The introduction of a sound reduction bundle in the intensive care unit and its impact on sound levels and patients

被引:0
|
作者
Tronstad, Oystein [1 ,2 ,3 ]
Patterson, Sue [1 ,4 ]
Zangerl, Barbara [1 ]
Flaws, Dylan [1 ,5 ,6 ]
Holdsworth, Robert [1 ]
Irvine, Lacey [1 ]
Yerkovich, Stephanie [7 ,8 ]
Pearse, India [1 ]
Fraser, John F. [1 ,2 ,9 ]
机构
[1] Prince Charles Hosp, Crit Care Res Grp, Brisbane, Australia
[2] Univ Queensland, Fac Med, Brisbane, Australia
[3] Prince Charles Hosp, Physiotherapy Dept, Brisbane, Australia
[4] Univ Queensland, Sch Dent, Brisbane, Australia
[5] Caboolture Hosp, Dept Mental Hlth, Metro North Mental Hlth, Caboolture, Australia
[6] Queensland Univ Technol, Sch Clin Sci, Brisbane, Australia
[7] Qld Univ Technol, Menzies Sch Hlth Res, Brisbane, Australia
[8] Qld Univ Technol, Fac Hlth, Brisbane, Australia
[9] St Andrews War Mem Hosp, Intens Care Unit, Brisbane, Australia
关键词
Alarms; Intensive care; Noise; Patient monitor; Sound; Sound reduction; NOISE; SLEEP; ENVIRONMENT;
D O I
10.1016/j.aucc.2024.02.011
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Background: ICU outcomes are continuing to improve. However, this has not been matched by similar improvements of the ICU bedspace environment, which can detrimentally impact on patient outcomes. Excessive sound and noise, especially, has been linked with adverse and potentially preventable patient outcomes and staff errors. There are many sources of sound in the ICU, with alarms from bedside equipment frequently listed as a main source. The number of alarms is increasing in parallel with the introduction of new and more sophisticated technologies to monitor and support patients. However, most alarms are not accurate or critical and are commonly ignored by staff. Objective: The objective of this study was to evaluate the impact of a sound reduction bundle on sound levels, number of alarms, and patients' experience and perceived quality of sleep in the ICU. Methods: This was a pre-post, quasi-experimental study investigating the impact of three study interventions implemented sequentially (staff education, visual warnings when sound levels exceeded the preset levels, and monitor alarm reconfigurations). Effects of staff education were evaluated using pre- education and post-education questionnaires, and the impact on patients was evaluated via self-report questionnaires. A sound-level monitor was used to evaluate changes in sound levels between interventions. Alarm audits were completed before and after alarm reconfiguration. Results: Staff knowledge improved; however, sound levels did not change across interventions. The number of monthly monitor alarms reduced from 600,452 to 115,927. No significant differences were found in patients' subjective rating of their experience and sleep. Conclusion: The interventions did not lead to a sound-level reduction; however, there was a large reduction in ICU monitor alarms without any alarm-related adverse events. As the sources of sound are diverse, multidimensional interventions, including staff education, alarm management solutions, and environmental redesign, are likely to be required to achieve a relevant, lasting, and significant sound reduction. (c) 2024 Australian College of Critical Care Nurses Ltd. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:716 / 726
页数:11
相关论文
共 50 条
  • [21] Noise levels in neonatal intensive care unit and use of sound absorbing panel in the isolette
    Altuncu, E.
    Akman, I.
    Kulekci, S.
    Akdas, F.
    Bilgen, H.
    Ozek, E.
    INTERNATIONAL JOURNAL OF PEDIATRIC OTORHINOLARYNGOLOGY, 2009, 73 (07) : 951 - 953
  • [22] Effect of nocturnal sound reduction on the incidence of delirium in intensive care unit patients: An interrupted time series analysis
    van de Pol, Ineke
    van Iterson, Mat
    Maaskant, Jolanda
    INTENSIVE AND CRITICAL CARE NURSING, 2017, 41 : 18 - 25
  • [23] Sound in Time: An observational study to identify the sources of sound and their relative contribution to the sound environment of an intensive care unit
    Dawson, Deborah
    Barham, Richard
    Hamilton, Mark
    Philips, Barbara
    APPLIED ACOUSTICS, 2022, 188
  • [24] Reduction of noise in the neonatal intensive care unit using sound-activated noise meters
    Wang, D.
    Aubertin, C.
    Barrowman, N.
    Moreau, K.
    Dunn, S.
    Harrold, J.
    ARCHIVES OF DISEASE IN CHILDHOOD-FETAL AND NEONATAL EDITION, 2014, 99 (06): : F515 - F516
  • [25] Sound levels in a neonatal intensive care unit significantly exceeded recommendations, especially inside incubators
    Parra, Johanna
    de Suremain, Aurelie
    Audeoud, Frederique Berne
    Ego, Anne
    Debillon, Thierry
    ACTA PAEDIATRICA, 2017, 106 (12) : 1909 - 1914
  • [26] Sound and Light Levels in a General Intensive Care Unit Without Windows to Provide Natural Light
    Lucchini, Alberto
    Giani, Marco
    Ferrari, Katia
    Di Maria, Stefania
    Galimberti, Giulia
    Zorz, Alessandra
    Iozzo, Pasquale
    Elli, Stefano
    Fumagalli, Roberto
    Bambi, Stefano
    DIMENSIONS OF CRITICAL CARE NURSING, 2023, 42 (02) : 115 - 123
  • [27] The Influence of Neonatal Intensive Care Unit Design on Sound Level
    Chen, Hsin-Li
    Chen, Chao-Huei
    Wu, Chih-Chao
    Huang, Hsiu-Jung
    Wang, Teh-Ming
    Hsu, Chia-Chi
    PEDIATRICS AND NEONATOLOGY, 2009, 50 (06): : 270 - 274
  • [28] Introduction to monitoring in the neurological intensive care unit and its future impact
    Smith, WS
    Aminoff, MJ
    NEUROLOGIST, 2000, 6 (02) : 83 - 97
  • [29] Sustainable reduction in sound levels on intensive care units through noise management - an implementation study
    Sandra Witek
    Claudia Schmoor
    Fabian Montigel
    Birgit Grotejohann
    Sven Ziegler
    BMC Health Services Research, 25 (1)
  • [30] An investigation of light and sound levels on intensive care units in China
    Hu, Rong-fang
    Hegadoren, Kathleen M.
    Wang, Xiao-yan
    Jiang, Xiao-ying
    AUSTRALIAN CRITICAL CARE, 2016, 29 (02) : 62 - 67