Examination of methods to separate overlapping metabolites at 7T

被引:0
|
作者
Bell, Tiffany K. [1 ,2 ,3 ]
Goerzen, Dana [4 ]
Near, Jamie [5 ,6 ]
Harris, Ashley D. [1 ,2 ,3 ]
机构
[1] Univ Calgary, Dept Radiol, Calgary, AB, Canada
[2] Univ Calgary, Hotchkiss Brain Inst, Calgary, AB, Canada
[3] Univ Calgary, Alberta Childrens Hosp, Res Inst, Calgary, AB, Canada
[4] Cornell Univ, Weill Cornell Med, New York, NY USA
[5] Sunnybrook Res Inst, Phys Studies Res Platform, Toronto, ON, Canada
[6] Univ Toronto, Dept Med Biophys, Toronto, ON, Canada
基金
加拿大自然科学与工程研究理事会; 加拿大健康研究院;
关键词
7; T; brain; high field; magnetic resonance spectroscopy; semi-LASER; STEAM; MAGNETIC-RESONANCE SPECTROSCOPY; SHORT-ECHO; H-1; MRS; BRAIN; REPEATABILITY; TIME;
D O I
10.1002/mrm.30293
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PurposeNeurochemicals of interest quantified by MRS are often composites of overlapping signals. At higher field strengths (i.e., 7T), there is better separation of these signals. As the availability of higher field strengths is increasing, it is important to re-evaluate the separability of overlapping metabolite signals.MethodsThis study compares the ability of stimulated echo acquisition mode (STEAM-8; TE = 8 ms), short-TE semi-LASER (sLASER-34; TE = 34 ms), and long-TE semi-LASER (sLASER-105; TE = 105 ms) acquisitions to separate the commonly acquired neurochemicals at 7T (Glx, consisting of glutamate and glutamine; total N-acetyl aspartate, consisting of N-acetyl aspartate and N-acetylaspartylglutamate; total creatine, consisting of creatine and phosphocreatine; and total choline, consisting of choline, phosphocholine, and glycerophosphocholine).ResultssLASER-34 produced the lowest fit errors for most neurochemicals; however, STEAM-8 had better within-subject reproducibility and required fewer subjects to detect a change between groups. However, this is dependent on the neurochemical of interest.ConclusionWe recommend short-TE STEAM for separation of most standard neurochemicals at 7T over short-TE or long-TE sLASER.
引用
收藏
页数:11
相关论文
共 50 条
  • [31] 7T SPECTROSCOPIC IMAGING FOR NEOCORTICAL EPILEPSY
    Pan, Jullie W.
    Avdievich, N. I.
    Spencer, D. D.
    Hetherington, H. P.
    Spencer, S. S.
    EPILEPSIA, 2009, 50 : 443 - 443
  • [32] Diffusion Tensor Imaging and Fibertracking at 7T
    Sammet, S.
    Irfanoglu, O.
    Koch, R.
    Schmalbrock, P.
    Choi, S.
    Machiraju, R.
    Yuh, W.
    Knopp, M.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2010, 194 (05)
  • [33] Spin echo based cardiac diffusion imaging at 7T: An ex vivo study of the porcine heart at 7T and 3T
    Lohr, David
    Terekhov, Maxim
    Weng, Andreas Max
    Schroeder, Anja
    Walles, Heike
    Schreiber, Laura Maria
    PLOS ONE, 2019, 14 (03):
  • [34] A hybrid hierarchical strategy for registration of 7T TOF-MRI to 7T PC-MRI intracranial vessel data
    Spitz, Lena
    Gaidzik, Franziska
    Stucht, Daniel
    Mattern, Hendrik
    Preim, Bernhard
    Saalfeld, Sylvia
    INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2023, 18 (05) : 837 - 844
  • [35] A hybrid hierarchical strategy for registration of 7T TOF-MRI to 7T PC-MRI intracranial vessel data
    Lena Spitz
    Franziska Gaidzik
    Daniel Stucht
    Hendrik Mattern
    Bernhard Preim
    Sylvia Saalfeld
    International Journal of Computer Assisted Radiology and Surgery, 2023, 18 : 837 - 844
  • [36] 7T MRI Loop Antenna for Carotid Imaging
    Hinge, Lars
    Mortensen, Nicolai
    Zhurbenko, Vitaliy
    Boer, Vincent O.
    Wang, Wenjun
    2020 50TH EUROPEAN MICROWAVE CONFERENCE (EUMC), 2020,
  • [37] Sharpness in motion corrected quantitative imaging at 7T
    Bazin, Pierre-Louis
    Nijsse, Hannah E.
    van der Zwaag, Wietske
    Gallichan, Daniel
    Alkemade, Anneke
    Vos, Frans M.
    Forstmann, Birte U.
    Caan, Matthan W. A.
    NEUROIMAGE, 2020, 222
  • [38] Classification of mouth movements using 7T fMRI
    Bleichner, M. G.
    Jansma, J. M.
    Salari, E.
    Freudenburg, Z. V.
    Raemaekers, M.
    Ramsey, N. F.
    JOURNAL OF NEURAL ENGINEERING, 2015, 12 (06)
  • [39] Anesthesia and monitoring for FMRI experiments at 7T in rats
    Elbel, GK
    Kalisch, R
    Schadrack, J
    Droese, DG
    Hipp, RF
    Auer, DP
    ANESTHESIA AND ANALGESIA, 2000, 90 (02):
  • [40] 7T MRI Loop Antenna for Carotid Imaging
    Hinge, Lars
    Mortensen, Nicolai
    Zhurbenko, Vitaliy
    Boer, Vincent O.
    Wang, Wenjun
    2020 50TH EUROPEAN MICROWAVE CONFERENCE (EUMC), 2020, : 1007 - 1010