Endoscopic Endonasal Occipitocervical Fixation with a Customized Three-Dimensional Printed Titanium Plate-Screw Construct: A Cadaveric Feasibility Study

被引:0
|
作者
Kaye, Joel [1 ]
Na, John [1 ]
Stephan, Katarina [1 ]
Bal, Ella [1 ]
Nebor, Ivanna [1 ]
Bucherl, Sean [2 ]
Nauman, Eric [2 ]
Nasser, Rani [1 ]
Virojanapa, Justin [1 ]
Andaluz, Norberto [1 ]
Forbes, Jonathan A. [1 ]
机构
[1] Univ Cincinnati, Coll Med, Dept Neurol Surg, Cincinnati, OH 45221 USA
[2] Univ Cincinnati, Coll Engn & Appl Sci, Dept Biomed Engn, Cincinnati, OH USA
关键词
Craniocervical junction; Endonasal; Occipitocervical fusion; Odontoidectomy; VENTRAL CRANIOCERVICAL JUNCTION; CRANIOVERTEBRAL JUNCTION; BIOMECHANICAL EVALUATION; RESECTION; PLACEMENT; STABILITY; EXPOSURE; C1-C2;
D O I
10.1016/j.wneu.2024.07.055
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
OBJECTIVE: To evaluate the feasibility of a novel method for occipitocervical fixation (OCF) through the endonasal corridor. METHODS: Thin-cut computed tomography scans were obtained for 5 cadaveric specimens. Image segmentation was used to reconstruct 3D models of each O-C1 joint complex. Using computer-aided design software, plates were custom-designed to span each O-C1 joint, sit flush onto the bony surface, and accommodate screws. The final models were 3D-printed in titanium. For implantation, specimens were held in pin-fixation and registered to neuronavigation. A rigid 0o endoscope was used for endonasal visualization. An inverted U-shaped nasopharyngeal flap was raised to expose the occipital condyles and C1. The plates were introduced and fixed with bone screws. Computed tomography scans were obtained to assess screw accuracy and proximity to critical neurovascular structures. Screw entry points and trajectories were recorded. RESULTS: Endonasal OCF was performed on 5 cadaveric specimens. The mean starting point for occipital condyle screws was 6.17 mm lateral and 5.38 mm rostral to the medial O-C1 joint. Mean axial and sagittal trajectories were 7.98 degrees degrees and 6.71 degrees, degrees , respectively. The mean starting point for C1 screws was 16.11 mm lateral to the C1 anterior tubercle and 6.39 mm caudal to the medial O-C1 joint. Mean axial and sagittal trajectories were 10.97 degrees degrees and L 9.91 degrees , respectively. CONCLUSIONS: Endonasal OCF is technically and anatomically feasible. The application of this technique may allow for same-stage endonasal decompression and fixation, offering a minimally invasive alternative to current methods of fixation and advancing surgeons' ability to treat pathology of the craniovertebral junction. Next steps will focus on biomechanical testing.
引用
收藏
页码:E959 / E969
页数:11
相关论文
共 50 条
  • [31] Feasibility Study of the Three-Dimensional Flexible Endoscope in Endoscopic Submucosal Dissection: An ex vivo Animal Study
    Kikuchi, Daisuke
    Kaise, Mitsuru
    Nomura, Kosuke
    Toba, Takahito
    Kuribayashi, Yasutaka
    Tanaka, Masami
    Yamashita, Satoshi
    Furuhata, Tsukasa
    Matsui, Akira
    Mitani, Toshifumi
    Hoteya, Shu
    Iizuka, Toshiro
    DIGESTION, 2017, 95 (03) : 237 - 241
  • [32] Personalized Three-Dimensional Printed Anterior Titanium Plate to Treat Double-Column Acetabular Fractures: A Retrospective Case-Control Study
    Wu, Hai-yang
    Shao, Qi-peng
    Song, Cheng-jing
    Shang, Ran-ran
    Liu, Xi-ming
    Cai, Xian-hua
    ORTHOPAEDIC SURGERY, 2020, 12 (04) : 1212 - 1222
  • [33] Fracture of Standard Titanium Mandibular Reconstruction Plates and Preliminary Study of Three-Dimensional Printed Reconstruction Plates
    Almansoori, Akram Abdo
    Choung, Han-Wool
    Kim, Bongju
    Park, Joo-Young
    Kim, Soung-Min
    Lee, Jong-Ho
    JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2020, 78 (01) : 153 - 166
  • [34] A Feasibility Study on the Three-Dimensional Friction Stir Welding of Aluminum 5083-O Thin Plate
    Kim, Young-Gon
    Kim, In-Ju
    Kim, Young-Pyo
    Joo, Sung-Min
    MATERIALS TRANSACTIONS, 2016, 57 (06) : 988 - 994
  • [35] Three-Dimensional Printed Model-Assisted Screw Installation in Treating Posterior Atlantoaxial Internal Fixation (vol 8, pg 11026, 2018)
    Yang, Minyi
    Zhang, Nannan
    Shi, Haodong
    Li, Hui
    Liu, Shichang
    Song, Zongrang
    Shan, Lequn
    Wu, Qining
    Hao, Dingjun
    SCIENTIFIC REPORTS, 2019, 9 (1)
  • [36] The performance tests of three-dimensional printing titanium alloy craniomaxillofacial bone plate: A preliminary preclinical study
    Wei, Hongpu
    Xue, Xiaochen
    Yu, Jingshuang
    Jiang, Tengfei
    Li, Xiang
    Lin, Kaili
    Zhang, Lei
    Wang, Xudong
    JOURNAL OF DENTAL SCIENCES, 2023, 18 (04) : 1756 - 1764
  • [37] Three-dimensional finite element study of anterior transpedicular screw-artificial vertebral fixation in lower cervical spine
    Weidong Wu
    Peidong Sun
    Chun Chen
    Changfu Wu
    Jun Ouyang
    医用生物力学, 2013, 28(S1) (S1) : 125 - 126
  • [38] Three-dimensional v/s standard titanium miniplate fixation in the management of mandibular fractures - A randomized clinical study
    Sehgal, Saumya
    Ramanujam, Lalitha
    Prasad, Kavitha
    Krishnappa, Ranganath
    JOURNAL OF CRANIO-MAXILLOFACIAL SURGERY, 2014, 42 (07) : 1292 - 1299
  • [39] Three-dimensional-printed patient-specific Kirschner-wire guide for percutaneous fixation of undisplaced scaphoid fractures: a cadaveric study
    Salabi, Vincent
    Rigoulot, Guillaume
    Sautet, Alain
    Cambon-Binder, Adeline
    JOURNAL OF HAND SURGERY-EUROPEAN VOLUME, 2019, 44 (07) : 692 - 696
  • [40] Endonasal endoscopic resection of the odontoid process in a nonachondroplastic dwarf with juvenile rheumatoid arthritis:: feasibility of the approach and utility of the intraoperative Iso-C three-dimensional navigation
    Laufer, Ilya
    Greenfield, Jeffrey P.
    Anand, Vijay K.
    Haertl, Roger
    Schwartz, Theodore H.
    JOURNAL OF NEUROSURGERY-SPINE, 2008, 8 (04) : 376 - 380