A Radiological Comparison of Robotic-Assisted Versus Manual Techniques in Total Hip Arthroplasty

被引:0
|
作者
Annapareddy, Adarsh [1 ]
Mulpur, Praharsha [1 ]
Jayakumar, Tarun [1 ]
Shinde, Chethan [1 ]
Prasad, Vemaganti Badri Narayana [1 ]
Reddy, A. V. Gurava [1 ]
机构
[1] KIMS Sunshine Hosp, Sunshine Bone & Joint Inst, Hyderabad, India
关键词
Total hip arthroplasty; Robotic; Radiological outcomes; Robotic vs. conventional; Accuracy; Radiological measurement; Bone Ninja; ACETABULAR COMPONENT; CUP; DISLOCATION; WEAR;
D O I
10.1007/s43465-024-01232-1
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose This study investigates the radiological outcomes of robotic-assisted total hip arthroplasty (RATHA) compared to manual total hip arthroplasty (mTHA), addressing the ongoing debate on the effectiveness of RATHA in achieving superior implant positioning accuracy. Methods A prospective cohort of 212 patients (103 robotic, 109 manual) underwent THA and were evaluated for postoperative radiological outcomes, focusing on the inclination and anteversion angles of the acetabular cup. Outlier prevalence was assessed based on angles outside the defined Lewinnek safe zones. All post-operative measurements were made using the BoneNinja application. Results High inter-observer and intra-observer reliabilities were observed, validating the measurement accuracy. The mean anteversion and inclination angles in the RATHA cohort were 40.5 +/- 1.5 and 24.5 +/- 3.1 degrees respectively; and the mTHA cohort were 42.1 +/- 4.9 and 24.9 +/- 4.5 degrees. There was a statistically significant difference in inclination angles between the two cohorts whereas the anteversion angles showed no difference. Majority of the conventional THRs (N = 72, 55.4%) were placed outside the safe zone for anteversion. The inclination angles revealed a highly significant difference between the cohorts (p < 0.0001), with all the robotic THRs (N = 121, 100%) being placed within the safe zone for inclination, whereas only 70% (N = 91) of the conventional THRs were within the safe zone. 97.5% of RA-THRs were within 3 degrees of the proposed plan, demonstrating high accuracy. Conclusion RATHA significantly outperforms MTHA in radiological accuracy, achieving precise acetabular cup positioning with minimal outliers. These results advocate for RATHA's adoption in THA to enhance outcome predictability and affirm its reliability and safety over manual methods.
引用
收藏
页码:1423 / 1430
页数:8
相关论文
共 50 条
  • [41] No Difference in Range of Motion, Components, or Complications Following Conversion of Robotic-Assisted Total Knee Arthroplasty Compared to Manual TKA After Undergoing Manual or Robotic-Assisted Unicompartmental Knee Arthroplasty
    Lachance, Andrew D.
    Edelstein, Alexander
    Stilwell, Mason
    Lutton, Jeffrey
    ARTHROPLASTY TODAY, 2023, 24
  • [42] Robotic arm-assisted versus manual total hip arthroplasty A PROPENSITY SCORE MATCHED COHORT STUDY
    Clement, N. D.
    Gaston, P.
    Bell, A.
    Simpson, P.
    Macpherson, G.
    Hamilton, D. F.
    Patton, J. T.
    BONE & JOINT RESEARCH, 2021, 10 (01): : 22 - 30
  • [43] Robotic arm-assisted versus manual total hip arthroplasty A SYSTEMATIC REVIEW AND META-ANALYSIS
    Ng, N.
    Gaston, P.
    Simpson, P. M.
    Macpherson, G. J.
    Patton, J. T.
    Clement, N. D.
    BONE & JOINT JOURNAL, 2021, 103B (06): : 1009 - 1020
  • [44] Conversion of Patellofemoral Arthroplasty to Robotic-Assisted Total Knee Arthroplasty
    Lachance, Andrew D.
    Steika, Roman
    Lutton, Jeffrey
    Austin, David
    ARTHROPLASTY TODAY, 2023, 23
  • [45] The Cost-Effectiveness of Robotic-Assisted Versus Manual Total Knee Arthroplasty: A Markov Model-Based Evaluation
    Rajan, Prashant V. V.
    Khlopas, Anton
    Klika, Alison
    Molloy, Robert
    Krebs, Viktor
    Piuzzi, Nicolas S. S.
    JOURNAL OF THE AMERICAN ACADEMY OF ORTHOPAEDIC SURGEONS, 2022, 30 (04) : 168 - 176
  • [46] Contemporary analysis of the learning curve for robotic-assisted total hip arthroplasty emerging technologies
    Hecht, Christian J.
    Porto, Joshua R.
    Sanghvi, Parshva A.
    Homma, Yasuhiro
    Sculco, Peter K.
    Kamath, Atul F.
    JOURNAL OF ROBOTIC SURGERY, 2024, 18 (01)
  • [47] Postoperative outcomes and trends in computer-navigated and robotic-assisted total hip arthroplasty
    Piple, Amit S.
    Wang, Jennifer C.
    Hill, William
    Chen, Matthew S.
    Gettleman, Brandon S.
    Liu, Kevin C.
    Heckmann, Nathanael D.
    Christ, Alexander B.
    HIP INTERNATIONAL, 2024, 34 (05) : 569 - 577
  • [48] Stem anteversion is not affected by proximal femur geometry in robotic-assisted total hip arthroplasty
    Marcovigi, Andrea
    Grandi, Gianluca
    Bianchi, Luca
    Zambianchi, Francesco
    Pavesi, Marco
    Catani, Fabio
    ARTHROPLASTY, 2024, 6 (01)
  • [49] Robotic-assisted total knee arthroplasty is associated with the use of thinner polyethylene liners compared to navigation-guided and manual techniques
    Cheng, Ryan
    Kim, Billy
    Taylor, Walter L.
    Westrich, Geoffrey H.
    Shen, Tony S.
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2024, 32 (09) : 2290 - 2296
  • [50] The Current Role of Robotic-assisted Total Knee Arthroplasty
    Rodriguez-Merchan, E. Carlos
    ARCHIVES OF BONE AND JOINT SURGERY-ABJS, 2022, 10 (12): : 989 - 991