Reduction of noise in the neonatal intensive care unit using sound-activated noise meters

被引:23
|
作者
Wang, D. [1 ]
Aubertin, C. [1 ]
Barrowman, N. [2 ]
Moreau, K. [2 ]
Dunn, S. [1 ,3 ]
Harrold, J. [1 ,2 ,3 ]
机构
[1] Childrens Hosp Eastern Ontario, Ottawa, ON K1H 8L1, Canada
[2] Childrens Hosp Eastern Ontario, Res Inst, Ottawa, ON K1H 8L1, Canada
[3] Univ Ottawa, Ottawa, ON, Canada
关键词
D O I
10.1136/archdischild-2014-306490
中图分类号
R72 [儿科学];
学科分类号
100202 ;
摘要
Objectives To determine if sound-activated noise meters providing direct audit and visual feedback can reduce sound levels in a level 3 neonatal intensive care unit (NICU). Design/methods Sound levels (in dB) were compared between a 2-month period with noise meters present but without visual signal fluctuation and a subsequent 2 months with the noise meters providing direct audit and visual feedback. Results There was a significant increase in the percentage of time the sound level in the NICU was below 50 dB across all patient care areas (9.9%, 8.9% and 7.3%). This improvement was not observed in the desk area where there are no admitted patients. There was no change in the percentage of time the NICU was below 45 or 55 dB. Conclusions Sound-activated noise meters seem effective in reducing sound levels in patient care areas. Conversations may have moved to non-patient care areas preventing a similar change there.
引用
下载
收藏
页码:F515 / F516
页数:2
相关论文
共 50 条
  • [1] Using Sound-Activated Noise Meters to Reduce Noise in Neonatal Intensive Care Units
    Holt, Hailee
    Weber, Abby
    NURSING RESEARCH, 2019, 68 (02) : E152 - E152
  • [2] The Effect of Noise Meters Giving Visual and Auditory Alarms Used on Reducing Noise in Neonatal Intensive Care Unit
    Balci, Serap
    Incekar, Mujde Calikusu
    Tastekin, Ayhan
    JOURNAL OF PEDIATRIC RESEARCH, 2021, 8 (04) : 456 - 461
  • [3] Noise Reduction in the Neonatal Intensive Care Unit: A Quality Improvement Initiative
    Ahamed, Mohamed Farooq
    Campbell, Deborah
    Horan, Susan
    Rosen, Orna
    AMERICAN JOURNAL OF MEDICAL QUALITY, 2018, 33 (02) : 177 - 184
  • [4] EVALUATION OF NOISE IN THE NEONATAL INTENSIVE CARE UNIT
    Teixeira, Alessandra
    Fialho, Flavia Andrade
    Avila Vargas, Ieda Maria
    de Souza Martins, Katia Cristina
    Machado, Roberto Vale
    Correia, Maria Efigenia
    REVISTA CUIDARTE, 2011, 2 (01) : 114 - 118
  • [5] Analysis of noise in a neonatal intensive care unit
    Guimaraes, H
    Oliveira, AM
    Spratley, J
    Mateus, M
    dOrey, C
    Coelho, JL
    Souto, A
    Santos, NT
    ARCHIVES DE PEDIATRIE, 1996, 3 (11): : 1065 - 1068
  • [6] Repercussion of noise in the neonatal intensive care unit
    Grecco, Gabriela Menossi
    Tsunemi, Miriam Harumi
    Ferreira Gomes Balieiro, Maria Magda
    Kakehashi, Tereza Yoshiko
    Pinheiro, Eliana Moreira
    ACTA PAULISTA DE ENFERMAGEM, 2013, 26 (01) : 1 - 7
  • [7] Evaluation of noise in the neonatal intensive care unit
    Benini, F
    Magnavita, V
    Lago, P
    Arslan, E
    Pisan, P
    AMERICAN JOURNAL OF PERINATOLOGY, 1996, 13 (01) : 37 - 41
  • [8] Establishing a Contextualized Intervention Program for Noise Reduction in a Neonatal Intensive Care Unit
    Kose, Semra
    Sabetsarvestani, Raheleh
    Geckil, Emine
    Ozkilicaslan, Fatma Tokan
    Karaarslan, Fatih
    Tosun, Esra Erturk
    Altunhan, Huseyin
    HERD-HEALTH ENVIRONMENTS RESEARCH & DESIGN JOURNAL, 2024,
  • [9] Examining the effects of a targeted noise reduction program in a neonatal intensive care unit
    Wang, D.
    Aubertin, C.
    Barrowman, N.
    Moreau, K.
    Dunn, S.
    Harrold, J.
    ARCHIVES OF DISEASE IN CHILDHOOD-FETAL AND NEONATAL EDITION, 2014, 99 (03): : F203 - F208
  • [10] Noise levels in neonatal intensive care unit and use of sound absorbing panel in the isolette
    Altuncu, E.
    Akman, I.
    Kulekci, S.
    Akdas, F.
    Bilgen, H.
    Ozek, E.
    INTERNATIONAL JOURNAL OF PEDIATRIC OTORHINOLARYNGOLOGY, 2009, 73 (07) : 951 - 953