Effective Radiation Dose from Cone-Beam Computed Tomography Guidance during Bronchoscopic Tumour Ablation

被引:0
|
作者
Watson, Jack Mitchell [1 ]
Einsiedel, Paul F. [2 ]
Antippa, Phillip [4 ]
Rangamuwa, Kanishka [1 ]
Irving, Louis [1 ]
Steinfort, Daniel P. [1 ,3 ,5 ]
机构
[1] Royal Melbourne Hosp, Dept Resp & Sleep Med, Melbourne, Vic, Australia
[2] Royal Melbourne Hosp, Dept Med Imaging, Melbourne, Vic, Australia
[3] Royal Melbourne Hosp, Cardiothorac Surg Unit, Melbourne, Vic, Australia
[4] Univ Melbourne, Dept Surg, Melbourne, Vic, Australia
[5] Univ Melbourne, Dept Med, Melbourne, Vic, Australia
关键词
Radiation; Interventional pulmonology; Lung cancer; Bronchoscopy; PATIENT; CANCER; RISKS;
D O I
10.1159/000539862
中图分类号
R56 [呼吸系及胸部疾病];
学科分类号
摘要
Introduction: Endobronchial radiofrequency ablation (RFA) is a novel minimally invasive approach to management of peripheral non-small-cell lung cancer (NSCLC) in medically inoperable patients. Minimally invasive ablative techniques are generally delivered with cone-beam computed tomography (CBCT) guidance. CBCT requires a significant number of two dimensional imaging projections to be acquired which is then reconstructed as a three-dimensional cone-beam image. The objective of this study was to determine the radiation dosimetry consequent to use of CBCT guidance for bronchoscopic RFA. Methods: Post hoc analysis of data following bronchoscopic RFA of stage I biopsy-confirmed NSCLC performed with CBCT. Effective dose estimates for these patients were calculated using PCXMC2.0 software. Results: Ten patients underwent bronchoscopic RFA, with a median 3 (range 2-4) CBCT spins per procedure. Mean dose area product (DAP) per procedure was 7,778 mu Gy.m2 (+/- 4,743) with an effective dose of 11.6 mSv (+/- 7.4). The DAP per spin for these 10 patients varied from 83.8 to 8,625.6 mu Gy.m2 (effective dose range 0.15-13.81 mSv). Conclusion: This is the first study to report radiation dosimetry consequent to CT guidance for bronchoscopic RFA procedures. Effective doses appear comparable to other CT fluoroscopic procedures.
引用
收藏
页码:498 / 502
页数:5
相关论文
共 50 条
  • [21] Imaging dose from cone beam computed tomography in radiation therapy
    Alaei, Parham
    Spezi, Emiliano
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2015, 31 (07): : 647 - 658
  • [22] Radiation Dose Estimation From Pediatric Cone Beam Computed Tomography
    Kim, S.
    Yoshizumi, T.
    Toncheva, G.
    Yin, F.
    Frush, D.
    MEDICAL PHYSICS, 2009, 36 (06)
  • [23] Effective Dose during Needle Interventions: Cone-beam CT Guidance Compared with Conventional CT Guidance
    Braak, Sicco J.
    van Strijen, Marco J. L.
    van Es, Hendrik W.
    Nievelstein, Rutger A. J.
    van Heesewijk, Johannes P. M.
    JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2011, 22 (04) : 455 - 461
  • [24] Cone-beam computed tomography imaging: therapeutic staff dose during chemoembolisation procedure
    Paul, Jijo
    Chacko, Annamma
    Mbalisike, Emmanuel C.
    Vogl, Thomas J.
    JOURNAL OF RADIOLOGICAL PROTECTION, 2014, 34 (04) : 843 - 851
  • [25] Cone-beam computed tomography for trauma
    Gupta, Saurabh
    Martinson, James R.
    Ricaurte, Daniel
    Scalea, Thomas M.
    Morrison, Jonathan J.
    JOURNAL OF TRAUMA AND ACUTE CARE SURGERY, 2020, 89 (03): : E34 - E40
  • [26] Cone-Beam Computed Tomography in Orthodontics
    Abdelkarim, Ahmad
    DENTISTRY JOURNAL, 2019, 7 (03)
  • [27] Evaluation of radiation dose and image quality for dental cone-beam computed tomography in pediatric patients
    Ito, Misaki
    Chida, Koichi
    Onodera, Shu
    Kojima, Ikuho
    Iikubo, Masahiro
    Kato, Toshiki
    Fujisawa, Masaki
    Zuguchi, Masayuki
    JOURNAL OF RADIOLOGICAL PROTECTION, 2023, 43 (03)
  • [28] A new formula for converting dose-area product to effective dose in dental cone-beam computed tomography
    Pauwels, Ruben
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2023, 112
  • [29] Variations in head tilt during the acquisition of cone beam computed tomography scans and their effects on effective radiation dose
    Mancini, Arthur X. M.
    Carmozini, Gabriela A.
    Inacio, Thiago M.
    Rea, Marcela T.
    Viccari, Cassiana
    Brasil, Danieli M.
    Oliveira-Santos, Christiano
    DENTOMAXILLOFACIAL RADIOLOGY, 2024, 53 (08) : 566 - 572
  • [30] ACCURACY AND DOSE OF A CONE-BEAM COMPUTED TOMOGRAPHY FOR STEREOTACTIC RADIOSURGERY SETUP
    Sancho, I.
    Modolell, I.
    Ferrer, F.
    Lizuain, M. C.
    RADIOTHERAPY AND ONCOLOGY, 2010, 96 : S422 - S422