Examination of methods to separate overlapping metabolites at 7T

被引:0
|
作者
Bell, Tiffany K. [1 ,2 ,3 ]
Goerzen, Dana [4 ]
Near, Jamie [5 ,6 ]
Harris, Ashley D. [1 ,2 ,3 ]
机构
[1] Univ Calgary, Dept Radiol, Calgary, AB, Canada
[2] Univ Calgary, Hotchkiss Brain Inst, Calgary, AB, Canada
[3] Univ Calgary, Alberta Childrens Hosp, Res Inst, Calgary, AB, Canada
[4] Cornell Univ, Weill Cornell Med, New York, NY USA
[5] Sunnybrook Res Inst, Phys Studies Res Platform, Toronto, ON, Canada
[6] Univ Toronto, Dept Med Biophys, Toronto, ON, Canada
基金
加拿大自然科学与工程研究理事会; 加拿大健康研究院;
关键词
7; T; brain; high field; magnetic resonance spectroscopy; semi-LASER; STEAM; MAGNETIC-RESONANCE SPECTROSCOPY; SHORT-ECHO; H-1; MRS; BRAIN; REPEATABILITY; TIME;
D O I
10.1002/mrm.30293
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PurposeNeurochemicals of interest quantified by MRS are often composites of overlapping signals. At higher field strengths (i.e., 7T), there is better separation of these signals. As the availability of higher field strengths is increasing, it is important to re-evaluate the separability of overlapping metabolite signals.MethodsThis study compares the ability of stimulated echo acquisition mode (STEAM-8; TE = 8 ms), short-TE semi-LASER (sLASER-34; TE = 34 ms), and long-TE semi-LASER (sLASER-105; TE = 105 ms) acquisitions to separate the commonly acquired neurochemicals at 7T (Glx, consisting of glutamate and glutamine; total N-acetyl aspartate, consisting of N-acetyl aspartate and N-acetylaspartylglutamate; total creatine, consisting of creatine and phosphocreatine; and total choline, consisting of choline, phosphocholine, and glycerophosphocholine).ResultssLASER-34 produced the lowest fit errors for most neurochemicals; however, STEAM-8 had better within-subject reproducibility and required fewer subjects to detect a change between groups. However, this is dependent on the neurochemical of interest.ConclusionWe recommend short-TE STEAM for separation of most standard neurochemicals at 7T over short-TE or long-TE sLASER.
引用
收藏
页数:11
相关论文
共 50 条
  • [21] Cerebrovascular Imaging at 7T: A New High
    Ozutemiz, Can
    SEMINARS IN ROENTGENOLOGY, 2024, 59 (02) : 148 - 156
  • [22] A 7T Security Oriented SRAM Bitcell
    Giterman, Robert
    Keren, Osnat
    Fish, Alexander
    IEEE TRANSACTIONS ON CIRCUITS AND SYSTEMS II-EXPRESS BRIEFS, 2019, 66 (08) : 1396 - 1400
  • [24] The technological future of 7T MRI hardware
    Webb, A. G.
    Van de Moortele, P. F.
    NMR IN BIOMEDICINE, 2016, 29 (09) : 1305 - 1315
  • [25] Magnetic Resonance Safety in the 7T Environment
    Fagan, Andrew J.
    Amrami, Kimberly K.
    Welker, Kirk M.
    Frick, Matthew A.
    Felmlee, Joel P.
    Watson, Robert E., Jr.
    MAGNETIC RESONANCE IMAGING CLINICS OF NORTH AMERICA, 2020, 28 (04) : 573 - +
  • [26] HIGHFIELD MRI: HUMAN APPLICATIONS AT 7T
    Speck, O.
    EPILEPSIA, 2009, 50 : 21 - 21
  • [27] 7T SRAM based Memory Cell
    Sharif, Kazi Fatima
    Islam, Riazul
    Haque, Mahbubul
    Keka, Marzia Akhter
    Biswas, Satyendra N.
    2017 INTERNATIONAL CONFERENCE ON INNOVATIVE MECHANISMS FOR INDUSTRY APPLICATIONS (ICIMIA), 2017, : 191 - 194
  • [28] METHODS FOR THE EXAMINATION OF URINARY METABOLITES OF TRYPTOPHAN
    DALGLIESH, CE
    BIOCHEMICAL JOURNAL, 1952, 51 (03) : R28 - R28
  • [29] Giant Intracranial Aneurysms at 7T MRI
    Matsushige, T.
    Chen, B.
    Ringelstein, A.
    Umutlu, L.
    Forsting, M.
    Quick, H. H.
    Sure, U.
    Wrede, K. H.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2016, 37 (04) : 636 - 641
  • [30] A DC QUADRUPOLE 7T TEST FACILITY
    DEREUVER, JL
    STEFFENS, HA
    VANDEKLUNDERT, LJM
    JOURNAL DE PHYSIQUE, 1984, 45 (NC-1): : 813 - 816