Robotic-assisted total knee arthroplasty is associated with the use of thinner polyethylene liners compared to navigation-guided and manual techniques

被引:1
|
作者
Cheng, Ryan [1 ]
Kim, Billy [1 ]
Taylor, Walter L. [1 ]
Westrich, Geoffrey H. [1 ]
Shen, Tony S. [1 ]
机构
[1] Hosp Special Surg, Dept Adult Reconstruct & Joint Replacement, New York, NY 10021 USA
关键词
bony resection; intraoperative technology; polyethylene liners; primary total knee arthroplasty; robotics;
D O I
10.1002/ksa.12228
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose: The purpose of this study was to examine the effects of intraoperative technology use on the rate of using polyethylene liners 15 mm or greater during primary total knee arthroplasty (TKA). Methods: There were 103,295 implants from 16,386 primary unilateral TKAs performed on 14,253 patients at a single institution between 1 January 2018, and 30 June 2022, included in the current study. Robotic assistance and navigation guidance were used in 1274 (8%) and 8345 (51%) procedures, respectively. The remaining 6767 TKAs (41%) were performed manually. Polyethylene liners were manually identified and further subcategorised by implant thickness. Patients who underwent robotic-assisted TKA were younger (p < 0.001) and more likely to be male (p < 0.001) compared to patients who underwent navigation-guided or manual TKAs. Results: Average polyethylene liner thickness was similar between groups (10.5 +/- 1.5 mm for robotic-assisted TKAs, 10.9 +/- 1.8 mm for navigation-guided TKAs and 10.8 +/- 1.8 mm for manual TKAs). The proportions of polyethylene liners 15 mm or greater used were 4.9%, 3.8% and 1.9% for navigation-guided, manual and robotic-assisted procedures, respectively (p < 0.001). Multivariate regression analyses demonstrated that navigation-guided (odds ratio [OR]: 2.6, 95% confidence Interval [CI]: [1.75-4.07], p < 0.001) and manual (OR: 2.0, 95% CI: [1.34-3.20], p = 0.001) procedures were associated with an increased use of polyethylene liners 15 mm or greater. Conclusion: Robotic-assisted TKA was associated with a lower proportion of polyethylene liners 15 mm or greater used compared to navigation-guided and manual TKA. These findings suggest that robotic assistance can reduce human error via a more precise cutting system, limit over-resection of the tibia and flexion-extension gap mismatch and ultimately allow for more appropriately sized implants.
引用
收藏
页码:2290 / 2296
页数:7
相关论文
共 50 条
  • [1] Robotic-assisted total knee arthroplasty reduces postoperative complications and length of stay without increased cost compared to navigation-guided techniques: A national analysis
    Maman, David
    Laver, Lior
    Becker, Roland
    Mahamid, Assil
    Berkovich, Yaron
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2024,
  • [2] Robotic-assisted total knee arthroplasty improves accuracy and precision compared to conventional techniques
    Deckey, D. G.
    Rosenow, C. S.
    Verhey, J. T.
    Brinkman, J. C.
    Mayfield, C. K.
    Clarke, H. D.
    Bingham, J. S.
    BONE & JOINT JOURNAL, 2021, 103B (06): : 74 - 80
  • [3] No Difference in Range of Motion, Components, or Complications Following Conversion of Robotic-Assisted Total Knee Arthroplasty Compared to Manual TKA After Undergoing Manual or Robotic-Assisted Unicompartmental Knee Arthroplasty
    Lachance, Andrew D.
    Edelstein, Alexander
    Stilwell, Mason
    Lutton, Jeffrey
    ARTHROPLASTY TODAY, 2023, 24
  • [4] Robotic-assisted total knee arthroplasty improved component alignment in the coronal plane compared with navigation-assisted total knee arthroplasty: a comparative study
    Yasuyuki Omichi
    Daisuke Hamada
    Keizo Wada
    Yasuaki Tamaki
    Shota Shigekiyo
    Koichi Sairyo
    Journal of Robotic Surgery, 2023, 17 : 2831 - 2839
  • [5] Robotic-assisted total knee arthroplasty improved component alignment in the coronal plane compared with navigation-assisted total knee arthroplasty: a comparative study
    Omichi, Yasuyuki
    Hamada, Daisuke
    Wada, Keizo
    Tamaki, Yasuaki
    Shigekiyo, Shota
    Sairyo, Koichi
    JOURNAL OF ROBOTIC SURGERY, 2023, 17 (06) : 2831 - 2839
  • [6] The Use of Navigation or Robotic-Assisted Technology in Total Knee Arthroplasty Does Not Reduce Postoperative Pain
    Zak, Stephen Gerard
    Yeroushalmi, David
    Tang, Alex
    Meftah, Morteza
    Schnaser, Erik
    Schwarzkopf, Ran
    JOURNAL OF KNEE SURGERY, 2023, 36 (04) : 439 - 444
  • [7] The Reliability of Navigation-guided Gap Technique in Total Knee Arthroplasty
    Han, Seung-Beom
    Nha, Kyung-Wook
    Yoon, Jung-Ro
    Lee, Dae-Hee
    Chae, In-Jung
    ORTHOPEDICS, 2008, 31 (10) : 40 - 44
  • [8] Lengths of Stay and Discharge Dispositions after Total Knee Arthroplasty: A Comparison of Robotic-Assisted and Manual Techniques
    Archer, Allison
    Salem, Hytham S.
    Coppolecchia, Andrea
    Mont, Michael A.
    JOURNAL OF KNEE SURGERY, 2023, 36 (04) : 404 - 410
  • [9] Comparison of robotic-assisted and conventional manual implantation of a primary total knee arthroplasty
    Park, Sang Eun
    Lee, Chun Taek
    JOURNAL OF ARTHROPLASTY, 2007, 22 (07): : 1054 - 1059
  • [10] Minimal Clinically Important Difference in Robotic-Assisted Total Knee Arthroplasty Versus Standard Manual Total Knee Arthroplasty
    Shaw, Jonathan H.
    Lindsay-Rivera, Kevin G.
    Buckley, Patrick J.
    Weir, Robb M.
    Banka, Trevor R.
    Davis, Jason J.
    JOURNAL OF ARTHROPLASTY, 2021, 36 (07): : S233 - S241