Photoacoustic/ultrasound dual-modality imaging for marker clip localization in neoadjuvant chemotherapy of breast cancer

被引:0
|
作者
Deng, Handi [1 ,2 ,3 ]
Bai, Yizhou [2 ,3 ,4 ]
Xiang, Jiaxuan [5 ]
Li, Zhaoyue [4 ]
Zhao, Peiliang [4 ]
Shi, Yawen [1 ,2 ,3 ]
Fu, Wubing [5 ]
Chen, Yuwen [1 ]
Fu, Minggang [6 ]
Ma, Cheng [1 ,2 ,3 ]
Luo, Bin [2 ,3 ,4 ]
机构
[1] Tsinghua Univ, Beijing Natl Res Ctr Informat Sci & Technol, Dept Elect Engn, Beijing, Peoples R China
[2] Tsinghua Univ, Inst Precis Healthcare, Beijing, Peoples R China
[3] Tsinghua Univ, Inst Intelligent Healthcare, Beijing, Peoples R China
[4] Tsinghua Univ, Beijing Tsinghua Changgung Hosp, Sch Clin Med, Beijing, Peoples R China
[5] TsingPAI Technol Co Ltd, Beijing, Peoples R China
[6] Jinan Univ, Dept Thyroid & Galactophore Surg, Zhuhai Hosp, Zhuhai, Peoples R China
基金
中国国家自然科学基金;
关键词
PA/US dual-modality imaging; marker clip; neoadjuvant chemotherapy; tumor localization;
D O I
10.1117/1.JBO.29.S1.S11525
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Significance: To ensure precise tumor localization and subsequent pathological examination, a metal marker clip (MC) is placed within the tumor or lymph node prior to neoadjuvant chemotherapy for breast cancer. However, as tumors decrease in size following treatment, detecting the MC using ultrasound imaging becomes challenging in some patients. Consequently, a mammogram is often required to pinpoint the MC, resulting in additional radiation exposure, time expenditure, and increased costs. Dual-modality imaging, combining photoacoustic (PA) and ultrasound (US), offers a promising solution to this issue. Aim: Our objective is to localize the MC without radiation exposure using PA/US dual-modality imaging. Approach: A PA/US dual-modality imaging system was developed. Utilizing this system, both phantom and clinical experiments were conducted to demonstrate that PA/US dual-modality imaging can effectively localize the MC. Results: The PA/US dual-modality imaging can identify and localize the MC. In clinical trials encompassing four patients and five MCs, the recognition rate was similar to 80%. Three experiments to verify the accuracy of marker position recognition were successful. Conclusions: We effectively localized the MC in real time using PA/US dualmodality imaging. Unlike other techniques, the new method enables surgeons to pinpoint nodules both preoperatively and intraoperatively. In addition, it boasts nonradioactivity and is comparatively cost-effective.
引用
收藏
页数:14
相关论文
共 50 条
  • [31] Dual-modality imaging with a ultrasound-gamma device for oncology
    Polito, C.
    Pellegrini, R.
    Cinti, M. N.
    De Vincentis, G.
    Lo Meo, S.
    Fabbri, A.
    Bennati, P.
    Cencelli, V. Orsolini
    Pani, R.
    RADIATION PHYSICS AND CHEMISTRY, 2018, 147 : 77 - 84
  • [32] Organic nanoparticle-doped microdroplets as dual-modality contrast agents for ultrasound microvascular flow and photoacoustic imaging
    Xu, Yu
    Sun, Guoyun
    Middha, Eshu
    Liu, Yu-Hang
    Chan, Kim Chuan
    Liu, Bin
    Chen, Chia-Hung
    Thakor, Nitish V.
    SCIENTIFIC REPORTS, 2020, 10 (01)
  • [33] Organic nanoparticle-doped microdroplets as dual-modality contrast agents for ultrasound microvascular flow and photoacoustic imaging
    Yu Xu
    Guoyun Sun
    Eshu Middha
    Yu-Hang Liu
    Kim Chuan Chan
    Bin Liu
    Chia-Hung Chen
    Nitish V. Thakor
    Scientific Reports, 10
  • [34] A Dual-Modality Photoacoustic and Ultrasound Imaging System for Noninvasive Sentinel Lymph Node Detection: Preliminary Clinical Results
    Erpelding, Todd N.
    Garcia-Uribe, Alejandro
    Krumholz, Arie
    Ke, Haixin
    Maslov, Konstantin
    Appleton, Catherine
    Margenthaler, Julie
    Wang, Lihong V.
    PHOTONS PLUS ULTRASOUND: IMAGING AND SENSING 2014, 2014, 8943
  • [35] Optical and photoacoustic dual-modality imaging guided synergistic photodynamic/photothermal therapies
    Yan, Xuefeng
    Hu, Hao
    Lin, Jing
    Jin, Albert J.
    Niu, Gang
    Zhang, Shaoliang
    Huang, Peng
    Shen, Baozhong
    Chen, Xiaoyuan
    NANOSCALE, 2015, 7 (06) : 2520 - 2526
  • [36] A real-time photoacoustic and ultrasound dual-modality imaging system facilitated with GPU and code parallel optimization
    Yuan, Jie
    Xu, Guan
    Yu, Yao
    Zhou, Yu
    Carson, Paul L.
    Wang, Xueding
    Liu, Xiaojun
    PHOTONS PLUS ULTRASOUND: IMAGING AND SENSING 2014, 2014, 8943
  • [37] Effect of a Gel Retainment Dam on Automated Ultrasound Coverage in a Dual-Modality Breast Imaging System
    Li, Jie
    Goodsitt, Mitchell M.
    Padilla, Frederic
    Fowlkes, J. Brian
    Hooi, Fong Ming
    Lashbrook, Christine R.
    Thomenius, Kai E.
    Carson, Paul L.
    JOURNAL OF ULTRASOUND IN MEDICINE, 2010, 29 (07) : 1075 - 1081
  • [38] Automated ultrasound scanning on a dual-modality breast imaging system - Coverage and motion issues and solutions
    Sinha, Sumedha P.
    Goodsitt, Mitchell M.
    Roubidoux, Marilyn A.
    Booi, Rebecca C.
    LeCarpentier, Gerald L.
    Lashbrook, Christine R.
    Thomenius, Kai E.
    Chalek, Carl L.
    Carson, Paul L.
    JOURNAL OF ULTRASOUND IN MEDICINE, 2007, 26 (05) : 645 - 655
  • [39] DUAL-MODALITY ENDOSCOPIC IMAGING OF CANCER IN MOUSE COLON
    Keenan, Molly R.
    Leung, Sarah J.
    Rice, Photini
    Wall, R. Andrew
    Barton, Jennifer K.
    LASERS IN SURGERY AND MEDICINE, 2014, 46 : 26 - 26
  • [40] PHOTOACOUSTIC AND ULTROSOUND DUAL-MODALITY ENDOSCOPIC IMAGING BASED ON ALN PMUT ARRAY
    Cai, Junxiang
    Wang, Yiyun
    Lou, Liang
    Zhang, Songsong
    Gu, Yuandong
    Gao, Fei
    Wu, Tao
    2022 IEEE 35TH INTERNATIONAL CONFERENCE ON MICRO ELECTRO MECHANICAL SYSTEMS CONFERENCE (MEMS), 2022, : 412 - 415