Autonomous Calibration of Blood Pressure Dependent Data Using Second-Order Blood Pressure Variation for a Future Mobile Diagnostic: Requirements for a Calibration

被引:0
|
作者
Deutges, Martin [1 ]
Redtel, Holger [1 ]
机构
[1] Redtel, D-19348 Perleberg, Germany
来源
IEEE ACCESS | 2024年 / 12卷
关键词
Blood pressure; Calibration; Pressure measurement; Biomedical monitoring; Estimation; Current measurement; Blood pressure measurement; Photoplethysmography; calibration; cuff pressure simulation; oscillometric blood pressure measurement; photoplethysmography (PPG); pulse transit time (PTT); respiration; second-order blood pressure variation; systematic error; Traube wave; EXERCISE; RESPIRATION; VALIDATION; CUFF;
D O I
10.1109/ACCESS.2024.3426984
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Currently, blood pressure assessment is on the verge of shifting from classical cuff-based measurements to continuous estimation using smart devices based on the absorption and reflection characteristics of light in tissue. This type of blood pressure estimation has been known for a long time and depends on calibration with conventional blood pressure measurement systems. Products from well-known manufacturers in this market already perform calibration with automatic cuffs using an oscillometric estimation. The main aim is to show that classical oscillometric blood pressure estimation is not suitable for calibration, which allows a burden-free and continuous estimation by today's approaches. This study identifies the reason and also the solution for this in the second-order blood pressure variation. The current approach to oscillometric estimation of blood pressure has an uncorrectable systematic error of the order of the second-order blood pressure variation. Therefore the current method has too much error to be used as a basis for calibration to allow continuous estimation of blood pressure based on another vital parameter. It is shown that when using a measurement of the second-order blood pressure variation as basis for such calibration this problem can be solved.
引用
收藏
页码:97269 / 97279
页数:11
相关论文
共 37 条
  • [31] Arterial blood pressure assessed using numerical modelling of DICOM data and Finite Element Analysis shows marked variation dependent on cuff construction and materials
    Lewis, Philip
    Naqvi, Shenela
    Mandal, Parthasarathi
    Potluri, Prasad
    JOURNAL OF HUMAN HYPERTENSION, 2015, 29 (10) : 638 - 638
  • [32] Cuff-less Calibration-free Blood Pressure Estimation under Ambulatory Environment using Pulse Wave Velocity and Photoplethysmogram Signals
    Sanuki, Haruyuki
    Rui Fukui
    Inajima, Tsukasa
    Warisawa, Shin'ichi
    PROCEEDINGS OF THE 10TH INTERNATIONAL JOINT CONFERENCE ON BIOMEDICAL ENGINEERING SYSTEMS AND TECHNOLOGIES, VOL 4: BIOSIGNALS, 2017, : 42 - 48
  • [33] Central-to-peripheral blood pressure amplification: role of the recording site, technology, analysis approach, and calibration scheme in invasive and non-invasive data agreement
    Zocalo, Yanina
    Bia, Daniel
    Sanchez, Ramiro
    Lev, Gustavo
    Mendiz, Oscar
    Ramirez, Agustin
    Cabrera-Fischer, Edmundo I.
    FRONTIERS IN CARDIOVASCULAR MEDICINE, 2023, 10
  • [34] P52 Estimating Central Blood Pressure from Mri Data using Reduced-Order Computational Models
    Jorge Mariscal Harana
    Peter H. Charlton
    Samuel Vennin
    Arna van Engelen
    Torben Schneider
    Mateusz Florkow
    Hubrecht de Bliek
    Bram Ruijsink
    Israel Valverde
    Marietta Charakida
    Kuberan Pushparajah
    Spencer Sherwin
    Rene Botnar
    Jordi Alastruey
    Artery Research, 2018, 24 (1) : 93 - 94
  • [36] An investigation of the individualized, two-point calibration method for cuffless blood pressure estimation using pulse arrival time: an historical perspective using the Casio BP-100 digital watch
    Louka, Kyrollos
    Cox, James
    Tan, Isabella
    Avolio, Alberto P.
    O'Rourke, Michael F.
    Butlin, Mark
    2021 43RD ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE & BIOLOGY SOCIETY (EMBC), 2021, : 7493 - 7496
  • [37] Three-way calibration using PARAFAC and MCR-ALS with previous synchronization of second-order chromatographic data through a new functional alignment of pure vectors for the quantification in the presence of retention time shifts in peak position and shape
    Mazivila, Sarmento J.
    Lombardi, Juan M.
    Pascoa, Ricardo N. M. J.
    Bortolato, Santiago A.
    Leitao, Joao M. M.
    Esteves da Silva, Joaquim C. G.
    ANALYTICA CHIMICA ACTA, 2021, 1146 : 98 - 108