Color Stability of Various Orthodontic Clear Aligner Systems after Submersion in Different Staining Beverages

被引:1
|
作者
Olteanu, Nicolae Daniel [1 ]
Taraboanta, Ionut [1 ]
Panaite, Tinela [1 ]
Balcos, Carina [1 ]
Rosu, Sorana Nicoleta [1 ]
Vieriu, Raluca Maria [1 ]
Dinu, Stefania [2 ]
Zetu, Irina Nicoleta [1 ]
机构
[1] Univ Med & Pharm Iasi, Fac Dent Med Grigore T Popa, Dept Oral & Maxillofacial Surg, Str Univ 16, Iasi 700115, Romania
[2] Victor Babe Univ Med & Pharm Timisoara, Fac Dent Med, Dept Pedodont, 9 Revolutiei Bv, Timisoara 300041, Romania
关键词
clear aligner; polyethylene terephthalate glycol; thermoplastic elastomer; color stability; staining beverages; MECHANICAL-PROPERTIES; THERMOPLASTIC MATERIALS; WATER SORPTION; COMPOSITES; ROUGHNESS;
D O I
10.3390/ma17164009
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
This study aimed to compare the color changes in two different orthodontic clear aligner systems after submersion in various beverages for 14 days. The tested aligner systems were Taglus Premium made of polyethylene terephthalate glycol (the TAG group) and CA (R) Prodin+ made of a transparent copolyester and a thermoplastic elastomer (the PRO group). A total of 56 samples were firstly divided into two groups according to the tested system-TAG and PRO. Each group was subsequently divided in four subgroups according to immersion solution: A-artificial saliva, B-cola, C-coffee, D-red wine. Color measurements were performed on Days 1, 7 and 14 using a portable colorimeter and the CIE L*a*b* system. The obtained results showed significant color changes in both materials when exposed to coffee and red wine (p > 0.05). Samples in the PRO group showed a greater susceptibility to discoloration (higher Delta E values) when compared to the TAG group after submersion in cola (p = 0.025), coffee (p = 0.005) and red wine (p = 0.041) solutions. Statistical analysis revealed that all of the color parameters Delta L*, Delta a*, Delta b* and Delta E of both tested materials were affected by submersion in coffee solution for 14 days. In conclusion, the CA (R) Pro+ aligner system is more prone to staining compared to the Taglus material after submersion for 14 days in cola, coffee and red wine solutions. Submersion for 14 days in coffee solution alters all of the color parameters (Delta L, Delta a, Delta b and Delta E) of both tested aligner materials.
引用
收藏
页数:11
相关论文
共 50 条
  • [21] Comparative Assessment of Orthodontic and Aesthetic Outcomes after Orthognathic Surgery with Clear Aligner or Fixed Appliance Therapy
    Liou, Yu-Jia
    Chen, Pin-Ru
    Tsai, Tzong-Yueh
    Lin, Susie
    Chou, Pang-Yun
    Lo, Chiu-Mei
    Chen, Yu-Ray
    PLASTIC AND RECONSTRUCTIVE SURGERY, 2024, 154 (01) : 162 - 172
  • [22] Color Stability of Resin Used for Caries Infiltration After Exposure to Different Staining Solutions
    Borges, A. B.
    Caneppele, T. M. F.
    Luz, M.
    Pucci, C. R.
    Torres, C. R. G.
    OPERATIVE DENTISTRY, 2014, 39 (04) : 433 - 440
  • [23] Evaluation of the effect of various beverages on the color stability and microhardness of restorative materials
    Ozkanoglu, S.
    Akin, E. G. G.
    NIGERIAN JOURNAL OF CLINICAL PRACTICE, 2020, 23 (03) : 322 - 328
  • [24] Color stability and force decay of clear orthodontic elastomeric chains: An in vitro study
    Aldrees, Abdullah M.
    Al-Foraidi, Sahal A.
    Murayshed, Mohammed S.
    Almoammar, Khalid A.
    INTERNATIONAL ORTHODONTICS, 2015, 13 (03) : 287 - 301
  • [25] Color stability of hybrid ceramics exposed to beverages in different combinations
    Yerliyurt, Kaan
    Sarikaya, Isil
    BMC ORAL HEALTH, 2022, 22 (01)
  • [26] Color stability of hybrid ceramics exposed to beverages in different combinations
    Kaan Yerliyurt
    Işıl Sarıkaya
    BMC Oral Health, 22
  • [27] Optimized Attachment to Achieve Different Buccolingual Movement of Maxillary Molars in Clear Aligner Orthodontic System: Biomechanical Analysis
    Qin, Long
    Wang, Qiao
    Zhang, Dongliang
    He, Xin
    Wu, Binbin
    NANOSCIENCE AND NANOTECHNOLOGY LETTERS, 2020, 12 (11) : 1249 - 1254
  • [28] Discussion: Comparative Assessment of Orthodontic and Aesthetic Outcomes after Orthognathic Surgery with Clear Aligner or Fixed Appliance Therapy
    Susarla, Srinivas M.
    Sheller, Barbara
    Kapadia, Hitesh
    PLASTIC AND RECONSTRUCTIVE SURGERY, 2024, 154 (01) : 173 - 174
  • [29] Color Stability of Monolithic Zirconia in Various Staining Liquids: An In Vitro Study
    Alnassar, Talal M.
    APPLIED SCIENCES-BASEL, 2022, 12 (19):
  • [30] Effect of Different pH Beverages on the Color Stability of Smart Monochromatic Composite
    Ahmed, Muhammad Adeel
    Jouhar, Rizwan
    Vohra, Fahim
    APPLIED SCIENCES-BASEL, 2022, 12 (09):