Comparison of visual outcomes of bilateral dual-technology diffractive intraocular lens vs blended enhanced monofocal with dual-technology intraocular lens

被引:2
|
作者
Hida, Wilson Takashi [1 ,2 ]
Moscovici, Bernardo Kaplan [3 ]
Cortez, Cesar Martins [1 ,4 ,5 ]
Colombo-Barboza, Guilherme Novoa
Tzelikis, Patrick Frensel de Moraes [1 ,4 ,5 ]
Motta, Antonio Francisco Pimenta [4 ,5 ]
De Medeiros, Andre Lins [4 ,5 ]
Nose, Walton [3 ,5 ]
Carricondo, Pedro Carlos [2 ]
机构
[1] Hosp Oftalmol Brasilia HOB, Dept Ophthalmol, Brasilia, Brazil
[2] Univ Sao Paulo HC FMUSP, Dept Ophthalmol, Sao Paulo, Brazil
[3] Fed Univ Sao Paulo UNIFESP, Dept Ophthalmol & Visual Sci, Sao Paulo, Brazil
[4] Hosp Visao Laser, Dept Ophthalmol, Santos, Brazil
[5] Renato Ambrosio Res Ctr CEORA, Dept Ophthalmol, Brasilia, Brazil
来源
关键词
DEPTH-OF-FOCUS; EXTENDED DEPTH; PATIENT SATISFACTION; IMPLANTATION; PERFORMANCE; RANGE; ZXR00;
D O I
10.1097/j.jcrs.0000000000001374
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To compare clinical outcomes after implantation of TECNIS Synergy (ZFR00V) intraocular lenses (IOLs) in both eyes and implantation of the TECNIS Synergy and TECNIS Eyhance (ICB00) combination in patients undergoing cataract surgery. Setting: Department of Cataract, Hospital Oftalmol & oacute;gico de Brasilia (HOB), Bras & iacute;lia, Brazil. Design: Prospective, interventional, randomized, parallel-group study. Methods: Patients were categorized into 2 groups: Group 1: ZFR00V IOL was implanted in both eyes. Group 2: An ICB00 IOL was implanted in the dominant eye, and a ZFR00V IOL was implanted in the nondominant eye. Results: Visual acuity was similar between the 2 groups (95% CI <0.1 logMAR). A superior visual acuity of >= 20/25 (at -2.00 to -2.50 diopters [D]) was achieved in Group 1 (bilateral ZFR00V) than in Group 2 (combination of ZFR00V/ICB00). The binocular defocus curve demonstrated better visual acuity at 40 cm (-2.00 D) and 50 cm (-2.50 D) in Group 1 than in Group 2 (P < .05). Similar contrast sensitivity values were observed between the 2 groups. Patients in Group 1 reported higher satisfaction (completely satisfied) than those in Group 2 (P < .05). However, halos and glare were more pronounced in Group 1 than in Group 2 (P < .05). Conclusions: Both presbyopia-correcting IOL combinations showed similar binocular visual acuity results. Group 1 demonstrated enhanced visual acuity in the defocus curve at 40 cm (-2.00 D) and 50 cm (-2.50 D). Comparable contrast sensitivity outcomes were observed in both groups. Patients were more completely satisfied in Group 1 than in Group 2, despite the higher frequency of postoperative nighttime halos and glare.
引用
收藏
页码:401 / 406
页数:6
相关论文
共 50 条
  • [31] Comparison of visual outcomes of a diffractive trifocal intraocular lens and a refractive bifocal intraocular lens in eyes with axial myopia: a prospective cohort study
    Tong Sun
    Yiyun Liu
    Yufei Gao
    Chuhao Tang
    Qianqian Lan
    Tingting Yang
    Xiaorui Zhao
    Hong Qi
    BMC Ophthalmology, 22
  • [32] Extending the range of vision using diffractive intraocular lens technology
    Weeber, Henk A.
    Meijer, Sieger T.
    Piers, Patricia A.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2015, 41 (12): : 2746 - 2754
  • [33] Comparison of visual outcomes of a diffractive trifocal intraocular lens and a refractive bifocal intraocular lens in eyes with axial myopia: a prospective cohort study
    Sun, Tong
    Liu, Yiyun
    Gao, Yufei
    Tang, Chuhao
    Lan, Qianqian
    Yang, Tingting
    Zhao, Xiaorui
    Qi, Hong
    BMC OPHTHALMOLOGY, 2022, 22 (01)
  • [34] Optical and Clinical Outcomes of an Enhanced Monofocal Intraocular Lens for High Hyperopia
    Fernandez-Vega-Cueto, Luis
    Vega, Fidel
    Guerra-Velasco, Raquel
    Millan, Maria S.
    Madrid-Costa, David
    Alfonso, Jose F.
    JOURNAL OF REFRACTIVE SURGERY, 2022, 38 (09) : 572 - +
  • [35] Visual Outcomes and Patient Satisfaction of Enhanced Monofocal Intraocular Lens in Phacovitrectomy for Idiopathic Epiretinal Membrane
    Choi, Ji Youn
    Won, Yeo Kyoung
    Lee, Soo Jin
    Kang, Se Woong
    Lim, Dong Hui
    BIOENGINEERING-BASEL, 2024, 11 (09):
  • [36] Visual outcomes and optical performance with a monofocal intraocular lens and a new-generation single-optic accommodating intraocular lens
    Alio, Jorge L.
    Pinero, David P.
    Plaza-Puche, Ana B.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2010, 36 (10): : 1656 - 1664
  • [37] Visual outcomes and patient satisfaction after bilateral implantation of a new trifocal diffractive intraocular lens
    Almulhim, Abdulmohsen K.
    Alarfaj, Khalid M.
    Altaisan, Abdulaziz A.
    Alromaih, Arwa Z.
    Aldawod, Razan A.
    SAUDI JOURNAL OF OPHTHALMOLOGY, 2018, 32 (04) : 310 - 317
  • [38] Visual outcomes and subjective experience after bilateral implantation of a new diffractive trifocal intraocular lens
    Sheppard, Amy L.
    Shah, Sunil
    Bhatt, Uday
    Bhogal, Gurpreet
    Wolffsohn, James S.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2013, 39 (03): : 343 - 349
  • [39] Comparison of Visual Functions After Cataract Operations in Which Bilateral Multifocal and Monofocal Intraocular Lens Implanted
    Mesci, Cem
    Erbil, Hasan Hasbi
    Ozdoker, Levent
    Yakut, Sinan
    TURK OFTALMOLOJI DERGISI-TURKISH JOURNAL OF OPHTHALMOLOGY, 2008, 38 (04): : 305 - 309
  • [40] Visual and refractive outcomes of monofocal toric intraocular lens implantation in amblyopic eyes
    Rementeria-Capelo, Laureano A.
    Fernandez-Cuenca, Sara
    Gros-Otero, Juan
    Garcia-Perez, Jorge L.
    Moran, Aida
    Contreras, Ines
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2022, 32 (06) : 3425 - 3432