Examination of methods to separate overlapping metabolites at 7T

被引:0
|
作者
Bell, Tiffany K. [1 ,2 ,3 ]
Goerzen, Dana [4 ]
Near, Jamie [5 ,6 ]
Harris, Ashley D. [1 ,2 ,3 ]
机构
[1] Univ Calgary, Dept Radiol, Calgary, AB, Canada
[2] Univ Calgary, Hotchkiss Brain Inst, Calgary, AB, Canada
[3] Univ Calgary, Alberta Childrens Hosp, Res Inst, Calgary, AB, Canada
[4] Cornell Univ, Weill Cornell Med, New York, NY USA
[5] Sunnybrook Res Inst, Phys Studies Res Platform, Toronto, ON, Canada
[6] Univ Toronto, Dept Med Biophys, Toronto, ON, Canada
基金
加拿大自然科学与工程研究理事会; 加拿大健康研究院;
关键词
7; T; brain; high field; magnetic resonance spectroscopy; semi-LASER; STEAM; MAGNETIC-RESONANCE SPECTROSCOPY; SHORT-ECHO; H-1; MRS; BRAIN; REPEATABILITY; TIME;
D O I
10.1002/mrm.30293
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PurposeNeurochemicals of interest quantified by MRS are often composites of overlapping signals. At higher field strengths (i.e., 7T), there is better separation of these signals. As the availability of higher field strengths is increasing, it is important to re-evaluate the separability of overlapping metabolite signals.MethodsThis study compares the ability of stimulated echo acquisition mode (STEAM-8; TE = 8 ms), short-TE semi-LASER (sLASER-34; TE = 34 ms), and long-TE semi-LASER (sLASER-105; TE = 105 ms) acquisitions to separate the commonly acquired neurochemicals at 7T (Glx, consisting of glutamate and glutamine; total N-acetyl aspartate, consisting of N-acetyl aspartate and N-acetylaspartylglutamate; total creatine, consisting of creatine and phosphocreatine; and total choline, consisting of choline, phosphocholine, and glycerophosphocholine).ResultssLASER-34 produced the lowest fit errors for most neurochemicals; however, STEAM-8 had better within-subject reproducibility and required fewer subjects to detect a change between groups. However, this is dependent on the neurochemical of interest.ConclusionWe recommend short-TE STEAM for separation of most standard neurochemicals at 7T over short-TE or long-TE sLASER.
引用
收藏
页数:11
相关论文
共 50 条
  • [1] Examination of methods to separate overlapping metabolites at 7T
    Bell, Tiffany K.
    Goerzen, Dana
    Near, Jamie
    Harris, Ashley D.
    MAGNETIC RESONANCE IN MEDICINE, 2025, 93 (02) : 470 - 480
  • [2] Relaxation Times of Skeletal Muscle Metabolites at 7T
    Wang, Ligong
    Salibi, Nouha
    Wu, Yan
    Schweitzer, Mark E.
    Regatte, Ravinder R.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2009, 29 (06) : 1457 - 1464
  • [3] 7T MRSafety
    Fagan, Andrew J.
    Bitz, Andreas K.
    Bjorkman-Burtscher, Isabella M.
    Collins, Christopher M.
    Kimbrell, Vera
    Raaijmakers, Alexander J. E.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2021, 53 (02) : 333 - 346
  • [4] Predicting performance in attention by measuring key metabolites in the PCC with 7T MRS
    Collee, M.
    Rajkumar, R.
    Farrher, E.
    Hagen, J.
    Ramkiran, S.
    Schnellbaecher, G. J.
    Khudeish, N.
    Shah, N. J.
    Veselinovic, T.
    Neuner, I.
    SCIENTIFIC REPORTS, 2024, 14 (01):
  • [5] Assessment of Sensations Experienced by Subjects during MR Imaging Examination at 7T
    Uwano, Ikuko
    Metki, Tsuyoshi
    Sendai, Fusako
    Yoshida, Ryoko
    Kudo, Kohsuke
    Yamashita, Fumio
    Higuchi, Satomi
    Ito, Kenji
    Harada, Taisuke
    Goodwin, Jonathan
    Ogawa, Akira
    Sasaki, Makoto
    MAGNETIC RESONANCE IN MEDICAL SCIENCES, 2015, 14 (01) : 35 - 41
  • [6] The Case of 7T: Clinical Insights on the Intronic 7T Variant in the CFTR Gene
    Huang, R. L.
    Albon, D. P.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2024, 209
  • [7] Diffusion-weighted chemical shift imaging of human brain metabolites at 7T
    Ercan, Ayse Ece
    Techawiboonwong, Aranee
    Versluis, Maarten J.
    Webb, Andrew G.
    Ronen, Itamar
    MAGNETIC RESONANCE IN MEDICINE, 2015, 73 (06) : 2053 - 2061
  • [8] 7T Imaging of the Wrist
    Friedrich, Klaus M.
    Komorowski, Arkadiusz
    Trattnig, Siegfried
    SEMINARS IN MUSCULOSKELETAL RADIOLOGY, 2012, 16 (02) : 88 - 92
  • [9] From the Tuning Fork to 7T MRT - The Use of objective Methods in Audiology
    Hoppe, Ulrich
    Hey, Matthias
    ZEITSCHRIFT FUR MEDIZINISCHE PHYSIK, 2021, 31 (03): : 235 - 236
  • [10] 7T Epilepsy Task Force Consensus Recommendations on the Use of 7T MRI in Clinical Practice
    Opheim, Giske
    van der Kolk, Anja
    Bloch, Karin Markenroth
    Colon, Albert J.
    Davis, Kathryn A.
    Henry, Thomas R.
    Jansen, Jacobus F. A.
    Jones, Stephen E.
    Pan, Jullie W.
    Rossler, Karl
    Stein, Joel M.
    Strandberg, Maria C.
    Trattnig, Siegfried
    de Moortele, Pierre-Francois Van
    Vargas, Maria Isabel
    Wang, Irene
    Bartolomei, Fabrice
    Bernasconi, Neda
    Bernasconi, Andrea
    Bernhardt, Boris
    Bjorkman-Burtscher, Isabella
    Cosottini, Mirco
    Das, Sandhitsu R.
    Hertz-Pannier, Lucie
    Inati, Sara
    Jurkiewicz, Michael T.
    Khan, Ali R.
    Liang, Shuli
    Ma, Ruoyun Emily
    Mukundan, Srinivasan
    Pardoe, Heath
    Pinborg, Lars H.
    Polimeni, Jonathan R.
    Ranjeva, Jean-Philippe
    Steijvers, Esther
    Stufflebeam, Steven
    Veersema, Tim J.
    Vignaud, Alexandre
    Voets, Natalie
    Vulliemoz, Serge
    Wiggins, Christopher J.
    Xue, Rong
    Guerrini, Renzo