Near-Infrared Autofluorescence Imaging During Thyroidectomy Associated with Improved Clinical Outcomes
    Guo, Feiyue
    Xu, Lei
    Zhang, Jing
    INDIAN JOURNAL OF SURGERY, 2022, 86 (Suppl 1) : 10 - 17
  • [38] Intraoperative verification of parathyroid glands in primary and secondary hyperparathyroidism using near-infrared autofluorescence (IOPA)
    Wolf, Henning W.
    Grumbeck, Bernhard
    Runkel, Norbert
    UPDATES IN SURGERY, 2019, 71 (03) : 579 - 585
  • [39] Near-Infrared Autofluorescence Identification of Ectopic Parathyroid Lesions
    Abe, Kanako
    Takahashi, Takeshi
    Yokoyama, Yusuke
    Shodo, Ryusuke
    Ueki, Yushi
    Yamazaki, Keisuke
    Horii, Arata
    LARYNGOSCOPE, 2024, 134 (01): : 496 - 500
  • [40] Correlation Between Near-Infrared Autofluorescence Properties and Sestamibi Uptakes of Parathyroid Glands in Primary Hyperparathyroidism
    Akgun, Ege
    Ibrahimli, Arturan
    Rahman, Mobeen
    Griffith, Christopher
    Berber, Eren
    OTOLARYNGOLOGY-HEAD AND NECK SURGERY, 2024, 171 (05) : 1341 - 1348