Autonomous Calibration of Blood Pressure Dependent Data Using Second-Order Blood Pressure Variation for a Future Mobile Diagnostic: Requirements for a Calibration

被引:0
|
作者
Deutges, Martin [1 ]
Redtel, Holger [1 ]
机构
[1] Redtel, D-19348 Perleberg, Germany
来源
IEEE ACCESS | 2024年 / 12卷
关键词
Blood pressure; Calibration; Pressure measurement; Biomedical monitoring; Estimation; Current measurement; Blood pressure measurement; Photoplethysmography; calibration; cuff pressure simulation; oscillometric blood pressure measurement; photoplethysmography (PPG); pulse transit time (PTT); respiration; second-order blood pressure variation; systematic error; Traube wave; EXERCISE; RESPIRATION; VALIDATION; CUFF;
D O I
10.1109/ACCESS.2024.3426984
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Currently, blood pressure assessment is on the verge of shifting from classical cuff-based measurements to continuous estimation using smart devices based on the absorption and reflection characteristics of light in tissue. This type of blood pressure estimation has been known for a long time and depends on calibration with conventional blood pressure measurement systems. Products from well-known manufacturers in this market already perform calibration with automatic cuffs using an oscillometric estimation. The main aim is to show that classical oscillometric blood pressure estimation is not suitable for calibration, which allows a burden-free and continuous estimation by today's approaches. This study identifies the reason and also the solution for this in the second-order blood pressure variation. The current approach to oscillometric estimation of blood pressure has an uncorrectable systematic error of the order of the second-order blood pressure variation. Therefore the current method has too much error to be used as a basis for calibration to allow continuous estimation of blood pressure based on another vital parameter. It is shown that when using a measurement of the second-order blood pressure variation as basis for such calibration this problem can be solved.
引用
收藏
页码:97269 / 97279
页数:11
相关论文
共 37 条
  • [21] Calibration of blood pressure data after replacement of the standard mercury sphygmomanometer by an oscillometric device and concurrent change of cuffs
    Neuhauser, Hannelore K.
    Ellert, Ute
    Thamm, Michael
    Adler, Carolin
    BLOOD PRESSURE MONITORING, 2015, 20 (01) : 39 - 42
  • [22] A PPG-Based Calibration-Free Cuffless Blood Pressure Estimation Method Using Cardiovascular Dynamics
    Samimi, Hamed
    Dajani, Hilmi R.
    SENSORS, 2023, 23 (08)
  • [23] Determination of danofloxacin in milk combining second-order calibration and standard addition method using excitation-emission fluorescence data
    Canada-Canada, Florentina
    Espinosa-Mansilla, Anunciacion
    de la Pena, Arsenio Munoz
    Giron, Ana Jimnez
    Gonzalez-Gromez, David
    FOOD CHEMISTRY, 2009, 113 (04) : 1260 - 1265
  • [24] Blind, Cuff-less, Calibration-Free and Continuous Blood Pressure Estimation using Optimized Inductive Group Method of Data Handling
    Mohebbian, Mohammad Reza
    Anh Dinh
    Wahid, Khan
    Alam, Mohammad Sami
    BIOMEDICAL SIGNAL PROCESSING AND CONTROL, 2020, 57
  • [25] Cuff-less and Calibration-free Blood Pressure Estimation Using Convolutional Autoencoder with Unsupervised Feature Extraction
    Zhang, Jialun
    Wu, Dan
    Li, Ye
    2019 41ST ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2019, : 3323 - 3326
  • [26] Pulmonary Artery Systolic Blood Pressure Predicted From Cardiac MR Image Data Without Requiring Calibration; A Virtual RHC?
    Doyle, Mark
    Rayarao, Geetha
    Lacson, Roger
    Hussain, Nasir
    Biederman, Robert W.
    CIRCULATION, 2021, 144
  • [27] P7.16 Validation of an Oscillometric Brachial Cuff Method to Derive Central Blood Pressure Using Different Calibration Modes
    Martin Schultz
    Ahmad Qasem
    Xiaoqing Peng
    Dean Picone
    J. Andrew Black
    Nathan Dwyer
    Phillip Roberts-Thomson
    James Sharman
    Artery Research, 2015, 12 (1) : 33 - 33
  • [28] Cuff-Less High-Accuracy Calibration-Free Blood Pressure Estimation Using Pulse Transit Time
    Kachuee, Mohamad
    Kiani, Mohammad Mahdi
    Mohammadzade, Hoda
    Shabany, Mahdi
    2015 IEEE INTERNATIONAL SYMPOSIUM ON CIRCUITS AND SYSTEMS (ISCAS), 2015, : 1006 - 1009
  • [29] Determination of Daunomycin in Human Plasma and Urine by Using an Interference-free Analysis of Excitation-Emission Matrix Fluorescence Data with Second-Order Calibration
    A-Lin Xia
    Hai-Long Wu
    Dong-Mei Fang
    Yu-Jie Ding
    Le-Qian Hu
    Ru-Qin Yu
    Analytical Sciences, 2006, 22 : 1189 - 1195
  • [30] Determination of daunomycin in human plasma and urine by using an interference-free analysis of excitation-emission matrix fluorescence data with second-order calibration
    Xia, A-Lin
    Wu, Hai-Long
    Fang, Dong-Mei
    Ding, Yu-Jie
    Hu, Le-Qian
    Yu, Ru-Qin
    ANALYTICAL SCIENCES, 2006, 22 (09) : 1189 - 1195