Color Stability of Various Orthodontic Clear Aligner Systems after Submersion in Different Staining Beverages

被引:1
|
作者
Olteanu, Nicolae Daniel [1 ]
Taraboanta, Ionut [1 ]
Panaite, Tinela [1 ]
Balcos, Carina [1 ]
Rosu, Sorana Nicoleta [1 ]
Vieriu, Raluca Maria [1 ]
Dinu, Stefania [2 ]
Zetu, Irina Nicoleta [1 ]
机构
[1] Univ Med & Pharm Iasi, Fac Dent Med Grigore T Popa, Dept Oral & Maxillofacial Surg, Str Univ 16, Iasi 700115, Romania
[2] Victor Babe Univ Med & Pharm Timisoara, Fac Dent Med, Dept Pedodont, 9 Revolutiei Bv, Timisoara 300041, Romania
关键词
clear aligner; polyethylene terephthalate glycol; thermoplastic elastomer; color stability; staining beverages; MECHANICAL-PROPERTIES; THERMOPLASTIC MATERIALS; WATER SORPTION; COMPOSITES; ROUGHNESS;
D O I
10.3390/ma17164009
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
This study aimed to compare the color changes in two different orthodontic clear aligner systems after submersion in various beverages for 14 days. The tested aligner systems were Taglus Premium made of polyethylene terephthalate glycol (the TAG group) and CA (R) Prodin+ made of a transparent copolyester and a thermoplastic elastomer (the PRO group). A total of 56 samples were firstly divided into two groups according to the tested system-TAG and PRO. Each group was subsequently divided in four subgroups according to immersion solution: A-artificial saliva, B-cola, C-coffee, D-red wine. Color measurements were performed on Days 1, 7 and 14 using a portable colorimeter and the CIE L*a*b* system. The obtained results showed significant color changes in both materials when exposed to coffee and red wine (p > 0.05). Samples in the PRO group showed a greater susceptibility to discoloration (higher Delta E values) when compared to the TAG group after submersion in cola (p = 0.025), coffee (p = 0.005) and red wine (p = 0.041) solutions. Statistical analysis revealed that all of the color parameters Delta L*, Delta a*, Delta b* and Delta E of both tested materials were affected by submersion in coffee solution for 14 days. In conclusion, the CA (R) Pro+ aligner system is more prone to staining compared to the Taglus material after submersion for 14 days in cola, coffee and red wine solutions. Submersion for 14 days in coffee solution alters all of the color parameters (Delta L, Delta a, Delta b and Delta E) of both tested aligner materials.
引用
收藏
页数:11
相关论文
共 50 条
  • [41] The Effect of Coloring Beverages on Color Stability of Hybrid Ceramics with Different Surface Treatments
    Jalali, Hamid
    Mostafavi, Azam Sadat
    Balaghi, Fatemeh
    PESQUISA BRASILEIRA EM ODONTOPEDIATRIA E CLINICA INTEGRADA, 2022, 22
  • [42] Effects of different beverages on the color stability and fluorescence of resin composites: in situ study
    Oliveira, Lara Pepita de Souza
    Silva, Jardel dos Santos
    da Mata e Silva, Luciana
    Leal, Cristiane Maria Brasil
    Regalado, Diego Ferreira
    Toda, Carina
    Pontes, Danielson Guedes
    CLINICAL ORAL INVESTIGATIONS, 2024, 28 (10)
  • [43] In vitro study on the impact of various polishing systems and coffee staining on the color stability of bleach-shaded resin composite
    Jrady, Ali
    Ragab, Hala
    Algahtani, Fahda N.
    Osman, Essam
    BMC ORAL HEALTH, 2024, 24 (01):
  • [44] Colorimetric Evaluation of Various Orthodontic Thermoformed Retainers Exposed to Different Staining Agents and Cleaning Techniques
    Singh, Swati
    Jain, Ravindra Kumar
    JOURNAL OF INTERNATIONAL ORAL HEALTH, 2024, 16 (03): : 205 - 213
  • [45] Effect of different polishing systems and staining solution on surface roughness and color stability of bulk fill resin composites
    do Nascimento, Helanne de Oliveira
    Vieira, Waldemir Francisco, Jr.
    Basting, Roberta Tarkany
    Turssi, Cecilia Pedroso
    Botelho do Amaral, Flavia Lucisano
    Gomes Franca, Fabiana Mantovani
    AMERICAN JOURNAL OF DENTISTRY, 2022, 35 (01): : 37 - 42
  • [46] Color stability of denture resins after staining and exposure to cleansing agents
    Hollis, Scott
    Eisenbeisz, Elaine
    Versluis, Antheunis
    JOURNAL OF PROSTHETIC DENTISTRY, 2015, 114 (05): : 709 - 714
  • [47] Color stability of lithium disilicate ceramics after aging and immersion in common beverages
    Palla, Eleni-Sotiria
    Kontonasaki, Eleana
    Kantiranis, Nikolaos
    Papadopoulou, Lambrini
    Zorba, Triantafyllia
    Paraskevopoulos, Konstantinos M.
    Koidis, Petros
    JOURNAL OF PROSTHETIC DENTISTRY, 2018, 119 (04): : 632 - 642
  • [48] Color Stability of Dental Composites after Immersion in Beverages and Performed Whitening Procedures
    Korac, Samra
    Ajanovic, Muhamed
    Dzankovic, Aida
    Konjhodzic, Alma
    Hasic-Brankovic, Lajla
    Gavranovic-Glamoc, Alma
    Tahmiscija, Irmina
    ACTA STOMATOLOGICA CROATICA, 2022, 56 (01) : 22 - 32
  • [49] Effect of Acidic Beverages on Color Stability and Microhardness of Various Esthetic Restorative Materials: A Comparative Study
    Rathod, Aradhana
    Vadavadagi, Suneel V.
    Verma, Tanya
    Kumar, Pawan
    Deepak, Potluri Venkataratna
    Deb, Saikat
    Iqbal, Azhar
    JOURNAL OF PHARMACY AND BIOALLIED SCIENCES, 2021, 13 (06): : S1084 - S1087
  • [50] Evaluation of the Effect of Various Beverages and Food Materials on the Color Stability of Provisional Materials: An In Vitro Study
    Fatima, Tanveer
    Abubakar, Parvez
    Deshpande, Sumit
    Afreen, Nazia
    Sheshnag, G.
    Safoora, Syeda
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2024, 16 (07)