Endoscopic Endonasal Occipitocervical Fixation with a Customized Three-Dimensional Printed Titanium Plate-Screw Construct: A Cadaveric Feasibility Study

被引:0
|
作者
Kaye, Joel [1 ]
Na, John [1 ]
Stephan, Katarina [1 ]
Bal, Ella [1 ]
Nebor, Ivanna [1 ]
Bucherl, Sean [2 ]
Nauman, Eric [2 ]
Nasser, Rani [1 ]
Virojanapa, Justin [1 ]
Andaluz, Norberto [1 ]
Forbes, Jonathan A. [1 ]
机构
[1] Univ Cincinnati, Coll Med, Dept Neurol Surg, Cincinnati, OH 45221 USA
[2] Univ Cincinnati, Coll Engn & Appl Sci, Dept Biomed Engn, Cincinnati, OH USA
关键词
Craniocervical junction; Endonasal; Occipitocervical fusion; Odontoidectomy; VENTRAL CRANIOCERVICAL JUNCTION; CRANIOVERTEBRAL JUNCTION; BIOMECHANICAL EVALUATION; RESECTION; PLACEMENT; STABILITY; EXPOSURE; C1-C2;
D O I
10.1016/j.wneu.2024.07.055
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
OBJECTIVE: To evaluate the feasibility of a novel method for occipitocervical fixation (OCF) through the endonasal corridor. METHODS: Thin-cut computed tomography scans were obtained for 5 cadaveric specimens. Image segmentation was used to reconstruct 3D models of each O-C1 joint complex. Using computer-aided design software, plates were custom-designed to span each O-C1 joint, sit flush onto the bony surface, and accommodate screws. The final models were 3D-printed in titanium. For implantation, specimens were held in pin-fixation and registered to neuronavigation. A rigid 0o endoscope was used for endonasal visualization. An inverted U-shaped nasopharyngeal flap was raised to expose the occipital condyles and C1. The plates were introduced and fixed with bone screws. Computed tomography scans were obtained to assess screw accuracy and proximity to critical neurovascular structures. Screw entry points and trajectories were recorded. RESULTS: Endonasal OCF was performed on 5 cadaveric specimens. The mean starting point for occipital condyle screws was 6.17 mm lateral and 5.38 mm rostral to the medial O-C1 joint. Mean axial and sagittal trajectories were 7.98 degrees degrees and 6.71 degrees, degrees , respectively. The mean starting point for C1 screws was 16.11 mm lateral to the C1 anterior tubercle and 6.39 mm caudal to the medial O-C1 joint. Mean axial and sagittal trajectories were 10.97 degrees degrees and L 9.91 degrees , respectively. CONCLUSIONS: Endonasal OCF is technically and anatomically feasible. The application of this technique may allow for same-stage endonasal decompression and fixation, offering a minimally invasive alternative to current methods of fixation and advancing surgeons' ability to treat pathology of the craniovertebral junction. Next steps will focus on biomechanical testing.
引用
收藏
页码:E959 / E969
页数:11
相关论文
共 50 条
  • [21] Three-dimensional (3D) printed endovascular simulation models: a feasibility study
    Mafeld, Sebastian
    Nesbitt, Craig
    McCaslin, James
    Bagnall, Alan
    Davey, Philip
    Bose, Pentop
    Williams, Rob
    ANNALS OF TRANSLATIONAL MEDICINE, 2017, 5 (03)
  • [22] Author Correction: Three-Dimensional Printed Model-Assisted Screw Installation in Treating Posterior Atlantoaxial Internal Fixation
    Minyi Yang
    Nannan Zhang
    Haodong Shi
    Hui Li
    Shichang Liu
    Zongrang Song
    Lequn Shan
    Qining Wu
    Dingjun Hao
    Scientific Reports, 9
  • [23] Feasibility and improvement of a three-dimensional printed navigation template for modified cortical bone trajectory screw placement in the lumbar spine
    Shi, Wenjie
    Aini, Mijiti
    Dang, Limin
    Kahaer, Alafate
    Zhou, Zhihao
    Wang, Yixi
    Maimaiti, Abulikemu
    Wang, Shuiquan
    Guo, Hailong
    Rexiti, Paerhati
    FRONTIERS IN SURGERY, 2022, 9
  • [24] Biomechanical stability of magnesium plate and screw fixation systems in LeFort I osteotomy: a three-dimensional finite element analysis
    Cho, Su-Min
    Yang, Byoung-Eun
    Kim, Won-Hyeon
    Park, Sang-Yoon
    On, Sung-Woon
    Lee, Jong-Ho
    Byun, Soo-Hwan
    MAXILLOFACIAL PLASTIC AND RECONSTRUCTIVE SURGERY, 2024, 46 (01)
  • [25] Robotic Surgical Approach to the Mesial Temporal Region: A Preliminary Three-Dimensional Cadaveric Study of Technical Feasibility
    Akbas, Ahmet
    Tugcu, Bekir
    Eksi, M. Sakir
    Erkan, Buruc
    Canbolat, Cagri
    Pamir, M. Necmettin
    Gungor, Abuzer
    WORLD NEUROSURGERY, 2020, 144 : E40 - E52
  • [26] Endoscopic Endonasal Approach for Clipping Anterior Communicating Artery Aneurysms From Cadaver Studies and Three-Dimensional Printed Models to a Clinical Case
    Qin, Kun
    Guo, Wenlong
    Zheng, Jiantao
    Tian, Ge
    Jiang, Hui
    Tang, Kai
    Shu, Hang
    Zhou, Dong
    Chen, Guangzhong
    JOURNAL OF CRANIOFACIAL SURGERY, 2021, 32 (08) : 2854 - 2858
  • [27] Navigated Percutaneous Lumbosacral Interbody Fusion A Feasibility Study With Three-Dimensional Surgical Simulation and Cadaveric Experiment
    Wang, Yu
    Le, Dang Q. S.
    Li, Haisheng
    Wang, Miao
    Bunger, Cody Eric
    SPINE, 2011, 36 (16) : E1105 - E1111
  • [28] Second Sacral Alar Screw Fixation: Anatomic Study of Three-Dimensional Computed Tomography and Case Report
    Xu, Yang
    Lin, Fei-Yue
    Lin, Xi
    Yin, Xiao-Ming
    WORLD NEUROSURGERY, 2019, 126 : E1542 - E1548
  • [29] Workload implications for clinic workflow with implementation of three-dimensional printed customized bolus for radiation therapy: A pilot study
    Ehler, Eric
    Sterling, David
    Dusenbery, Kathryn
    Lawrence, Jessica
    PLOS ONE, 2018, 13 (10):
  • [30] Three-Dimensional Printed Porous Titanium Screw with Bioactive Surface Modification for Bone-Tendon Healing: A Rabbit Animal Model
    Huang, Yu-Min
    Huang, Chih-Chieh
    Tsai, Pei-, I
    Yang, Kuo-Yi
    Huang, Shin-, I
    Shen, Hsin-Hsin
    Lai, Hong-Jen
    Huang, Shu-Wei
    Chen, San-Yuan
    Lin, Feng-Huei
    Chen, Chih-Yu
    INTERNATIONAL JOURNAL OF MOLECULAR SCIENCES, 2020, 21 (10)