Effective Radiation Dose from Cone-Beam Computed Tomography Guidance during Bronchoscopic Tumour Ablation

被引:0
|
作者
Watson, Jack Mitchell [1 ]
Einsiedel, Paul F. [2 ]
Antippa, Phillip [4 ]
Rangamuwa, Kanishka [1 ]
Irving, Louis [1 ]
Steinfort, Daniel P. [1 ,3 ,5 ]
机构
[1] Royal Melbourne Hosp, Dept Resp & Sleep Med, Melbourne, Vic, Australia
[2] Royal Melbourne Hosp, Dept Med Imaging, Melbourne, Vic, Australia
[3] Royal Melbourne Hosp, Cardiothorac Surg Unit, Melbourne, Vic, Australia
[4] Univ Melbourne, Dept Surg, Melbourne, Vic, Australia
[5] Univ Melbourne, Dept Med, Melbourne, Vic, Australia
关键词
Radiation; Interventional pulmonology; Lung cancer; Bronchoscopy; PATIENT; CANCER; RISKS;
D O I
10.1159/000539862
中图分类号
R56 [呼吸系及胸部疾病];
学科分类号
摘要
Introduction: Endobronchial radiofrequency ablation (RFA) is a novel minimally invasive approach to management of peripheral non-small-cell lung cancer (NSCLC) in medically inoperable patients. Minimally invasive ablative techniques are generally delivered with cone-beam computed tomography (CBCT) guidance. CBCT requires a significant number of two dimensional imaging projections to be acquired which is then reconstructed as a three-dimensional cone-beam image. The objective of this study was to determine the radiation dosimetry consequent to use of CBCT guidance for bronchoscopic RFA. Methods: Post hoc analysis of data following bronchoscopic RFA of stage I biopsy-confirmed NSCLC performed with CBCT. Effective dose estimates for these patients were calculated using PCXMC2.0 software. Results: Ten patients underwent bronchoscopic RFA, with a median 3 (range 2-4) CBCT spins per procedure. Mean dose area product (DAP) per procedure was 7,778 mu Gy.m2 (+/- 4,743) with an effective dose of 11.6 mSv (+/- 7.4). The DAP per spin for these 10 patients varied from 83.8 to 8,625.6 mu Gy.m2 (effective dose range 0.15-13.81 mSv). Conclusion: This is the first study to report radiation dosimetry consequent to CT guidance for bronchoscopic RFA procedures. Effective doses appear comparable to other CT fluoroscopic procedures.
引用
收藏
页码:498 / 502
页数:5
相关论文
共 50 条
  • [31] Comparison of the Radiation Dose from Cone Beam Computed Tomography and Multidetector Computed Tomography in Examinations of the Hand
    Neubauer, J.
    Neubauer, C.
    Gerstmair, A.
    Krauss, T.
    Reising, K.
    Zajonc, H.
    Kotter, E.
    Langer, M.
    Fiebich, M.
    Voigt, J.
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2016, 188 (05): : 488 - 493
  • [32] MONTE CARLO DOSE ASSESSMENT IN DENTAL CONE-BEAM COMPUTED TOMOGRAPHY
    Kim, Jinwoo
    Jeon, Hosang
    Kim, Ho Kyung
    RADIATION PROTECTION DOSIMETRY, 2021, 193 (3-4) : 190 - 199
  • [33] Cone-beam computed tomography for lung cancer - validation with CT and monitoring tumour response during chemo-radiation therapy
    Michienzi, Alissa
    Kron, Tomas
    Callahan, Jason
    Plumridge, Nikki
    Ball, David
    Everitt, Sarah
    JOURNAL OF MEDICAL IMAGING AND RADIATION ONCOLOGY, 2017, 61 (02) : 263 - 270
  • [34] Megavoltage and Kilovoltage Cone-Beam Computed Tomography Image Guidance for Lung Radiotherapy
    Vlad, M.
    Sixel, K.
    Kosowan, S.
    Hart, M.
    Iqbal, F.
    El-Mallah, M.
    Vandermeer, A.
    MEDICAL PHYSICS, 2011, 38 (06)
  • [35] Incidental Findings From Cone-Beam Computed Tomography During Implant Therapy
    Maska, Bartosz
    Othman, Abdullah
    Behdin, Shabnam
    Benavides, Erika
    Kapila, Yvonne
    CLINICAL ADVANCES IN PERIODONTICS, 2016, 6 (02): : 94 - 98
  • [36] Radiographic assessment of a keratocystic odontogenic tumour using cone-beam computed tomography
    Brauer H.U.
    Diaz C.
    Manegold-Brauer G.
    European Archives of Paediatric Dentistry, 2013, 14 (3) : 173 - 177
  • [37] CONE-BEAM COMPUTED TOMOGRAPHIC IMAGE GUIDANCE FOR LUNG CANCER RADIATION THERAPY
    Bissonnette, Jean-Pierre
    Purdie, Thomas G.
    Higgins, Jane A.
    Li, Winnie
    Bezjak, Andrea
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2009, 73 (03): : 927 - 934
  • [38] EVALUATION OF RECTUM MOTION DURING PELVIC RADIATION USING CONE-BEAM COMPUTED TOMOGRAPHY (CBCT)
    Tomic, N.
    Garant, A.
    Thibault, I.
    Niazi, T.
    Cuthbert, D.
    Bahoric, B.
    Devic, S.
    DeBlois, F.
    Vuong, T.
    RADIOTHERAPY AND ONCOLOGY, 2011, 99 : S462 - S463
  • [40] Evaluating the mandible with cone-beam computed tomography
    Stratemann, Scott A.
    Huang, John C.
    Maki, Koutaro
    Hatcher, David C.
    Miller, Arthur J.
    AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2010, 137 (04) : S58 - S70