Interference screw versus suture button fixation for tibialis anterior tendon transfer: a biomechanical analysis

被引:0
|
作者
Meyer, Zachary [1 ]
Bohl, Daniel [2 ]
Zide, Jacob [3 ]
Pierce, William [4 ]
Niese, Brad [4 ]
Shivers, Claire [4 ]
Polk, Jordan [4 ]
Kannan, Yassine [4 ]
Riccio, Anthony I. [4 ]
机构
[1] Washington Univ, Dept Orthopaediatr Surg, Med Ctr, St Louis, MO USA
[2] Rush Univ, Med Ctr, Dept Orthopaed Surg, Chicago, IL USA
[3] Baylor Univ, Med Ctr, Dept Orthopaed Surg, Dallas, TX USA
[4] Scottish Rite Children, Dept Orthopaed Surg, Dallas, TX USA
来源
关键词
clubfoot; interference screw; lateral cuneiform; recurrence; suture button; tibialis anterior tendon transfer;
D O I
10.1097/BPB.0000000000001131
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Tibialis anterior tendon (TAT) transfer to the lateral cuneiform is commonly utilized to treat dynamic supination for relapsed clubfoot deformity. Traditional suture button fixation (SBF) may lead to skin necrosis at the button/skin interface. While interference screw fixation (ISF) would mitigate this concern, this fixation method has not been investigated in clubfoot patients. This study aims to investigate the performance of ISF versus SBF for TAT transfer in a cadaveric model. Ten matched pairs of cadaveric feet were obtained. One of each matched specimen underwent TAT transfer to the lateral cuneiform using ISF and the other underwent TAT transfer using SBF. For each ISF specimen, the tension of the transferred TAT required to bring the ankle to neutral was measured. This tension was then applied to both matched specimens using an MTS machine. Tension dissipation was measured after a 20-minute interval. In specimens with SBF, a load cell was positioned between the plantar skin and suture button to determine plantar skin pressure at the time of initial tension application. Average tension necessary to achieve neutral dorsiflexion was 49.4 N. Average tension dissipation after 20 min was significantly less in the IFS group (20 N versus 23.6 N, P = 0.02). No fixation failures occurred in either group. Average plantar foot skin pressure was 196.5 mmHg at initial tension application, exceeding thresholds for tissue ischemia. ISF allows for tendon tensioning at forces beyond those expected to result in skin necrosis with SBF with less dissipation of tension over time.
引用
收藏
页码:503 / 506
页数:4
相关论文
共 50 条
  • [1] Suture-Button Versus Screw Fixation of the Syndesmosis: A Biomechanical Analysis
    Klitzman, Robert
    Zhao, Heng
    Zhang, Li-Qun
    Strohmeyer, Greg
    Vora, Anand
    FOOT & ANKLE INTERNATIONAL, 2010, 31 (01) : 69 - 75
  • [2] Allograft anterior tibialis tendon with bioabsorbable interference screw fixation in anterior cruciate ligament reconstruction
    Caborn, DNM
    Selby, JB
    ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2002, 18 (01): : 102 - 105
  • [3] Biomechanical study of tibialis anterior tendon transfer
    Hui, JHP
    Goh, JCH
    Lee, EH
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1998, (349) : 249 - 255
  • [4] Suture-Button Versus Screw Fixation in a Syndesmosis Rupture Model: A Biomechanical Comparison
    Soin, Sandeep P.
    Knight, Trevor A.
    Dinah, A. Feroz
    Mears, Simon C.
    Swierstra, Bart A.
    Belkoff, Stephen M.
    FOOT & ANKLE INTERNATIONAL, 2009, 30 (04) : 346 - 352
  • [5] Biomechanical Strength of Screw Versus Suture Button Fixation in the Latarjet Procedure: A Cadaver Study
    Hakverdiyev, Yasin
    Mcfarland, Edward G.
    Kaymakoglu, Mehmet
    Ozdemir, Erdi
    Akpinar, Sercan
    Huri, Pinar
    Costouros, John G.
    Huri, Gazi
    ORTHOPEDICS, 2022, 45 (06) : E321 - E325
  • [6] Adjustable-length loop cortical button versus interference screw fixation in quadriceps tendon anterior cruciate ligament reconstruction - A biomechanical in vitro study
    Karkosch, Roman Frederik
    Ettinger, Max
    Bachmaier, Samuel
    Wijdicks, Coen A.
    Smitha, Tomas
    CLINICAL BIOMECHANICS, 2018, 60 : 60 - 65
  • [7] Comparison of Staple, Anchor, and Tenodesis Screw for Posterior Tibialis Tendon Fixation: A Biomechanical Analysis
    Aslan, Lercan
    Gunerbuyuk, Caner
    Gedik, Cemil Cihad
    Sarabi, Misagh Rezapour
    Kilicoglu, Onder
    JOURNAL OF FOOT & ANKLE SURGERY, 2024, 63 (02): : 194 - 198
  • [8] Biomechanical Analysis of a Novel Syndesmotic Plate Compared With Traditional Screw and Suture Button Fixation
    Weng, Qihao
    Lin, Chuanlu
    Liu, Yang
    Dai, Gaole
    Lutchooman, Vinesh
    Hong, Jianjun
    JOURNAL OF FOOT & ANKLE SURGERY, 2020, 59 (03): : 522 - 528
  • [9] Lateral Cuneiform Ossification and Tibialis Anterior Tendon Width in Children Ages 3 to 6: Implications for Interference Screw Fixation of Tibialis Anterior Tendon Transfers in Children
    Meyer, Zachery, I
    Polk, Jordan L.
    Zide, Jacob R.
    Kanaan, Yassine
    Riccio, Anthony, I
    JOURNAL OF PEDIATRIC ORTHOPAEDICS, 2022, 42 (04) : 229 - 232
  • [10] A Biomechanical Evaluation of Bicortical Metal Screw Fixation Versus Absorbable Interference Screw Fixation After Coracoid Transfer for Anterior Shoulder Instability
    Weppe, Florent
    Magnussen, Robert A.
    Lustig, Sebastien
    Demey, Guillaume
    Neyret, Philippe
    Servien, Elvire
    ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2011, 27 (10): : 1358 - 1363